Olympus BX60

About this microscope

Here you’ll find the hardware and capabilities currently recorded for this microscope. If you are planning an experiment, AIC Turku staff can help with access, training, and configuration choices.

Current status: 🟢 Online

Operational

QC and maintenance history Open Virtual Microscope

Olympus BX60 microscope
Manufacturer
Olympus/Evident
Model
BX60
Stand
Upright
Eyepieces
Trinocular
Location
MediCity, BioCity 4th floor, room 4086
Purchased
—
Funding
—
Capabilities
These are the capabilities recorded for this microscope. Open the optical-route details below to see how the hardware is connected.
Widefield fluorescenceTransmitted brightfieldPhase contrast
Methods and the light path that records them
Each method below is explicitly associated in the instrument record with the physical light path that implements it. An imaging mode or contrast method that appears above but not here has no recorded method-to-path mapping yet.
  • Widefield fluorescence: Widefield fluorescence
  • Transmitted light: Transmitted brightfield, Phase contrast


Software

  • Olympus Cell^D
    Acquisition
    Role: Acquisition
    Version: Not documented

Hardware

Light sources

  • Halogen Lamp Olympus 12V 100W halogen bulb
    Olympus
    Type: Halogen Lamp
    Role: Transmitted Illumination
    Power: 100 W
    Notes: Transmitted brightfield and phase contrast source. Broadband illumination.

  • Arc Lamp Osram HBO 103W short arc bulb
    Osram
    Type: Arc Lamp
    Power: 103 W
    Notes: Fluorescence excitation source. Broadband illumination.

Detectors

  • Olympus DP71
    Charge-Coupled Device
    Type: Charge-Coupled Device
    Pixel pitch: 6.45 µm
    Sensor format: 1.45 MP
    Notes: Manufacturer specifies 1.45 million effective sensor pixels; the physical array dimensions are not confirmed here. The documented live image format is 1360 x 1024 and pixel-shift output is 4080 x 3072; these output formats must not be used as physical sensor dimensions.

Objectives

View this microscope's objectives in the catalogue

  • PlanC 4x/0.10 AIR
    Olympus
    Model: PlanC 4x/0.10
    Magnification / NA: 4x/0.1
    Immersion: Air
    Correction: Plan Achromat
    Working distance: 18.5 mm
    AFC compatible: No
    Installed: Yes

  • UPlanFl 10x/0.30 Ph1 AIR
    Olympus
    Model: UPlanFl 10x/0.30 Ph1
    Magnification / NA: 10x/0.3
    Immersion: Air
    Correction: Plan Fluorite
    Working distance: 10.0 mm
    AFC compatible: No
    Installed: Yes
    Specialties: phase

  • UPlanFl 20x/0.50 Ph1 AIR
    Olympus
    Model: UPlanFl 20x/0.50 Ph1
    Magnification / NA: 20x/0.5
    Immersion: Air
    Correction: Plan Fluorite
    Working distance: 2.1 mm
    AFC compatible: No
    Installed: Yes
    Specialties: phase

  • UPlanFl 40x/0.75 Ph2 AIR
    Olympus
    Model: UPlanFl 40x/0.75 Ph2
    Magnification / NA: 40x/0.75
    Immersion: Air
    Correction: Plan Fluorite
    Working distance: 0.51 mm
    AFC compatible: No
    Installed: Yes
    Specialties: phase

  • UPlanApo 100x/1.35 Oil Iris Ph3 OIL
    Olympus
    Model: UPlanApo 100x/1.35 Oil Iris Ph3
    Magnification / NA: 100x/1.35
    Immersion: Oil
    Correction: Plan Apochromat
    Working distance: 0.17 mm
    AFC compatible: No
    Installed: Yes
    Specialties: phase
    Notes: Includes adjustable iris

  • UPlanFl 60x/1.25 Oil Iris Ph3 OILNot installed
    Olympus
    Model: UPlanFl 60x/1.25 Oil Iris Ph3
    Magnification / NA: 60x/1.25
    Immersion: Oil
    Correction: Plan Fluorite
    Working distance: 0.12 mm
    AFC compatible: No
    Installed: No
    Specialties: phase
    Notes: Optional objective. Includes adjustable iris. Working distance cross-checked against an exact UPlanFl 60x/1.25 Oil Iris Ph3 listing.

Optical-path elements

  • Fluorescence Turret
    Cube
    Element type: Turret
    Pos 1: U-MWU (DAPI) (U-MWU) — Excitation: 355/50 nm. Dichroic Cutoff: 400 nm.
    Pos 2: U-MWIB (GFP wide) (U-MWIB) — Excitation: 475/30 nm. Dichroic Cutoff: 505 nm.
    Pos 3: U-MWIG (Alexa 546 / TRITC) (U-MWIG) — Excitation: 535/30 nm. Dichroic Cutoff: 565 nm.
    Pos 4: U-MNIBA2 (GFP narrow) (U-MNIBA2) — emission 530/40 nm — Optional filter cube. Excitation: 480/20 nm. Dichroic Cutoff: 505 nm.

Latest QC measurements

Laser performance

No recent laser-performance measurements are recorded.

Optical resolution (PSF and alignment)

No recent PSF or chromatic-shift measurements are recorded for these objectives.

Objectives without recent measurements
  • PlanC 4x/0.10 AIR (4x_air)

  • UPlanFl 10x/0.30 Ph1 AIR (10x_air)

  • UPlanFl 20x/0.50 Ph1 AIR (20x_air)

  • UPlanFl 40x/0.75 Ph2 AIR (40x_air)

  • UPlanApo 100x/1.35 Oil Iris Ph3 OIL (100x_oil)

  • UPlanFl 60x/1.25 Oil Iris Ph3 OIL (60x_oil)

Information still to confirm

Some details in the facility record are incomplete. If any of these matter for your experiment, please check them with AIC Turku staff.

  • Details needed for this configuration:

  • Software version (software[].version)