  "schema_version": 1,
  "inventory_kind": "objective_pool",
  "installed_hardware": false,
  "compatibility_status": "not_verified",
  "source": {
    "file_name": "ZEISSThread M27.docx",
    "sha256": "5fadd6249bba1aab08f40120d580a1fac1403353166b0d5615459068cffbc9c9",
    "compiled_by": "Jari Korhonen",
    "date_text": "020426",
    "date_iso": null,
    "working_distance_unit": "mm"
  },
  "families": [
    {
      "id": "zeiss",
      "label": "ZEISS",
      "mount_text": "Thread M27/0.75",
      "source_heading": "ZEISS\tThread M27/0.75"
    },
    {
      "id": "leica",
      "label": "Leica",
      "mount_text": "Thread M25",
      "source_heading": "Leica \tThread M25"
    },
    {
      "id": "olympus",
      "label": "OLYMPUS, Japan",
      "mount_text": "thread 20 (as written)",
      "source_heading": "OLYMPUS, Japan\n-tubus length 160, thread 20"
    },
    {
      "id": "incucyte",
      "label": "IncuCyte by ESSEN BIOSCIENCE",
      "mount_text": "thread -23 (as written)",
      "source_heading": "IncuCyte by ESSEN BIOSCIENCE\n-thread -23"
    },
    {
      "id": "nikon",
      "label": "Nikon, Japan",
      "mount_text": null,
      "source_heading": "Nikon, Japan"
    }
  ],
  "filters": {
    "kind": [
      {
        "id": "objective",
        "label": "Objective"
      },
      {
        "id": "calibration",
        "label": "Calibration item"
      }
    ],
    "immersion": [
      {
        "id": "dry",
        "label": "Dry"
      },
      {
        "id": "water",
        "label": "Water immersion"
      },
      {
        "id": "oil",
        "label": "Oil immersion"
      },
      {
        "id": "water_dipping",
        "label": "Water dipping"
      },
      {
        "id": "universal",
        "label": "Universal immersion"
      },
      {
        "id": "not_recorded",
        "label": "Not recorded"
      }
    ],
    "condition": [
      {
        "id": "not_assessed",
        "label": "Not assessed"
      },
      {
        "id": "reported_issue",
        "label": "Reported problem"
      },
      {
        "id": "reported_unusable",
        "label": "Reported unusable"
      }
    ],
    "availability": [
      {
        "id": "unconfirmed",
        "label": "Availability unconfirmed"
      }
    ]
  },
  "items": [
    {
      "id": "pool-zeiss-441371-9970",
      "family_id": "zeiss",
      "kind": "objective",
      "name": "LD Plan-NEOFLUAR 63x/0.75 Ph2 Korr",
      "product_code": "441371-9970",
      "magnification": 63,
      "numerical_aperture_text": "0.75",
      "immersion": "dry",
      "working_distance_text": "0,75",
      "condition": "not_assessed",
      "condition_note": null,
      "availability": "unconfirmed",
      "location": null,
      "quantity": null,
      "inspection": null,
      "source_page": 1,
      "source_text": "441371-9970 LD Plan-NEOFLUAR 63x/0.75 Ph2 Korr\tWD 0,75",
      "order": 0,
      "family_label": "ZEISS",
      "mount_label": "Thread M27/0.75",
      "source_heading": "ZEISS\tThread M27/0.75",
      "magnification_label": "63x",
      "kind_label": "Objective",
      "immersion_label": "Dry",
      "condition_label": "Not assessed",
      "availability_label": "Availability unconfirmed",
      "has_reported_problem": false,
      "condition_description": "No problem noted in the source; this is not a serviceability check.",
      "search_text": "pool-zeiss-441371-9970 ZEISS LD Plan-NEOFLUAR 63x/0.75 Ph2 Korr 441371-9970 441371-9970 LD Plan-NEOFLUAR 63x/0.75 Ph2 Korr\tWD 0,75 Thread M27/0.75 Dry Objective Not assessed 63x ",
      "enquiry": "Hi AIC Turku team,\nCould you check whether this item is available and suitable for my experiment?\nItem: ZEISS LD Plan-NEOFLUAR 63x/0.75 Ph2 Korr\nPool record: pool-zeiss-441371-9970; product code: 441371-9970\nRecorded condition: Not assessed\nCondition note: No problem noted in the source; this is not a serviceability check.\nAvailability: Availability unconfirmed\nMicroscope: [please enter]\nExperiment and planned date: [please enter]\nPlease confirm compatibility and arrange any installation. Thank you."
    },
    {
      "id": "pool-zeiss-44-03-50",
      "family_id": "zeiss",
      "kind": "objective",
      "name": "Plan-NEOFLUAR 40x/0.75",
      "product_code": "44 03 50",
      "magnification": 40,
      "numerical_aperture_text": "0.75",
      "immersion": "dry",
      "working_distance_text": "0.71",
      "condition": "not_assessed",
      "condition_note": null,
      "availability": "unconfirmed",
      "location": null,
      "quantity": null,
      "inspection": null,
      "source_page": 1,
      "source_text": "44 03 50 Plan-NEOFLUAR 40x/0.75\t\tWD 0.71",
      "order": 1,
      "family_label": "ZEISS",
      "mount_label": "Thread M27/0.75",
      "source_heading": "ZEISS\tThread M27/0.75",
      "magnification_label": "40x",
      "kind_label": "Objective",
      "immersion_label": "Dry",
      "condition_label": "Not assessed",
      "availability_label": "Availability unconfirmed",
      "has_reported_problem": false,
      "condition_description": "No problem noted in the source; this is not a serviceability check.",
      "search_text": "pool-zeiss-44-03-50 ZEISS Plan-NEOFLUAR 40x/0.75 44 03 50 44 03 50 Plan-NEOFLUAR 40x/0.75\t\tWD 0.71 Thread M27/0.75 Dry Objective Not assessed 40x ",
      "enquiry": "Hi AIC Turku team,\nCould you check whether this item is available and suitable for my experiment?\nItem: ZEISS Plan-NEOFLUAR 40x/0.75\nPool record: pool-zeiss-44-03-50; product code: 44 03 50\nRecorded condition: Not assessed\nCondition note: No problem noted in the source; this is not a serviceability check.\nAvailability: Availability unconfirmed\nMicroscope: [please enter]\nExperiment and planned date: [please enter]\nPlease confirm compatibility and arrange any installation. Thank you."
    },
    {
      "id": "pool-zeiss-441351-9970",
      "family_id": "zeiss",
      "kind": "objective",
      "name": "LD Plan-NEOFLUAR 40x/0.6 Ph2 Korr",
      "product_code": "441351-9970",
      "magnification": 40,
      "numerical_aperture_text": "0.6",
      "immersion": "dry",
      "working_distance_text": "2,9 at cover glass 0,75",
      "condition": "not_assessed",
      "condition_note": null,
      "availability": "unconfirmed",
      "location": null,
      "quantity": null,
      "inspection": null,
      "source_page": 1,
      "source_text": "441351-9970 LD Plan-NEOFLUAR 40x/0.6 Ph2 Korr\tWD 2,9 at cover glass 0,75",
      "order": 2,
      "family_label": "ZEISS",
      "mount_label": "Thread M27/0.75",
      "source_heading": "ZEISS\tThread M27/0.75",
      "magnification_label": "40x",
      "kind_label": "Objective",
      "immersion_label": "Dry",
      "condition_label": "Not assessed",
      "availability_label": "Availability unconfirmed",
      "has_reported_problem": false,
      "condition_description": "No problem noted in the source; this is not a serviceability check.",
      "search_text": "pool-zeiss-441351-9970 ZEISS LD Plan-NEOFLUAR 40x/0.6 Ph2 Korr 441351-9970 441351-9970 LD Plan-NEOFLUAR 40x/0.6 Ph2 Korr\tWD 2,9 at cover glass 0,75 Thread M27/0.75 Dry Objective Not assessed 40x ",
      "enquiry": "Hi AIC Turku team,\nCould you check whether this item is available and suitable for my experiment?\nItem: ZEISS LD Plan-NEOFLUAR 40x/0.6 Ph2 Korr\nPool record: pool-zeiss-441351-9970; product code: 441351-9970\nRecorded condition: Not assessed\nCondition note: No problem noted in the source; this is not a serviceability check.\nAvailability: Availability unconfirmed\nMicroscope: [please enter]\nExperiment and planned date: [please enter]\nPlease confirm compatibility and arrange any installation. Thank you."
