Leica TCS SP5 Multiphoton
About this microscope
This microscope has been retired from service. The hardware and capabilities below are kept as a record of its final recorded configuration, so earlier work can still be described accurately.
Retired from service
This microscope is no longer available for booking. The Virtual Microscope covers microscopes currently in service, so it does not include this record.
Software
- Leica LAS AF
Acquisition
Role: Acquisition
Version: Not documented
Hardware
Light sources
-
Pulsed Near-IR Laser Coherent Chameleon Ultra II
Coherent
Type: Pulsed Near-IR Laser
Role: Excitation
Optical route: Multiphoton
Notes: tunable 690-1040 nm -
tunable Pulsed Near-IR Laser Coherent Compact OPO
Coherent
Type: Pulsed Near-IR Laser
Role: Excitation
Optical route: Multiphoton
Wavelength:tunable
Notes: extends tunable range to 1600 nm -
Pulsed Near-IR Laser Coherent Chameleon Vision II
Coherent
Type: Pulsed Near-IR Laser
Role: Excitation
Optical route: Multiphoton
Notes: tunable 690-1040 nm
Scanner
- Resonant Scanner
Type: Resonant Scanner
Detectors
- Photomultiplier Tubes (non-descanned)
Photomultiplier Tube
Type: Photomultiplier Tube
Objectives
View this microscope's objectives in the catalogue
-
HCX APO L 20x/1 WATER
Leica
Model: HCX APO L
Magnification / NA:20x/1
Immersion: Water
Correction: Apochromat
Working distance:1.95 mm
AFC compatible: No
Installed: Yes -
HCX IR APO L 25x/0.95 WATER
Leica
Model: HCX IR APO L
Magnification / NA:25x/0.95
Immersion: Water
Correction: Apochromat
Working distance:2.50 mm
AFC compatible: No
Installed: Yes
Latest QC measurements
Laser performance
No recent laser-performance measurements are recorded.
Optical resolution (PSF and alignment)
No recent PSF or chromatic-shift measurements are recorded for these objectives.
Objectives without recent measurements
-
HCX APO L 20x/1 WATER (
20x_water) -
HCX IR APO L 25x/0.95 WATER (
25x_water)
Information still to confirm
Some details in the facility record are incomplete. If any of these matter for your experiment, please check them with AIC Turku staff.
-
Not yet recorded:
-
Location (
instrument.location) -
Capability axes (
capabilities) -
Optical path element ID (
hardware.optical_path_elements[].id) -
Optical path element type (
hardware.optical_path_elements[].element_type) -
Light path route type (
light_paths[].route_type) -
Details needed for this configuration:
-
Software version (
software[].version) -
Scanner line rate (Hz) (
hardware.scanner.line_rate_hz) -
Detector ID (
hardware.detectors[].id) -
Detector manufacturer (
hardware.detectors[].manufacturer)