Skip to content
← Advanced Imaging Core Facility at Turku Bioscience Centre

Leica DM IRBE

About this microscope

Here you’ll find the hardware and capabilities currently recorded for this microscope. If you are planning an experiment, AIC Turku staff can help with access, training, and configuration choices.

Current status: 🟢 Online

Operational

QC and maintenance history Open Virtual Microscope

Leica DM IRBE microscope
Manufacturer
Leica Microsystems
Model
Leica DM IRBE
Stand
Inverted
Eyepieces
Trinocular
Location
BioCity, 2nd floor, room 2076
Purchased
—
Funding
—
Capabilities
These are the capabilities recorded for this microscope. Open the optical-route details below to see how the hardware is connected.
Widefield fluorescenceTransmitted brightfieldPhase contrastDarkfield
Methods and the light path that records them
Each method below is explicitly associated in the instrument record with the physical light path that implements it. An imaging mode or contrast method that appears above but not here has no recorded method-to-path mapping yet.
  • Widefield fluorescence: Widefield fluorescence
  • Transmitted light: Transmitted brightfield, Phase contrast, Darkfield


Software

No acquisition/control software — manual or standalone system.


Hardware

Light sources

  • Halogen Lamp Leica 12V 100W halogen bulb
    Leica
    Type: Halogen Lamp
    Role: Transmitted Illumination
    Power: 100 W
    Notes: Transmitted light source for BF, DF, and PH. Broadband illumination.

  • Arc Lamp Leica 50W HBO short arc bulb
    Leica
    Type: Arc Lamp
    Power: 50 W
    Notes: Fluorescence excitation source. Broadband illumination.

Detectors

  • Unknown Unknown Camera
    Charge-Coupled Device
    Type: Charge-Coupled Device
    Notes: Standalone camera system attached to port (no computer required); image storage via USB memory device.

Objectives

View this microscope's objectives in the catalogue

  • PL FLUOTAR 10x/0.30 PH1 AIR
    Leica
    Model: PL FLUOTAR 10x/0.30 PH1
    Magnification / NA: 10x/0.3
    Immersion: Air
    Correction: Plan Fluorite
    Working distance: 3.8 mm
    Product code: 506010
    AFC compatible: No
    Installed: Yes
    Specialties: phase
    Notes: Working distance verified against an exact 506010 legacy objective listing.

  • PL FLUOTAR 20x/0.50 PH2 AIR
    Leica
    Model: PL FLUOTAR 20x/0.50 PH2
    Magnification / NA: 20x/0.5
    Immersion: Air
    Correction: Plan Fluorite
    Product code: 506013
    AFC compatible: No
    Installed: Yes
    Specialties: phase

  • PL FLUOTAR 40x/0.70 PH2 AIR
    Leica
    Model: PL FLUOTAR 40x/0.70 PH2
    Magnification / NA: 40x/0.7
    Immersion: Air
    Correction: Plan Fluorite
    Product code: 506014
    AFC compatible: No
    Installed: Yes
    Specialties: phase

  • PL FLUOTAR 63x/0.70 CORR PH2 AIR
    Leica
    Model: PL FLUOTAR 63x/0.70 CORR PH2
    Magnification / NA: 63x/0.7
    Immersion: Air
    Correction: Plan Fluorite
    Working distance: 2.6-1.8 mm
    Product code: 506062
    AFC compatible: No
    Installed: Yes
    Specialties: phase, correction_collar
    Notes: Working-distance range cross-checked against an exact 506062 legacy objective listing.

Magnification changers

  • 1.6x Auxiliary Lens
    Leica
    Manufacturer: Leica
    Model: 1.6x Auxiliary Lens
    Magnification: 1.6x
    Notes: Optional 1.6x auxiliary lens in microscope body.

Optical-path elements

  • Fluorescence Turret
    Cube
    Element type: Turret
    Pos 1: Filter Cube A (DAPI/Hoechst) — Excitation: 360/40 nm. Dichroic Cutoff: 400 nm.
    Pos 2: Filter Cube EGFP — emission 525/50 nm — Excitation: 470/40 nm. Dichroic Cutoff: 495 nm.
    Pos 3: Filter Cube CY3 (TRITC/RFP) — emission 605/70 nm — Excitation: 545.5/25 nm. Dichroic Cutoff: 565 nm.

Latest QC measurements

Laser performance

No recent laser-performance measurements are recorded.

Optical resolution (PSF and alignment)

No recent PSF or chromatic-shift measurements are recorded for these objectives.

Objectives without recent measurements
  • PL FLUOTAR 10x/0.30 PH1 AIR (10x_air)

  • PL FLUOTAR 20x/0.50 PH2 AIR (20x_air)

  • PL FLUOTAR 40x/0.70 PH2 AIR (40x_air)

  • PL FLUOTAR 63x/0.70 CORR PH2 AIR (63x_air)

Information still to confirm

Some details in the facility record are incomplete. If any of these matter for your experiment, please check them with AIC Turku staff.

  • Details needed for this configuration:

  • Detector pixel pitch (um) (hardware.detectors[].pixel_pitch_um)