    },
    {
      "id": "pool-zeiss-420650-9901",
      "family_id": "zeiss",
      "kind": "objective",
      "name": "Plan-APOCHROMAT 20x/0.8",
      "product_code": "420650-9901",
      "magnification": 20,
      "numerical_aperture_text": "0.8",
      "immersion": "dry",
      "working_distance_text": "0.55",
      "condition": "not_assessed",
      "condition_note": null,
      "availability": "unconfirmed",
      "location": null,
      "quantity": null,
      "inspection": null,
      "source_page": 1,
      "source_text": "420650-9901 Plan-APOCHROMAT 20x/0.8\t\tWD 0.55",
      "order": 3,
      "family_label": "ZEISS",
      "mount_label": "Thread M27/0.75",
      "source_heading": "ZEISS\tThread M27/0.75",
      "magnification_label": "20x",
      "kind_label": "Objective",
      "immersion_label": "Dry",
      "condition_label": "Not assessed",
      "availability_label": "Availability unconfirmed",
      "has_reported_problem": false,
      "condition_description": "No problem noted in the source; this is not a serviceability check.",
      "search_text": "pool-zeiss-420650-9901 ZEISS Plan-APOCHROMAT 20x/0.8 420650-9901 420650-9901 Plan-APOCHROMAT 20x/0.8\t\tWD 0.55 Thread M27/0.75 Dry Objective Not assessed 20x ",
      "enquiry": "Hi AIC Turku team,\nCould you check whether this item is available and suitable for my experiment?\nItem: ZEISS Plan-APOCHROMAT 20x/0.8\nPool record: pool-zeiss-420650-9901; product code: 420650-9901\nRecorded condition: Not assessed\nCondition note: No problem noted in the source; this is not a serviceability check.\nAvailability: Availability unconfirmed\nMicroscope: [please enter]\nExperiment and planned date: [please enter]\nPlease confirm compatibility and arrange any installation. Thank you."
    },
    {
      "id": "pool-zeiss-1006-592",
      "family_id": "zeiss",
      "kind": "objective",
      "name": "LD A-Plan 20x/0.30 Ph1 Var1",
      "product_code": "1006-592",
      "magnification": 20,
      "numerical_aperture_text": "0.30",
      "immersion": "dry",
      "working_distance_text": "4,3",
      "condition": "not_assessed",
      "condition_note": null,
      "availability": "unconfirmed",
      "location": null,
      "quantity": null,
      "inspection": null,
      "source_page": 1,
      "source_text": "1006-592 LD A-Plan 20x/0.30 Ph1 Var1\t\tWD 4,3",
      "order": 4,
      "family_label": "ZEISS",
      "mount_label": "Thread M27/0.75",
      "source_heading": "ZEISS\tThread M27/0.75",
      "magnification_label": "20x",
      "kind_label": "Objective",
      "immersion_label": "Dry",
      "condition_label": "Not assessed",
      "availability_label": "Availability unconfirmed",
      "has_reported_problem": false,
      "condition_description": "No problem noted in the source; this is not a serviceability check.",
      "search_text": "pool-zeiss-1006-592 ZEISS LD A-Plan 20x/0.30 Ph1 Var1 1006-592 1006-592 LD A-Plan 20x/0.30 Ph1 Var1\t\tWD 4,3 Thread M27/0.75 Dry Objective Not assessed 20x ",
      "enquiry": "Hi AIC Turku team,\nCould you check whether this item is available and suitable for my experiment?\nItem: ZEISS LD A-Plan 20x/0.30 Ph1 Var1\nPool record: pool-zeiss-1006-592; product code: 1006-592\nRecorded condition: Not assessed\nCondition note: No problem noted in the source; this is not a serviceability check.\nAvailability: Availability unconfirmed\nMicroscope: [please enter]\nExperiment and planned date: [please enter]\nPlease confirm compatibility and arrange any installation. Thank you."
    },
    {
      "id": "pool-zeiss-44-03-30",
      "family_id": "zeiss",
      "kind": "objective",
      "name": "Plan-NEOFLUAR 10x/0.30",
      "product_code": "44 03 30",
      "magnification": 10,
      "numerical_aperture_text": "0.30",
      "immersion": "dry",
      "working_distance_text": "5,2",
      "condition": "not_assessed",
      "condition_note": null,
      "availability": "unconfirmed",
      "location": null,
      "quantity": null,
      "inspection": null,
      "source_page": 1,
      "source_text": "44 03 30 Plan-NEOFLUAR 10x/0.30\t\tWD 5,2",
      "order": 5,
      "family_label": "ZEISS",
      "mount_label": "Thread M27/0.75",
      "source_heading": "ZEISS\tThread M27/0.75",
      "magnification_label": "10x",
      "kind_label": "Objective",
      "immersion_label": "Dry",
      "condition_label": "Not assessed",
      "availability_label": "Availability unconfirmed",
      "has_reported_problem": false,
      "condition_description": "No problem noted in the source; this is not a serviceability check.",
      "search_text": "pool-zeiss-44-03-30 ZEISS Plan-NEOFLUAR 10x/0.30 44 03 30 44 03 30 Plan-NEOFLUAR 10x/0.30\t\tWD 5,2 Thread M27/0.75 Dry Objective Not assessed 10x ",
      "enquiry": "Hi AIC Turku team,\nCould you check whether this item is available and suitable for my experiment?\nItem: ZEISS Plan-NEOFLUAR 10x/0.30\nPool record: pool-zeiss-44-03-30; product code: 44 03 30\nRecorded condition: Not assessed\nCondition note: No problem noted in the source; this is not a serviceability check.\nAvailability: Availability unconfirmed\nMicroscope: [please enter]\nExperiment and planned date: [please enter]\nPlease confirm compatibility and arrange any installation. Thank you."
    },
    {
      "id": "pool-zeiss-420340-9901",
      "family_id": "zeiss",
      "kind": "objective",
      "name": "EC Plan-NEOFLUAR 10x/0.3",
      "product_code": "420340-9901",
      "magnification": 10,
      "numerical_aperture_text": "0.3",
      "immersion": "dry",
      "working_distance_text": "5,2",
      "condition": "not_assessed",
      "condition_note": null,
      "availability": "unconfirmed",
      "location": null,
      "quantity": null,
      "inspection": null,
      "source_page": 1,
      "source_text": "420340-9901 EC Plan-NEOFLUAR 10x/0.3\t\tWD 5,2",
      "order": 6,
      "family_label": "ZEISS",
      "mount_label": "Thread M27/0.75",
      "source_heading": "ZEISS\tThread M27/0.75",
      "magnification_label": "10x",
      "kind_label": "Objective",
      "immersion_label": "Dry",
      "condition_label": "Not assessed",
      "availability_label": "Availability unconfirmed",
      "has_reported_problem": false,
      "condition_description": "No problem noted in the source; this is not a serviceability check.",
      "search_text": "pool-zeiss-420340-9901 ZEISS EC Plan-NEOFLUAR 10x/0.3 420340-9901 420340-9901 EC Plan-NEOFLUAR 10x/0.3\t\tWD 5,2 Thread M27/0.75 Dry Objective Not assessed 10x ",
      "enquiry": "Hi AIC Turku team,\nCould you check whether this item is available and suitable for my experiment?\nItem: ZEISS EC Plan-NEOFLUAR 10x/0.3\nPool record: pool-zeiss-420340-9901; product code: 420340-9901\nRecorded condition: Not assessed\nCondition note: No problem noted in the source; this is not a serviceability check.\nAvailability: Availability unconfirmed\nMicroscope: [please enter]\nExperiment and planned date: [please enter]\nPlease confirm compatibility and arrange any installation. Thank you."
    },
    {
      "id": "pool-zeiss-422320-9960",
      "family_id": "zeiss",
      "kind": "objective",
      "name": "EC Epiplan-NEOFLUAR 2.5x/0.06 HD",
      "product_code": "422320-9960",
      "magnification": 2.5,
      "numerical_aperture_text": "0.06",
      "immersion": "dry",
      "working_distance_text": "15,1",
      "condition": "not_assessed",
      "condition_note": null,
      "availability": "unconfirmed",
      "location": null,
      "quantity": null,
      "inspection": null,
      "source_page": 1,
      "source_text": "422320-9960 EC Epiplan-NEOFLUAR 2.5x/0.06 HD\tWD 15,1",
      "order": 7,
      "family_label": "ZEISS",
      "mount_label": "Thread M27/0.75",
      "source_heading": "ZEISS\tThread M27/0.75",
      "magnification_label": "2.5x",
      "kind_label": "Objective",
      "immersion_label": "Dry",
      "condition_label": "Not assessed",
      "availability_label": "Availability unconfirmed",
      "has_reported_problem": false,
      "condition_description": "No problem noted in the source; this is not a serviceability check.",
      "search_text": "pool-zeiss-422320-9960 ZEISS EC Epiplan-NEOFLUAR 2.5x/0.06 HD 422320-9960 422320-9960 EC Epiplan-NEOFLUAR 2.5x/0.06 HD\tWD 15,1 Thread M27/0.75 Dry Objective Not assessed 2.5x ",
      "enquiry": "Hi AIC Turku team,\nCould you check whether this item is available and suitable for my experiment?\nItem: ZEISS EC Epiplan-NEOFLUAR 2.5x/0.06 HD\nPool record: pool-zeiss-422320-9960; product code: 422320-9960\nRecorded condition: Not assessed\nCondition note: No problem noted in the source; this is not a serviceability check.\nAvailability: Availability unconfirmed\nMicroscope: [please enter]\nExperiment and planned date: [please enter]\nPlease confirm compatibility and arrange any installation. Thank you."
