Nikon Eclipse Ti2-E
Work in progress
This dashboard is a work in progress. Please independently verify critical information, as not all features are working yet.
Current Status: ๐ข Online
Operational
๐ View QC & Maintenance History ๐ฌ Open Virtual Microscope
Software Environment
- Nikon NIS-Elements AR (v5.11)
Acquisition
Role: Acquisition
Version:5.11
Hardware Configuration
๐ก๏ธ Environmental Control
- Environmental Control
controlled temperature, controlled CO2, controlled humidity
Temperature control: Yes
CO2 control: Yes
Humidity control: Yes
Notes: Enclosed incubation chamber (Okolab) with temperature control (Okolab H201-T)
๐ก Light Sources
-
395 nm LED Lumencor Spectra X LED system
Lumencor
Type: LED
Wavelength:395 nm -
440 nm LED Lumencor Spectra X LED system
Lumencor
Type: LED
Wavelength:440 nm -
475 nm LED Lumencor Spectra X LED system
Lumencor
Type: LED
Wavelength:475 nm -
550 nm LED Lumencor Spectra X LED system
Lumencor
Type: LED
Wavelength:550 nm
Notes: 550 nm module available by request -
575 nm LED Lumencor Spectra X LED system
Lumencor
Type: LED
Wavelength:575 nm -
640 nm LED Lumencor Spectra X LED system
Lumencor
Type: LED
Wavelength:640 nm -
730 nm LED Lumencor Spectra X LED system
Lumencor
Type: LED
Wavelength:730 nm -
LED Nikon Ti2 Transmitted Illuminator
Nikon
Type: LED
Role: Transmitted Illumination
Notes: Broad spectrum transmitted source for BF/DIC.
๐ท Detectors
-
Hamamatsu Orca Flash4.0 V3
Scientific CMOS
Type: Scientific CMOS
Pixel pitch:6.5 ยตm
Sensor format:2048 x 2044
Notes: sCMOS -
Nikon DS-Fi3
Standard CMOS
Type: Standard CMOS
Pixel pitch:2.4 ยตm
Sensor format:2880 x 2048
Notes: Color CMOS
๐ฌ Objectives
-
Plan UW 2x/0.06 2x/0.06 AIR
Nikon
Model: Plan UW 2x/0.06
Magnification / NA:2x/0.06
Immersion: Air
Correction: Plan Achromat
Working distance:7.5 mm
Product code:MRL00022
AFC compatible: No
Installed: Yes
Specialties: polarization
Notes: Mode suitability: BF recommended; FLUO (VIS) possible; polarization possible. -
Plan Fluor 4x/0.13 4x/0.13 AIR
Nikon
Model: Plan Fluor 4x/0.13
Magnification / NA:4x/0.13
Immersion: Air
Correction: Plan Fluorite
Working distance:17.2 mm
Product code:MRH00041
AFC compatible: No
Installed: Yes
Specialties: polarization
Notes: Mode suitability: BF recommended; FLUO (VIS) recommended; FLUO (UV) recommended; polarization possible. -
Plan Apo ฮปD 4x/0.20 4x/0.2 AIR
Nikon
Model: Plan Apo ฮปD 4x/0.20
Magnification / NA:4x/0.2
Immersion: Air
Correction: Plan Apochromat
Working distance:20.0 mm
Product code:MRD70040
AFC compatible: No
Installed: Yes
Notes: Optical family: Lambda D. Mode suitability: BF recommended; FLUO (VIS) recommended; FLUO (NIR) recommended. -
Plan Fluor 10x/0.30 OFN 25 Ph1 DL 10x/0.3 AIR
Nikon
Model: Plan Fluor 10x/0.30 OFN 25 Ph1 DL
Magnification / NA:10x/0.3
Immersion: Air
Correction: Plan Fluorite
Working distance:15.2 mm
Product code:MRH20101
AFC compatible: Yes
Installed: Yes
Specialties: phase
Notes: OFN 25. Mode suitability: BF suitable; FLUO (VIS) suitable; FLUO (UV) suitable. -
S Plan Fluor ELWD ADM 20x/0.45 DIC N1 20x/0.45 AIR
Nikon
Model: S Plan Fluor ELWD ADM 20x/0.45 DIC N1
Magnification / NA:20x/0.45
Immersion: Air
Correction: Plan Fluorite
Working distance:8.2 - 6.9 mm
Product code:MRH08230
AFC compatible: Yes
Installed: Yes
Specialties: long_working_distance, dic, polarization
Notes: Mode suitability: BF recommended; FLUO (VIS) recommended; FLUO (UV) recommended; polarization suitable. -
Plan Apo ฮป 20x/0.75 OFN25 DIC N2 20x/0.75 AIR
Nikon
Model: Plan Apo ฮป 20x/0.75 OFN25 DIC N2
Magnification / NA:20x/0.75
Immersion: Air
Correction: Plan Apochromat
Working distance:1.0 mm
