Skip to content

Lambert FLIM

Work in progress

This dashboard is a work in progress. Please independently verify critical information, as not all features are working yet.

Lambert FLIM
Manufacturer
Lambert Instruments
Model
LIFA (frequency domain FLIM)
Stand
Inverted
Eyepieces
Trinocular
Location
BioCity, 5th floor, room 5149
Purchased
—
Funding
—
Modalities
Widefield Fluorescence Fluorescence Lifetime Imaging
Modules
FLIM Module


Software Environment

  • Unknown
    Acquisition
    Role: Acquisition

Hardware Configuration

💡 Light Sources

  • 406 nm LED Unknown Multi-LED excitation
    Unknown
    Type: LED
    Wavelength: 406 nm
    Notes: Excitation line

  • 469 nm LED Unknown Multi-LED excitation
    Unknown
    Type: LED
    Wavelength: 469 nm
    Notes: Excitation line

  • 533 nm LED Unknown Multi-LED excitation
    Unknown
    Type: LED
    Wavelength: 533 nm
    Notes: Excitation line

📷 Detectors

  • Lambert Instruments LIFA Camera
    Charge-Coupled Device
    Type: Charge-Coupled Device
    Notes: Assumed LIFA integrated frequency-domain FLIM camera.

🔬 Objectives

  • LD-Plan NEOFLUAR 20x/0.4 Ph2 Korr 20x/0.4 AIR
    Zeiss
    Model: LD-Plan NEOFLUAR 20x/0.4 Ph2 Korr
    Magnification / NA: 20x/0.4
    Immersion: Air
    Correction: Plan Fluorite
    Product code: 421351-9970
    AFC compatible: No
    Installed: Yes
    Specialties: phase
    Notes: Korr (correction collar)

  • Plan NEOFLUAR 40x/0.6 Ph2 Korr 40x/0.6 AIR
    Zeiss
    Model: Plan NEOFLUAR 40x/0.6 Ph2 Korr
    Magnification / NA: 40x/0.6
    Immersion: Air
    Correction: Plan Fluorite
    Product code: 421361-9970
    AFC compatible: No
    Installed: Yes
    Specialties: phase
    Notes: Korr (correction collar)

  • Plan APOCHROMAT 63x/1.4 Oil 63x/1.4 OIL
    Zeiss
    Model: Plan APOCHROMAT 63x/1.4 Oil
    Magnification / NA: 63x/1.4
    Immersion: Oil
    Correction: Plan Apochromat
    Product code: 420780-9900
    AFC compatible: No
    Installed: Yes


QC Metrics: Latest Measurements

🔦 Laser Performance

No laser performance metrics recorded recently.

🔬 Optical Resolution (PSF & Alignment)

No recent PSF or chromatic shift metrics available for any objectives.

Objectives without recent data
  • LD-Plan NEOFLUAR 20x/0.4 Ph2 Korr 20x/0.4 AIR (20x_air_ph2)

  • Plan NEOFLUAR 40x/0.6 Ph2 Korr 40x/0.6 AIR (40x_air_ph2)

  • Plan APOCHROMAT 63x/1.4 Oil 63x/1.4 OIL (63x_oil)

Metadata Completeness

  • Missing conditional fields (currently applicable):

  • software[].version — Software version

  • hardware.detectors[].pixel_pitch_um — Detector pixel pitch (um)

  • Legacy aliases in use (fallback accepted):

  • modules[].name → modules[].type

  • hardware.detectors[].pixel_size_um → hardware.detectors[].pixel_pitch_um

  • hardware.detectors[].min_nm → hardware.detectors[].collection_min_nm

  • hardware.detectors[].max_nm → hardware.detectors[].collection_max_nm

  • hardware.detectors[].channel_center_nm → hardware.detectors[].collection_center_nm

  • hardware.detectors[].bandwidth_nm → hardware.detectors[].collection_width_nm