    },
    {
      "id": "pool-zeiss-420300-9900",
      "family_id": "zeiss",
      "kind": "objective",
      "name": "EC Plan-NEOFLUAR 1x/0.025",
      "product_code": "420300-9900",
      "magnification": 1,
      "numerical_aperture_text": "0.025",
      "immersion": "dry",
      "working_distance_text": "2,9",
      "condition": "not_assessed",
      "condition_note": null,
      "availability": "unconfirmed",
      "location": null,
      "quantity": null,
      "inspection": null,
      "source_page": 1,
      "source_text": "420300-9900 EC Plan-NEOFLUAR 1x/0.025\t\tWD 2,9",
      "order": 8,
      "family_label": "ZEISS",
      "mount_label": "Thread M27/0.75",
      "source_heading": "ZEISS\tThread M27/0.75",
      "magnification_label": "1x",
      "kind_label": "Objective",
      "immersion_label": "Dry",
      "condition_label": "Not assessed",
      "availability_label": "Availability unconfirmed",
      "has_reported_problem": false,
      "condition_description": "No problem noted in the source; this is not a serviceability check.",
      "search_text": "pool-zeiss-420300-9900 ZEISS EC Plan-NEOFLUAR 1x/0.025 420300-9900 420300-9900 EC Plan-NEOFLUAR 1x/0.025\t\tWD 2,9 Thread M27/0.75 Dry Objective Not assessed 1x ",
      "enquiry": "Hi AIC Turku team,\nCould you check whether this item is available and suitable for my experiment?\nItem: ZEISS EC Plan-NEOFLUAR 1x/0.025\nPool record: pool-zeiss-420300-9900; product code: 420300-9900\nRecorded condition: Not assessed\nCondition note: No problem noted in the source; this is not a serviceability check.\nAvailability: Availability unconfirmed\nMicroscope: [please enter]\nExperiment and planned date: [please enter]\nPlease confirm compatibility and arrange any installation. Thank you."
    },
    {
      "id": "pool-zeiss-421787-9970",
      "family_id": "zeiss",
      "kind": "objective",
      "name": "C-APOCHROMAT 63x/1.2 W Korr UV-VIS-IR",
      "product_code": "421787–9970",
      "magnification": 63,
      "numerical_aperture_text": "1.2",
      "immersion": "water",
      "working_distance_text": "0.28",
      "condition": "not_assessed",
      "condition_note": null,
      "availability": "unconfirmed",
      "location": null,
      "quantity": null,
      "inspection": null,
      "source_page": 1,
      "source_text": "421787–9970 C-APOCHROMAT 63x/1.2 W Korr UV-VIS-IR \tWD 0.28",
      "order": 9,
      "family_label": "ZEISS",
      "mount_label": "Thread M27/0.75",
      "source_heading": "ZEISS\tThread M27/0.75",
      "magnification_label": "63x",
      "kind_label": "Objective",
      "immersion_label": "Water immersion",
      "condition_label": "Not assessed",
      "availability_label": "Availability unconfirmed",
      "has_reported_problem": false,
      "condition_description": "No problem noted in the source; this is not a serviceability check.",
      "search_text": "pool-zeiss-421787-9970 ZEISS C-APOCHROMAT 63x/1.2 W Korr UV-VIS-IR 421787–9970 421787–9970 C-APOCHROMAT 63x/1.2 W Korr UV-VIS-IR \tWD 0.28 Thread M27/0.75 Water immersion Objective Not assessed 63x ",
      "enquiry": "Hi AIC Turku team,\nCould you check whether this item is available and suitable for my experiment?\nItem: ZEISS C-APOCHROMAT 63x/1.2 W Korr UV-VIS-IR\nPool record: pool-zeiss-421787-9970; product code: 421787–9970\nRecorded condition: Not assessed\nCondition note: No problem noted in the source; this is not a serviceability check.\nAvailability: Availability unconfirmed\nMicroscope: [please enter]\nExperiment and planned date: [please enter]\nPlease confirm compatibility and arrange any installation. Thank you."
    },
    {
      "id": "pool-zeiss-421887-9970",
      "family_id": "zeiss",
      "kind": "objective",
      "name": "LD C-APOCHROMAT 63x/1.15 W Korr UV-VIS-IR",
      "product_code": "421887–9970",
      "magnification": 63,
      "numerical_aperture_text": "1.15",
      "immersion": "water",
      "working_distance_text": "0,60",
      "condition": "not_assessed",
      "condition_note": null,
      "availability": "unconfirmed",
      "location": null,
      "quantity": null,
      "inspection": null,
      "source_page": 1,
      "source_text": "421887–9970 LD C-APOCHROMAT 63x/1.15 W Korr UV-VIS-IR\tWD 0,60",
      "order": 10,
      "family_label": "ZEISS",
      "mount_label": "Thread M27/0.75",
      "source_heading": "ZEISS\tThread M27/0.75",
      "magnification_label": "63x",
      "kind_label": "Objective",
      "immersion_label": "Water immersion",
      "condition_label": "Not assessed",
      "availability_label": "Availability unconfirmed",
      "has_reported_problem": false,
      "condition_description": "No problem noted in the source; this is not a serviceability check.",
      "search_text": "pool-zeiss-421887-9970 ZEISS LD C-APOCHROMAT 63x/1.15 W Korr UV-VIS-IR 421887–9970 421887–9970 LD C-APOCHROMAT 63x/1.15 W Korr UV-VIS-IR\tWD 0,60 Thread M27/0.75 Water immersion Objective Not assessed 63x ",
      "enquiry": "Hi AIC Turku team,\nCould you check whether this item is available and suitable for my experiment?\nItem: ZEISS LD C-APOCHROMAT 63x/1.15 W Korr UV-VIS-IR\nPool record: pool-zeiss-421887-9970; product code: 421887–9970\nRecorded condition: Not assessed\nCondition note: No problem noted in the source; this is not a serviceability check.\nAvailability: Availability unconfirmed\nMicroscope: [please enter]\nExperiment and planned date: [please enter]\nPlease confirm compatibility and arrange any installation. Thank you."
    },
    {
      "id": "pool-zeiss-440782-9902",
      "family_id": "zeiss",
      "kind": "objective",
      "name": "Plan-APOCHROMAT 100x/1.4 Oil DIC",
      "product_code": "440782-9902",
      "magnification": 100,
      "numerical_aperture_text": "1.4",
      "immersion": "oil",
      "working_distance_text": "0,17",
      "condition": "not_assessed",
      "condition_note": null,
      "availability": "unconfirmed",
      "location": null,
      "quantity": null,
      "inspection": null,
      "source_page": 1,
      "source_text": "440782-9902 Plan-APOCHROMAT 100x/1.4 Oil DIC\tWD 0,17",
      "order": 11,
      "family_label": "ZEISS",
      "mount_label": "Thread M27/0.75",
      "source_heading": "ZEISS\tThread M27/0.75",
      "magnification_label": "100x",
      "kind_label": "Objective",
      "immersion_label": "Oil immersion",
      "condition_label": "Not assessed",
      "availability_label": "Availability unconfirmed",
      "has_reported_problem": false,
      "condition_description": "No problem noted in the source; this is not a serviceability check.",
      "search_text": "pool-zeiss-440782-9902 ZEISS Plan-APOCHROMAT 100x/1.4 Oil DIC 440782-9902 440782-9902 Plan-APOCHROMAT 100x/1.4 Oil DIC\tWD 0,17 Thread M27/0.75 Oil immersion Objective Not assessed 100x ",
      "enquiry": "Hi AIC Turku team,\nCould you check whether this item is available and suitable for my experiment?\nItem: ZEISS Plan-APOCHROMAT 100x/1.4 Oil DIC\nPool record: pool-zeiss-440782-9902; product code: 440782-9902\nRecorded condition: Not assessed\nCondition note: No problem noted in the source; this is not a serviceability check.\nAvailability: Availability unconfirmed\nMicroscope: [please enter]\nExperiment and planned date: [please enter]\nPlease confirm compatibility and arrange any installation. Thank you."