Product code:MRD00205
AFC compatible: Yes
Installed: Yes
Specialties: dic, polarization
Notes: OFN 25. Optical family: Lambda. Mode suitability: BF recommended; FLUO (VIS) recommended; FLUO (UV) recommended; polarization possible. -
S Plan Fluor ELWD 40x/0.60 OFN22 Ph2 40x/0.6 AIR
Nikon
Model: S Plan Fluor ELWD 40x/0.60 OFN22 Ph2
Magnification / NA:40x/0.6
Immersion: Air
Correction: Plan Fluorite
Working distance:3.6 - 2.8 mm
Product code:MRH48430
AFC compatible: Yes
Installed: Yes
Specialties: long_working_distance, phase
Notes: OFN 22. Mode suitability: BF suitable; FLUO (VIS) suitable; FLUO (UV) suitable. -
Plan Apo ฮป 60x/1.40 Oil OFN25 DIC N2 60x/1.4 OIL
Nikon
Model: Plan Apo ฮป 60x/1.40 Oil OFN25 DIC N2
Magnification / NA:60x/1.4
Immersion: Oil
Correction: Plan Apochromat
Working distance:0.13 mm
Product code:MRD01605
AFC compatible: Yes
Installed: Yes
Specialties: dic, polarization
Notes: OFN 25. Optical family: Lambda. Mode suitability: BF recommended; FLUO (VIS) recommended; FLUO (NIR) recommended; polarization suitable. -
Apo TIRF 100x/1.49 Oil 100x/1.49 OIL
Nikon
Model: Apo TIRF 100x/1.49 Oil
Magnification / NA:100x/1.49
Immersion: Oil
Correction: Apochromat
Working distance:0.16 - 0.10 mm
Product code:MRD01991
AFC compatible: Yes
Installed: Yes
Specialties: tirf, phase, dic, polarization
Notes: Mode suitability: BF recommended; FLUO (VIS) recommended; FLUO (UV) possible; polarization suitable.
โ๏ธ Advanced Hardware
- Infrared Reflection Autofocus
Installed: Yes
Type: Infrared Reflection Autofocus
๐๏ธ Optical Path Elements
-
Filter Turret
Dichroic
Element type: Turret
Pos 1: Chroma 89403bs (89403bs) โ Dichroic for CFP/YFP/mCherry/Cy7
Pos 2: Chroma 84000v2 (84000v2) โ Quad-band for DAPI/FITC/TRITC/Cy5
Pos 3: Chroma 96377 (96377) โ emission 809/81 nm โ Cy7 emission filter housed in turret -
Emission Wheel
Emission
Element type: Filter Wheel
Pos 1: DAPI Emission โ emission 435/26 nm
Pos 2: CFP Emission โ emission 475/20 nm
Pos 3: GFP Emission โ emission 515/30 nm
Pos 4: YFP Emission โ emission 540/21 nm
Pos 5: TRITC Emission โ emission 595/40 nm
Pos 6: mCherry Emission โ emission 632/60 nm
Pos 7: Cy5 Emission โ emission 705/71 nm -
Lamp Filter Cubes
Cube
Element type: Turret
Pos 1: Standard Cubes โ Standard DAPI, CFP, GFP, YFP, and TexasRed cubes -
DIC Fixed Analyzer
Analyzer
Element type: Slider
Pos 1: Analyzer โ For DIC imaging
QC Metrics: Latest Measurements
๐ฆ Laser Performance
No laser performance metrics recorded recently.
๐ฌ Optical Resolution (PSF & Alignment)
No recent PSF or chromatic shift metrics available for any objectives.
Objectives without recent data
-
Plan UW 2x/0.06 2x/0.06 AIR (
2x_air) -
Plan Fluor 4x/0.13 4x/0.13 AIR (
4x_air) -
Plan Apo ฮปD 4x/0.20 4x/0.2 AIR (
4x_air_2) -
Plan Fluor 10x/0.30 OFN 25 Ph1 DL 10x/0.3 AIR (
10x_air) -
S Plan Fluor ELWD ADM 20x/0.45 DIC N1 20x/0.45 AIR (
20x_air) -
Plan Apo ฮป 20x/0.75 OFN25 DIC N2 20x/0.75 AIR (
20x_air_2) -
S Plan Fluor ELWD 40x/0.60 OFN22 Ph2 40x/0.6 AIR (
40x_air) -
Plan Apo ฮป 60x/1.40 Oil OFN25 DIC N2 60x/1.4 OIL (
60x_oil) -
Apo TIRF 100x/1.49 Oil 100x/1.49 OIL (
100x_oil)
Metadata Completeness
-
Missing required fields:
-
instrument.locationโ Location -
Legacy aliases in use (fallback accepted):
-
modules[].nameโmodules[].type -
hardware.detectors[].pixel_size_umโhardware.detectors[].pixel_pitch_um -
hardware.detectors[].min_nmโhardware.detectors[].collection_min_nm -
hardware.detectors[].max_nmโhardware.detectors[].collection_max_nm -
hardware.detectors[].channel_center_nmโhardware.detectors[].collection_center_nm -
hardware.detectors[].bandwidth_nmโhardware.detectors[].collection_width_nm