    },
    {
      "id": "pool-zeiss-44-04-61",
      "family_id": "zeiss",
      "kind": "objective",
      "name": "Plan-NEOFLUAR 63x/1.25 Oil PH3",
      "product_code": "44 04 61",
      "magnification": 63,
      "numerical_aperture_text": "1.25",
      "immersion": "oil",
      "working_distance_text": "0,10",
      "condition": "not_assessed",
      "condition_note": null,
      "availability": "unconfirmed",
      "location": null,
      "quantity": null,
      "inspection": null,
      "source_page": 1,
      "source_text": "44 04 61 Plan-NEOFLUAR 63x/1.25 Oil PH3\t\tWD 0,10",
      "order": 12,
      "family_label": "ZEISS",
      "mount_label": "Thread M27/0.75",
      "source_heading": "ZEISS\tThread M27/0.75",
      "magnification_label": "63x",
      "kind_label": "Objective",
      "immersion_label": "Oil immersion",
      "condition_label": "Not assessed",
      "availability_label": "Availability unconfirmed",
      "has_reported_problem": false,
      "condition_description": "No problem noted in the source; this is not a serviceability check.",
      "search_text": "pool-zeiss-44-04-61 ZEISS Plan-NEOFLUAR 63x/1.25 Oil PH3 44 04 61 44 04 61 Plan-NEOFLUAR 63x/1.25 Oil PH3\t\tWD 0,10 Thread M27/0.75 Oil immersion Objective Not assessed 63x ",
      "enquiry": "Hi AIC Turku team,\nCould you check whether this item is available and suitable for my experiment?\nItem: ZEISS Plan-NEOFLUAR 63x/1.25 Oil PH3\nPool record: pool-zeiss-44-04-61; product code: 44 04 61\nRecorded condition: Not assessed\nCondition note: No problem noted in the source; this is not a serviceability check.\nAvailability: Availability unconfirmed\nMicroscope: [please enter]\nExperiment and planned date: [please enter]\nPlease confirm compatibility and arrange any installation. Thank you."
    },
    {
      "id": "pool-zeiss-44-07-60",
      "family_id": "zeiss",
      "kind": "objective",
      "name": "Plan-APOCHROMAT 63x/1.4 Oil",
      "product_code": "44 07 60 (1100-829)",
      "magnification": 63,
      "numerical_aperture_text": "1.4",
      "immersion": "oil",
      "working_distance_text": "0,19",
      "condition": "not_assessed",
      "condition_note": null,
      "availability": "unconfirmed",
      "location": null,
      "quantity": null,
      "inspection": null,
      "source_page": 1,
      "source_text": "44 07 60 (1100-829) Plan-APOCHROMAT 63x/1.4 Oil\tWD 0,19",
      "order": 13,
      "family_label": "ZEISS",
      "mount_label": "Thread M27/0.75",
      "source_heading": "ZEISS\tThread M27/0.75",
      "magnification_label": "63x",
      "kind_label": "Objective",
      "immersion_label": "Oil immersion",
      "condition_label": "Not assessed",
      "availability_label": "Availability unconfirmed",
      "has_reported_problem": false,
      "condition_description": "No problem noted in the source; this is not a serviceability check.",
      "search_text": "pool-zeiss-44-07-60 ZEISS Plan-APOCHROMAT 63x/1.4 Oil 44 07 60 (1100-829) 44 07 60 (1100-829) Plan-APOCHROMAT 63x/1.4 Oil\tWD 0,19 Thread M27/0.75 Oil immersion Objective Not assessed 63x ",
      "enquiry": "Hi AIC Turku team,\nCould you check whether this item is available and suitable for my experiment?\nItem: ZEISS Plan-APOCHROMAT 63x/1.4 Oil\nPool record: pool-zeiss-44-07-60; product code: 44 07 60 (1100-829)\nRecorded condition: Not assessed\nCondition note: No problem noted in the source; this is not a serviceability check.\nAvailability: Availability unconfirmed\nMicroscope: [please enter]\nExperiment and planned date: [please enter]\nPlease confirm compatibility and arrange any installation. Thank you."
    },
    {
      "id": "pool-zeiss-440762-9904",
      "family_id": "zeiss",
      "kind": "objective",
      "name": "Plan-APOCHROMAT 63x/1.4 Oil DIC",
      "product_code": "440762-9904",
      "magnification": 63,
      "numerical_aperture_text": "1.4",
      "immersion": "oil",
      "working_distance_text": "0,19",
      "condition": "not_assessed",
      "condition_note": null,
      "availability": "unconfirmed",
      "location": null,
      "quantity": null,
      "inspection": null,
      "source_page": 1,
      "source_text": "440762-9904 Plan-APOCHROMAT 63x/1.4 Oil DIC\tWD 0,19",
      "order": 14,
      "family_label": "ZEISS",
      "mount_label": "Thread M27/0.75",
      "source_heading": "ZEISS\tThread M27/0.75",
      "magnification_label": "63x",
      "kind_label": "Objective",
      "immersion_label": "Oil immersion",
      "condition_label": "Not assessed",
      "availability_label": "Availability unconfirmed",
      "has_reported_problem": false,
      "condition_description": "No problem noted in the source; this is not a serviceability check.",
      "search_text": "pool-zeiss-440762-9904 ZEISS Plan-APOCHROMAT 63x/1.4 Oil DIC 440762-9904 440762-9904 Plan-APOCHROMAT 63x/1.4 Oil DIC\tWD 0,19 Thread M27/0.75 Oil immersion Objective Not assessed 63x ",
      "enquiry": "Hi AIC Turku team,\nCould you check whether this item is available and suitable for my experiment?\nItem: ZEISS Plan-APOCHROMAT 63x/1.4 Oil DIC\nPool record: pool-zeiss-440762-9904; product code: 440762-9904\nRecorded condition: Not assessed\nCondition note: No problem noted in the source; this is not a serviceability check.\nAvailability: Availability unconfirmed\nMicroscope: [please enter]\nExperiment and planned date: [please enter]\nPlease confirm compatibility and arrange any installation. Thank you."
    },
    {
      "id": "pool-zeiss-1022-818",
      "family_id": "zeiss",
      "kind": "objective",
      "name": "Plan-NEOFLUAR 40x/1.3 Oil",
      "product_code": "1022-818 (1080-398)",
      "magnification": 40,
      "numerical_aperture_text": "1.3",
      "immersion": "oil",
      "working_distance_text": "0,21",
      "condition": "reported_issue",
      "condition_note": "Inner lenses with droplets!",
      "availability": "unconfirmed",
      "location": null,
      "quantity": null,
      "inspection": null,
      "source_page": 1,
      "source_text": "1022-818 (1080-398) Plan-NEOFLUAR 40x/1.3 Oil\tWD 0,21\nInner lenses with droplets!",
      "order": 15,
      "family_label": "ZEISS",
      "mount_label": "Thread M27/0.75",
      "source_heading": "ZEISS\tThread M27/0.75",
      "magnification_label": "40x",
      "kind_label": "Objective",
      "immersion_label": "Oil immersion",
      "condition_label": "Reported problem",
      "availability_label": "Availability unconfirmed",
      "has_reported_problem": true,
      "condition_description": "Do not use until staff have reviewed the reported problem.",
      "search_text": "pool-zeiss-1022-818 ZEISS Plan-NEOFLUAR 40x/1.3 Oil 1022-818 (1080-398) 1022-818 (1080-398) Plan-NEOFLUAR 40x/1.3 Oil\tWD 0,21\nInner lenses with droplets! Thread M27/0.75 Oil immersion Objective Reported problem 40x Inner lenses with droplets!",
      "enquiry": "Hi AIC Turku team,\nCould you check whether this item is available and suitable for my experiment?\nItem: ZEISS Plan-NEOFLUAR 40x/1.3 Oil\nPool record: pool-zeiss-1022-818; product code: 1022-818 (1080-398)\nRecorded condition: Reported problem\nCondition note: Inner lenses with droplets!\nAvailability: Availability unconfirmed\nMicroscope: [please enter]\nExperiment and planned date: [please enter]\nPlease confirm compatibility and arrange any installation. Thank you."
    },
    {
      "id": "pool-zeiss-420852-9871",
      "family_id": "zeiss",
      "kind": "objective",
      "name": "LD LCI Plan-APOCHROMAT 25x/0.8 Imm Korr DIC (UV)-VIS-IR",
      "product_code": "420852-9871",
      "magnification": 25,
      "numerical_aperture_text": "0.8",
      "immersion": "universal",
      "working_distance_text": "0,57",
      "condition": "not_assessed",
      "condition_note": null,
      "availability": "unconfirmed",
      "location": null,
      "quantity": null,
      "inspection": null,
      "source_page": 1,
      "source_text": "420852-9871 LD LCI Plan-APOCHROMAT 25x/0.8 Imm\tWD 0,57\nKorr DIC (UV)-VIS-IR",
      "order": 16,
      "family_label": "ZEISS",
      "mount_label": "Thread M27/0.75",
      "source_heading": "ZEISS\tThread M27/0.75",
      "magnification_label": "25x",
      "kind_label": "Objective",
      "immersion_label": "Universal immersion",
      "condition_label": "Not assessed",
      "availability_label": "Availability unconfirmed",
      "has_reported_problem": false,
      "condition_description": "No problem noted in the source; this is not a serviceability check.",
      "search_text": "pool-zeiss-420852-9871 ZEISS LD LCI Plan-APOCHROMAT 25x/0.8 Imm Korr DIC (UV)-VIS-IR 420852-9871 420852-9871 LD LCI Plan-APOCHROMAT 25x/0.8 Imm\tWD 0,57\nKorr DIC (UV)-VIS-IR Thread M27/0.75 Universal immersion Objective Not assessed 25x ",
      "enquiry": "Hi AIC Turku team,\nCould you check whether this item is available and suitable for my experiment?\nItem: ZEISS LD LCI Plan-APOCHROMAT 25x/0.8 Imm Korr DIC (UV)-VIS-IR\nPool record: pool-zeiss-420852-9871; product code: 420852-9871\nRecorded condition: Not assessed\nCondition note: No problem noted in the source; this is not a serviceability check.\nAvailability: Availability unconfirmed\nMicroscope: [please enter]\nExperiment and planned date: [please enter]\nPlease confirm compatibility and arrange any installation. Thank you."
    },
    {
      "id": "pool-zeiss-420639-9000-700",
      "family_id": "zeiss",
      "kind": "calibration",
      "name": "APO Calibration LSM (SN 53811)",
      "product_code": "420639-9000-700",
      "magnification": null,
      "numerical_aperture_text": null,
      "immersion": "not_recorded",
      "working_distance_text": null,
      "condition": "not_assessed",
      "condition_note": null,
      "availability": "unconfirmed",
      "location": null,
      "quantity": null,
      "inspection": null,
      "source_page": 1,
      "source_text": "420639-9000-700 APO Calibration LSM (SN 53811)",
      "order": 17,
      "family_label": "ZEISS",
      "mount_label": "Thread M27/0.75",
      "source_heading": "ZEISS\tThread M27/0.75",
      "magnification_label": "Not recorded",
      "kind_label": "Calibration item",
      "immersion_label": "Not recorded",
      "condition_label": "Not assessed",
      "availability_label": "Availability unconfirmed",
      "has_reported_problem": false,
      "condition_description": "No problem noted in the source; this is not a serviceability check.",
      "search_text": "pool-zeiss-420639-9000-700 ZEISS APO Calibration LSM (SN 53811) 420639-9000-700 420639-9000-700 APO Calibration LSM (SN 53811) Thread M27/0.75 Not recorded Calibration item Not assessed Not recorded ",
      "enquiry": "Hi AIC Turku team,\nCould you check whether this item is available and suitable for my experiment?\nItem: ZEISS APO Calibration LSM (SN 53811)\nPool record: pool-zeiss-420639-9000-700; product code: 420639-9000-700\nRecorded condition: Not assessed\nCondition note: No problem noted in the source; this is not a serviceability check.\nAvailability: Availability unconfirmed\nMicroscope: [please enter]\nExperiment and planned date: [please enter]\nPlease confirm compatibility and arrange any installation. Thank you."
    },
    {
      "id": "pool-leica-506170",
      "family_id": "leica",
      "kind": "objective",
      "name": "HC Plan Apo 20x/0.70 PH2",
      "product_code": "506170",
      "magnification": 20,
      "numerical_aperture_text": "0.70",
      "immersion": "dry",
      "working_distance_text": null,
      "working_distance_verification": {
        "value_mm": 0.59,
        "unit": "mm",
        "source": "University of Bristol Confocal 9 technical specification",
        "url": "https://www.bristol.ac.uk/media-library/sites/wolfson-bioimaging/documents/confocal-9%20tech%20specs%20.pdf",
        "note": "The pool source leaves WD blank; the exact 506170 objective is independently documented with a 0.59 mm working distance."
      },
      "condition": "not_assessed",
      "condition_note": null,
      "availability": "unconfirmed",
      "location": null,
      "quantity": null,
      "inspection": null,
      "source_page": 2,
      "source_text": "506170 HC Plan Apo 20x/0.70 PH2\t\tWD ",
      "order": 18,
      "family_label": "Leica",
      "mount_label": "Thread M25",
      "source_heading": "Leica \tThread M25",
      "magnification_label": "20x",
      "kind_label": "Objective",
      "immersion_label": "Dry",
      "condition_label": "Not assessed",
      "availability_label": "Availability unconfirmed",
      "has_reported_problem": false,
      "condition_description": "No problem noted in the source; this is not a serviceability check.",
      "search_text": "pool-leica-506170 Leica HC Plan Apo 20x/0.70 PH2 506170 506170 HC Plan Apo 20x/0.70 PH2\t\tWD  Thread M25 Dry Objective Not assessed 20x ",
      "enquiry": "Hi AIC Turku team,\nCould you check whether this item is available and suitable for my experiment?\nItem: Leica HC Plan Apo 20x/0.70 PH2\nPool record: pool-leica-506170; product code: 506170\nRecorded condition: Not assessed\nCondition note: No problem noted in the source; this is not a serviceability check.\nAvailability: Availability unconfirmed\nMicroscope: [please enter]\nExperiment and planned date: [please enter]\nPlease confirm compatibility and arrange any installation. Thank you."
    },
    {
      "id": "pool-leica-506147",
      "family_id": "leica",
      "kind": "objective",
      "name": "L 20x/0.50 W U-V-I",
      "product_code": "506147",
      "magnification": 20,
      "numerical_aperture_text": "0.50",
      "immersion": "water_dipping",
      "working_distance_text": "3,5",
      "condition": "not_assessed",
      "condition_note": null,
      "availability": "unconfirmed",
      "location": null,
      "quantity": null,
      "inspection": null,
      "source_page": 2,
      "source_text": "506147\tL 20x/0.50 W U-V-I\t\t\tWD 3,5",
      "order": 19,
      "family_label": "Leica",
      "mount_label": "Thread M25",
      "source_heading": "Leica \tThread M25",
      "magnification_label": "20x",
      "kind_label": "Objective",
      "immersion_label": "Water dipping",
      "condition_label": "Not assessed",
      "availability_label": "Availability unconfirmed",
      "has_reported_problem": false,
      "condition_description": "No problem noted in the source; this is not a serviceability check.",
      "search_text": "pool-leica-506147 Leica L 20x/0.50 W U-V-I 506147 506147\tL 20x/0.50 W U-V-I\t\t\tWD 3,5 Thread M25 Water dipping Objective Not assessed 20x ",
      "enquiry": "Hi AIC Turku team,\nCould you check whether this item is available and suitable for my experiment?\nItem: Leica L 20x/0.50 W U-V-I\nPool record: pool-leica-506147; product code: 506147\nRecorded condition: Not assessed\nCondition note: No problem noted in the source; this is not a serviceability check.\nAvailability: Availability unconfirmed\nMicroscope: [please enter]\nExperiment and planned date: [please enter]\nPlease confirm compatibility and arrange any installation. Thank you."
    },
    {
      "id": "pool-leica-506155",
      "family_id": "leica",
      "kind": "objective",
      "name": "L 40x/0.80 W U-V-I",
      "product_code": "506155",
      "magnification": 40,
      "numerical_aperture_text": "0.80",
      "immersion": "water_dipping",
      "working_distance_text": "3,3",
      "condition": "not_assessed",
      "condition_note": null,
      "availability": "unconfirmed",
      "location": null,
      "quantity": null,
      "inspection": null,
      "source_page": 2,
      "source_text": "506155\tL 40x/0.80 W U-V-I\t\t\tWD 3,3",
      "order": 20,
      "family_label": "Leica",
      "mount_label": "Thread M25",
      "source_heading": "Leica \tThread M25",
      "magnification_label": "40x",
      "kind_label": "Objective",
      "immersion_label": "Water dipping",
      "condition_label": "Not assessed",
      "availability_label": "Availability unconfirmed",
      "has_reported_problem": false,
      "condition_description": "No problem noted in the source; this is not a serviceability check.",
      "search_text": "pool-leica-506155 Leica L 40x/0.80 W U-V-I 506155 506155\tL 40x/0.80 W U-V-I\t\t\tWD 3,3 Thread M25 Water dipping Objective Not assessed 40x ",
      "enquiry": "Hi AIC Turku team,\nCould you check whether this item is available and suitable for my experiment?\nItem: Leica L 40x/0.80 W U-V-I\nPool record: pool-leica-506155; product code: 506155\nRecorded condition: Not assessed\nCondition note: No problem noted in the source; this is not a serviceability check.\nAvailability: Availability unconfirmed\nMicroscope: [please enter]\nExperiment and planned date: [please enter]\nPlease confirm compatibility and arrange any installation. Thank you."
    },
    {
      "id": "pool-leica-506131",
      "family_id": "leica",
      "kind": "objective",
      "name": "PL APO 63x/1.20 W CORR",
      "product_code": "506131",
      "magnification": 63,
      "numerical_aperture_text": "1.20",
      "immersion": "water",
      "working_distance_text": "0,22",
      "condition": "not_assessed",
      "condition_note": null,
      "availability": "unconfirmed",
      "location": null,
      "quantity": null,
      "inspection": null,
      "source_page": 2,
      "source_text": "506131\tPL APO 63x/1.20 W CORR\t\tWD 0,22",
      "order": 21,
      "family_label": "Leica",
      "mount_label": "Thread M25",
      "source_heading": "Leica \tThread M25",
      "magnification_label": "63x",
      "kind_label": "Objective",
      "immersion_label": "Water immersion",
      "condition_label": "Not assessed",
      "availability_label": "Availability unconfirmed",
      "has_reported_problem": false,
      "condition_description": "No problem noted in the source; this is not a serviceability check.",
      "search_text": "pool-leica-506131 Leica PL APO 63x/1.20 W CORR 506131 506131\tPL APO 63x/1.20 W CORR\t\tWD 0,22 Thread M25 Water immersion Objective Not assessed 63x ",
      "enquiry": "Hi AIC Turku team,\nCould you check whether this item is available and suitable for my experiment?\nItem: Leica PL APO 63x/1.20 W CORR\nPool record: pool-leica-506131; product code: 506131\nRecorded condition: Not assessed\nCondition note: No problem noted in the source; this is not a serviceability check.\nAvailability: Availability unconfirmed\nMicroscope: [please enter]\nExperiment and planned date: [please enter]\nPlease confirm compatibility and arrange any installation. Thank you."
    },
    {
      "id": "pool-leica-506279",
      "family_id": "leica",
      "kind": "objective",
      "name": "HCX PL APO 63x/1.20 W CORR CS",
      "product_code": "506279",
      "magnification": 63,
      "numerical_aperture_text": "1.20",
      "immersion": "water",
      "working_distance_text": "0,22",
      "condition": "not_assessed",
      "condition_note": null,
      "availability": "unconfirmed",
      "location": null,
      "quantity": null,
      "inspection": null,
      "source_page": 2,
      "source_text": "506279\tHCX PL APO 63x/1.20 W CORR CS\tWD 0,22",
      "order": 22,
      "family_label": "Leica",
      "mount_label": "Thread M25",
      "source_heading": "Leica \tThread M25",
      "magnification_label": "63x",
      "kind_label": "Objective",
      "immersion_label": "Water immersion",
      "condition_label": "Not assessed",
      "availability_label": "Availability unconfirmed",
      "has_reported_problem": false,
      "condition_description": "No problem noted in the source; this is not a serviceability check.",
      "search_text": "pool-leica-506279 Leica HCX PL APO 63x/1.20 W CORR CS 506279 506279\tHCX PL APO 63x/1.20 W CORR CS\tWD 0,22 Thread M25 Water immersion Objective Not assessed 63x ",
      "enquiry": "Hi AIC Turku team,\nCould you check whether this item is available and suitable for my experiment?\nItem: Leica HCX PL APO 63x/1.20 W CORR CS\nPool record: pool-leica-506279; product code: 506279\nRecorded condition: Not assessed\nCondition note: No problem noted in the source; this is not a serviceability check.\nAvailability: Availability unconfirmed\nMicroscope: [please enter]\nExperiment and planned date: [please enter]\nPlease confirm compatibility and arrange any installation. Thank you."
    },
    {
      "id": "pool-leica-506006",
      "family_id": "leica",
      "kind": "objective",
      "name": "PL FLUOTAR 25x/0.75 OIL",
      "product_code": "506006",
      "magnification": 25,
      "numerical_aperture_text": "0.75",
      "immersion": "oil",
      "working_distance_text": "0,18",
      "condition": "not_assessed",
      "condition_note": null,
      "availability": "unconfirmed",
      "location": null,
      "quantity": null,
      "inspection": null,
      "source_page": 2,
      "source_text": "506006\tPL FLUOTAR 25x/0.75 OIL\t\tWD 0,18",
      "order": 23,
      "family_label": "Leica",
      "mount_label": "Thread M25",
      "source_heading": "Leica \tThread M25",
      "magnification_label": "25x",
      "kind_label": "Objective",
      "immersion_label": "Oil immersion",
      "condition_label": "Not assessed",
      "availability_label": "Availability unconfirmed",
      "has_reported_problem": false,
      "condition_description": "No problem noted in the source; this is not a serviceability check.",
      "search_text": "pool-leica-506006 Leica PL FLUOTAR 25x/0.75 OIL 506006 506006\tPL FLUOTAR 25x/0.75 OIL\t\tWD 0,18 Thread M25 Oil immersion Objective Not assessed 25x ",
      "enquiry": "Hi AIC Turku team,\nCould you check whether this item is available and suitable for my experiment?\nItem: Leica PL FLUOTAR 25x/0.75 OIL\nPool record: pool-leica-506006; product code: 506006\nRecorded condition: Not assessed\nCondition note: No problem noted in the source; this is not a serviceability check.\nAvailability: Availability unconfirmed\nMicroscope: [please enter]\nExperiment and planned date: [please enter]\nPlease confirm compatibility and arrange any installation. Thank you."
    },
    {
      "id": "pool-leica-506007",
      "family_id": "leica",
      "kind": "objective",
      "name": "PL FLUOTAR 40x/1.00-0.50 OIL",
      "product_code": "506007",
      "magnification": 40,
      "numerical_aperture_text": "1.00-0.50",
      "immersion": "oil",
      "working_distance_text": "0,08",
      "condition": "reported_issue",
      "condition_note": "iris diaphragm stuck",
      "availability": "unconfirmed",
      "location": null,
      "quantity": null,
      "inspection": null,
      "source_page": 2,
      "source_text": "506007\tPL FLUOTAR 40x/1.00-0.50 OIL\t\tWD 0,08\tiris diaphragm stuck",
      "order": 24,
      "family_label": "Leica",
      "mount_label": "Thread M25",
      "source_heading": "Leica \tThread M25",
      "magnification_label": "40x",
      "kind_label": "Objective",
      "immersion_label": "Oil immersion",
      "condition_label": "Reported problem",
      "availability_label": "Availability unconfirmed",
      "has_reported_problem": true,
      "condition_description": "Do not use until staff have reviewed the reported problem.",
      "search_text": "pool-leica-506007 Leica PL FLUOTAR 40x/1.00-0.50 OIL 506007 506007\tPL FLUOTAR 40x/1.00-0.50 OIL\t\tWD 0,08\tiris diaphragm stuck Thread M25 Oil immersion Objective Reported problem 40x iris diaphragm stuck",
      "enquiry": "Hi AIC Turku team,\nCould you check whether this item is available and suitable for my experiment?\nItem: Leica PL FLUOTAR 40x/1.00-0.50 OIL\nPool record: pool-leica-506007; product code: 506007\nRecorded condition: Reported problem\nCondition note: iris diaphragm stuck\nAvailability: Availability unconfirmed\nMicroscope: [please enter]\nExperiment and planned date: [please enter]\nPlease confirm compatibility and arrange any installation. Thank you."
    },
    {
      "id": "pool-leica-506082",
      "family_id": "leica",
      "kind": "objective",
      "name": "PL APO 63x/1.32 OIL PH3",
      "product_code": "506082",
      "magnification": 63,
      "numerical_aperture_text": "1.32",
      "immersion": "oil",
      "working_distance_text": "0,17",
      "working_distance_verification": {
        "value_mm": 0.07,
        "unit": "mm",
        "source": "University of Bristol Wide-field imaging system 1 technical specification",
        "url": "https://www.bristol.ac.uk/media-library/sites/wolfson-bioimaging/documents/widefield-1%20tech%20specs.pdf",
        "note": "The pool source records WD 0,17, but the exact 506082 objective is independently documented with WD 0.07 mm; 0.17 mm is the cover-glass specification."
      },
      "condition": "reported_issue",
      "condition_note": "problem with UV transmission",
      "availability": "unconfirmed",
      "location": null,
      "quantity": null,
      "inspection": null,
      "source_page": 2,
      "source_text": "506082\tPL APO 63x/1.32 OIL PH3\t\tWD 0,17\tproblem with UV transmission",
      "order": 25,
      "family_label": "Leica",
      "mount_label": "Thread M25",
      "source_heading": "Leica \tThread M25",
      "magnification_label": "63x",
      "kind_label": "Objective",
      "immersion_label": "Oil immersion",
      "condition_label": "Reported problem",
      "availability_label": "Availability unconfirmed",
      "has_reported_problem": true,
      "condition_description": "Do not use until staff have reviewed the reported problem.",
      "search_text": "pool-leica-506082 Leica PL APO 63x/1.32 OIL PH3 506082 506082\tPL APO 63x/1.32 OIL PH3\t\tWD 0,17\tproblem with UV transmission Thread M25 Oil immersion Objective Reported problem 63x problem with UV transmission",
      "enquiry": "Hi AIC Turku team,\nCould you check whether this item is available and suitable for my experiment?\nItem: Leica PL APO 63x/1.32 OIL PH3\nPool record: pool-leica-506082; product code: 506082\nRecorded condition: Reported problem\nCondition note: problem with UV transmission\nAvailability: Availability unconfirmed\nMicroscope: [please enter]\nExperiment and planned date: [please enter]\nPlease confirm compatibility and arrange any installation. Thank you."
    },
    {
      "id": "pool-leica-506188",
      "family_id": "leica",
      "kind": "objective",
      "name": "HCX PL APO 63x/1.40-0.60 OIL CS",
      "product_code": "506188",
      "magnification": 63,
      "numerical_aperture_text": "1.40-0.60",
      "immersion": "oil",
      "working_distance_text": "0,14",
      "condition": "not_assessed",
      "condition_note": null,
      "availability": "unconfirmed",
      "location": null,
      "quantity": null,
      "inspection": null,
      "source_page": 2,
      "source_text": "506188\tHCX PL APO 63x/1.40-0.60 OIL CS\tWD 0,14",
      "order": 26,
      "family_label": "Leica",
      "mount_label": "Thread M25",
      "source_heading": "Leica \tThread M25",
      "magnification_label": "63x",
      "kind_label": "Objective",
      "immersion_label": "Oil immersion",
      "condition_label": "Not assessed",
      "availability_label": "Availability unconfirmed",
      "has_reported_problem": false,
      "condition_description": "No problem noted in the source; this is not a serviceability check.",
      "search_text": "pool-leica-506188 Leica HCX PL APO 63x/1.40-0.60 OIL CS 506188 506188\tHCX PL APO 63x/1.40-0.60 OIL CS\tWD 0,14 Thread M25 Oil immersion Objective Not assessed 63x ",
      "enquiry": "Hi AIC Turku team,\nCould you check whether this item is available and suitable for my experiment?\nItem: Leica HCX PL APO 63x/1.40-0.60 OIL CS\nPool record: pool-leica-506188; product code: 506188\nRecorded condition: Not assessed\nCondition note: No problem noted in the source; this is not a serviceability check.\nAvailability: Availability unconfirmed\nMicroscope: [please enter]\nExperiment and planned date: [please enter]\nPlease confirm compatibility and arrange any installation. Thank you."
    },
    {
      "id": "pool-leica-506316",
      "family_id": "leica",
      "kind": "objective",
      "name": "PL APO 100x/1.40-0.70 OIL",
      "product_code": "506316",
      "magnification": 100,
      "numerical_aperture_text": "1.40-0.70",
      "immersion": "oil",
      "working_distance_text": "0,09",
      "condition": "reported_issue",
      "condition_note": "iris diaphragm stuck",
      "availability": "unconfirmed",
      "location": null,
      "quantity": null,
      "inspection": null,
      "source_page": 2,
      "source_text": "506316\tPL APO 100x/1.40-0.70 OIL \t\tWD 0,09\tiris diaphragm stuck",
      "order": 27,
      "family_label": "Leica",
      "mount_label": "Thread M25",
      "source_heading": "Leica \tThread M25",
      "magnification_label": "100x",
      "kind_label": "Objective",
      "immersion_label": "Oil immersion",
      "condition_label": "Reported problem",
      "availability_label": "Availability unconfirmed",
      "has_reported_problem": true,
      "condition_description": "Do not use until staff have reviewed the reported problem.",
      "search_text": "pool-leica-506316 Leica PL APO 100x/1.40-0.70 OIL 506316 506316\tPL APO 100x/1.40-0.70 OIL \t\tWD 0,09\tiris diaphragm stuck Thread M25 Oil immersion Objective Reported problem 100x iris diaphragm stuck",
      "enquiry": "Hi AIC Turku team,\nCould you check whether this item is available and suitable for my experiment?\nItem: Leica PL APO 100x/1.40-0.70 OIL\nPool record: pool-leica-506316; product code: 506316\nRecorded condition: Reported problem\nCondition note: iris diaphragm stuck\nAvailability: Availability unconfirmed\nMicroscope: [please enter]\nExperiment and planned date: [please enter]\nPlease confirm compatibility and arrange any installation. Thank you."
    },
    {
      "id": "pool-leica-506002",
      "family_id": "leica",
      "kind": "objective",
      "name": "PL FLUOTAR 16x/0.50 IMM",
      "product_code": "506002",
      "magnification": 16,
      "numerical_aperture_text": "0.50",
      "immersion": "universal",
      "working_distance_text": "0,15",
      "condition": "not_assessed",
      "condition_note": null,
      "availability": "unconfirmed",
      "location": null,
      "quantity": null,
      "inspection": null,
      "source_page": 2,
      "source_text": "506002\tPL FLUOTAR 16x/0.50 IMM\t\tWD 0,15",
      "order": 28,
      "family_label": "Leica",
      "mount_label": "Thread M25",
      "source_heading": "Leica \tThread M25",
      "magnification_label": "16x",
      "kind_label": "Objective",
      "immersion_label": "Universal immersion",
      "condition_label": "Not assessed",
      "availability_label": "Availability unconfirmed",
      "has_reported_problem": false,
      "condition_description": "No problem noted in the source; this is not a serviceability check.",
      "search_text": "pool-leica-506002 Leica PL FLUOTAR 16x/0.50 IMM 506002 506002\tPL FLUOTAR 16x/0.50 IMM\t\tWD 0,15 Thread M25 Universal immersion Objective Not assessed 16x ",
      "enquiry": "Hi AIC Turku team,\nCould you check whether this item is available and suitable for my experiment?\nItem: Leica PL FLUOTAR 16x/0.50 IMM\nPool record: pool-leica-506002; product code: 506002\nRecorded condition: Not assessed\nCondition note: No problem noted in the source; this is not a serviceability check.\nAvailability: Availability unconfirmed\nMicroscope: [please enter]\nExperiment and planned date: [please enter]\nPlease confirm compatibility and arrange any installation. Thank you."
    },
    {
      "id": "pool-olympus-a10x-0-25",
      "family_id": "olympus",
      "kind": "objective",
      "name": "A10x/0.25",
      "product_code": null,
      "magnification": 10,
      "numerical_aperture_text": "0.25",
      "immersion": "not_recorded",
      "working_distance_text": null,
      "condition": "not_assessed",
      "condition_note": null,
      "availability": "unconfirmed",
      "location": null,
      "quantity": null,
      "inspection": null,
      "source_page": 2,
      "source_text": "A10x/0.25",
      "order": 29,
      "family_label": "OLYMPUS, Japan",
      "mount_label": "thread 20 (as written)",
      "source_heading": "OLYMPUS, Japan\n-tubus length 160, thread 20",
      "magnification_label": "10x",
      "kind_label": "Objective",
      "immersion_label": "Not recorded",
      "condition_label": "Not assessed",
      "availability_label": "Availability unconfirmed",
      "has_reported_problem": false,
      "condition_description": "No problem noted in the source; this is not a serviceability check.",
      "search_text": "pool-olympus-a10x-0-25 OLYMPUS, Japan A10x/0.25  A10x/0.25 thread 20 (as written) Not recorded Objective Not assessed 10x ",
      "enquiry": "Hi AIC Turku team,\nCould you check whether this item is available and suitable for my experiment?\nItem: OLYMPUS, Japan A10x/0.25\nPool record: pool-olympus-a10x-0-25; product code: not recorded\nRecorded condition: Not assessed\nCondition note: No problem noted in the source; this is not a serviceability check.\nAvailability: Availability unconfirmed\nMicroscope: [please enter]\nExperiment and planned date: [please enter]\nPlease confirm compatibility and arrange any installation. Thank you."
    },
    {
      "id": "pool-olympus-lwd-cdplan-20x-0-40-pl",
      "family_id": "olympus",
      "kind": "objective",
      "name": "LWD CDPlan 20x/0.40 PL",
      "product_code": null,
      "magnification": 20,
      "numerical_aperture_text": "0.40",
      "immersion": "not_recorded",
      "working_distance_text": null,
      "condition": "reported_issue",
      "condition_note": "correction collar stuck",
      "availability": "unconfirmed",
      "location": null,
      "quantity": null,
      "inspection": null,
      "source_page": 2,
      "source_text": "LWD CDPlan 20x/0.40 PL\tphase, correction collar stuck",
      "order": 30,
      "family_label": "OLYMPUS, Japan",
      "mount_label": "thread 20 (as written)",
      "source_heading": "OLYMPUS, Japan\n-tubus length 160, thread 20",
      "magnification_label": "20x",
      "kind_label": "Objective",
      "immersion_label": "Not recorded",
      "condition_label": "Reported problem",
      "availability_label": "Availability unconfirmed",
      "has_reported_problem": true,
      "condition_description": "Do not use until staff have reviewed the reported problem.",
      "search_text": "pool-olympus-lwd-cdplan-20x-0-40-pl OLYMPUS, Japan LWD CDPlan 20x/0.40 PL  LWD CDPlan 20x/0.40 PL\tphase, correction collar stuck thread 20 (as written) Not recorded Objective Reported problem 20x correction collar stuck",
      "enquiry": "Hi AIC Turku team,\nCould you check whether this item is available and suitable for my experiment?\nItem: OLYMPUS, Japan LWD CDPlan 20x/0.40 PL\nPool record: pool-olympus-lwd-cdplan-20x-0-40-pl; product code: not recorded\nRecorded condition: Reported problem\nCondition note: correction collar stuck\nAvailability: Availability unconfirmed\nMicroscope: [please enter]\nExperiment and planned date: [please enter]\nPlease confirm compatibility and arrange any installation. Thank you."
    },
    {
      "id": "pool-olympus-lwd-cdplan-40x-0-55-pl",
      "family_id": "olympus",
      "kind": "objective",
      "name": "LWD CDPlan 40x/0.55 PL",
      "product_code": null,
      "magnification": 40,
      "numerical_aperture_text": "0.55",
      "immersion": "not_recorded",
      "working_distance_text": null,
      "condition": "reported_issue",
      "condition_note": "correction collar stuck",
      "availability": "unconfirmed",
      "location": null,
      "quantity": null,
      "inspection": null,
      "source_page": 2,
      "source_text": "LWD CDPlan 40x/0.55 PL \tphase, correction collar stuck",
      "order": 31,
      "family_label": "OLYMPUS, Japan",
      "mount_label": "thread 20 (as written)",
      "source_heading": "OLYMPUS, Japan\n-tubus length 160, thread 20",
      "magnification_label": "40x",
      "kind_label": "Objective",
      "immersion_label": "Not recorded",
      "condition_label": "Reported problem",
      "availability_label": "Availability unconfirmed",
      "has_reported_problem": true,
      "condition_description": "Do not use until staff have reviewed the reported problem.",
      "search_text": "pool-olympus-lwd-cdplan-40x-0-55-pl OLYMPUS, Japan LWD CDPlan 40x/0.55 PL  LWD CDPlan 40x/0.55 PL \tphase, correction collar stuck thread 20 (as written) Not recorded Objective Reported problem 40x correction collar stuck",
      "enquiry": "Hi AIC Turku team,\nCould you check whether this item is available and suitable for my experiment?\nItem: OLYMPUS, Japan LWD CDPlan 40x/0.55 PL\nPool record: pool-olympus-lwd-cdplan-40x-0-55-pl; product code: not recorded\nRecorded condition: Reported problem\nCondition note: correction collar stuck\nAvailability: Availability unconfirmed\nMicroscope: [please enter]\nExperiment and planned date: [please enter]\nPlease confirm compatibility and arrange any installation. Thank you."
    },
    {
      "id": "pool-incucyte-4628",
      "family_id": "incucyte",
      "kind": "objective",
      "name": "10x/0.30",
      "product_code": "4628",
      "magnification": 10,
      "numerical_aperture_text": "0.30",
      "immersion": "not_recorded",
      "working_distance_text": null,
      "condition": "reported_unusable",
      "condition_note": "LENSES TOTALLY RUINED!",
      "availability": "unconfirmed",
      "location": null,
      "quantity": null,
      "inspection": null,
      "source_page": 2,
      "source_text": "4628\t10x/0.30\tLENSES TOTALLY RUINED!",
      "order": 32,
      "family_label": "IncuCyte by ESSEN BIOSCIENCE",
      "mount_label": "thread -23 (as written)",
      "source_heading": "IncuCyte by ESSEN BIOSCIENCE\n-thread -23",
      "magnification_label": "10x",
      "kind_label": "Objective",
      "immersion_label": "Not recorded",
      "condition_label": "Reported unusable",
      "availability_label": "Availability unconfirmed",
      "has_reported_problem": true,
      "condition_description": "Recorded as unusable. Not offered for imaging.",
      "search_text": "pool-incucyte-4628 IncuCyte by ESSEN BIOSCIENCE 10x/0.30 4628 4628\t10x/0.30\tLENSES TOTALLY RUINED! thread -23 (as written) Not recorded Objective Reported unusable 10x LENSES TOTALLY RUINED!",
      "enquiry": "Hi AIC Turku team,\nCould you advise on the status of this reported-unusable item?\nItem: IncuCyte by ESSEN BIOSCIENCE 10x/0.30\nPool record: pool-incucyte-4628; product code: 4628\nRecorded condition: Reported unusable\nCondition note: LENSES TOTALLY RUINED!\nAvailability: Availability unconfirmed\nMicroscope: [please enter]\nExperiment and planned date: [please enter]\nPlease confirm compatibility and arrange any installation. Thank you."
    },
    {
      "id": "pool-incucyte-4629",
      "family_id": "incucyte",
      "kind": "objective",
      "name": "20x/0.45",
      "product_code": "4629",
      "magnification": 20,
      "numerical_aperture_text": "0.45",
      "immersion": "not_recorded",
      "working_distance_text": null,
      "condition": "reported_issue",
      "condition_note": "LENSES IN POOR CONDITION!",
      "availability": "unconfirmed",
      "location": null,
      "quantity": null,
      "inspection": null,
      "source_page": 2,
      "source_text": "4629\t20x/0.45\tLENSES IN POOR CONDITION!",
      "order": 33,
      "family_label": "IncuCyte by ESSEN BIOSCIENCE",
      "mount_label": "thread -23 (as written)",
      "source_heading": "IncuCyte by ESSEN BIOSCIENCE\n-thread -23",
      "magnification_label": "20x",
      "kind_label": "Objective",
      "immersion_label": "Not recorded",
      "condition_label": "Reported problem",
      "availability_label": "Availability unconfirmed",
      "has_reported_problem": true,
      "condition_description": "Do not use until staff have reviewed the reported problem.",
      "search_text": "pool-incucyte-4629 IncuCyte by ESSEN BIOSCIENCE 20x/0.45 4629 4629\t20x/0.45\tLENSES IN POOR CONDITION! thread -23 (as written) Not recorded Objective Reported problem 20x LENSES IN POOR CONDITION!",
      "enquiry": "Hi AIC Turku team,\nCould you check whether this item is available and suitable for my experiment?\nItem: IncuCyte by ESSEN BIOSCIENCE 20x/0.45\nPool record: pool-incucyte-4629; product code: 4629\nRecorded condition: Reported problem\nCondition note: LENSES IN POOR CONDITION!\nAvailability: Availability unconfirmed\nMicroscope: [please enter]\nExperiment and planned date: [please enter]\nPlease confirm compatibility and arrange any installation. Thank you."
    },
    {
      "id": "pool-nikon-mrh-00041",
      "family_id": "nikon",
      "kind": "objective",
      "name": "Plan Fluo 4x/0.13 OFN 25",
      "product_code": "MRH 00041",
      "magnification": 4,
      "numerical_aperture_text": "0.13",
      "immersion": "not_recorded",
      "working_distance_text": "17,2",
      "condition": "not_assessed",
      "condition_note": null,
      "availability": "unconfirmed",
      "location": null,
      "quantity": null,
      "inspection": null,
      "source_page": 2,
      "source_text": "MRH 00041 Plan Fluo 4x/0.13 OFN 25 WD 17,2",
      "order": 34,
      "family_label": "Nikon, Japan",
      "mount_label": "Not recorded",
      "source_heading": "Nikon, Japan",
      "magnification_label": "4x",
      "kind_label": "Objective",
      "immersion_label": "Not recorded",
      "condition_label": "Not assessed",
      "availability_label": "Availability unconfirmed",
      "has_reported_problem": false,
      "condition_description": "No problem noted in the source; this is not a serviceability check.",
      "search_text": "pool-nikon-mrh-00041 Nikon, Japan Plan Fluo 4x/0.13 OFN 25 MRH 00041 MRH 00041 Plan Fluo 4x/0.13 OFN 25 WD 17,2 Not recorded Not recorded Objective Not assessed 4x ",
      "enquiry": "Hi AIC Turku team,\nCould you check whether this item is available and suitable for my experiment?\nItem: Nikon, Japan Plan Fluo 4x/0.13 OFN 25\nPool record: pool-nikon-mrh-00041; product code: MRH 00041\nRecorded condition: Not assessed\nCondition note: No problem noted in the source; this is not a serviceability check.\nAvailability: Availability unconfirmed\nMicroscope: [please enter]\nExperiment and planned date: [please enter]\nPlease confirm compatibility and arrange any installation. Thank you."
    }
  ],
  "total": 35,
  "objective_count": 34,
  "problem_count": 8
}