Use this catalogue to compare objectives recorded on AIC Turku microscopes and in the spare pool. Filter by microscope, immersion, condition, or availability. If you are considering a spare or non-installed objective, AIC Turku staff can help check compatibility and arrange installation.
137 current source records: 102 associated with active microscopes and 35 in the spare pool (including calibration items). 2 historical records can be included below. These are source records, not counts of physical lenses. 8 spare-pool records have reported problems.
Contact AIC Turku staff · Download catalogue (JSON) · Spare-pool data only
Showing all 139 records, including historical records.
Objectives associated with microscopes may be installed, stored separately, or not yet confirmed. A non-installed objective is not automatically part of the shared spare pool.
No matching objectives. Try another search or .
Zeiss · Objective
Plan-Apochromat 10x/0.45 Ph1 M27
Installed - as recorded
3i CSU-W1 Spinning Disk
Product code: 420641-9910
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 10x
- Numerical aperture (NA)
- 0.45
- Immersion
- Air
- Working distance (as recorded)
- 2.0 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room 5149.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-3i-csu-w1-spinning-disk; objective: 10x_air
{
"id": "10x_air",
"manufacturer": "Zeiss",
"model": "Plan-Apochromat 10x/0.45 Ph1 M27",
"product_code": "420641-9910",
"magnification": 10.0,
"numerical_aperture": 0.45,
"working_distance": "2.0 mm",
"immersion": "air",
"correction": "plan_apochromat",
"afc_compatible": false,
"is_installed": true,
"specialties": [
"phase"
],
"url": "https://www.micro-shop.zeiss.com/en/us/shop/objectives/420641-9910-000/Objective-Plan-Apochromat-10x-0.45-Ph1-M27"
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-3i-csu-w1-spinning-disk--10x_air (catalogue ID, not a physical asset tag).
Zeiss · Objective
Plan-Apochromat 20x/0.8
Installed - as recorded
3i CSU-W1 Spinning Disk
Product code: 440640-9903-000
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 20x
- Numerical aperture (NA)
- 0.8
- Immersion
- Air
- Working distance (as recorded)
- 0.55 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room 5149.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-3i-csu-w1-spinning-disk; objective: 20x_air
{
"id": "20x_air",
"manufacturer": "Zeiss",
"model": "Plan-Apochromat 20x/0.8",
"product_code": "440640-9903-000",
"magnification": 20.0,
"numerical_aperture": 0.8,
"working_distance": "0.55 mm",
"immersion": "air",
"correction": "plan_apochromat",
"afc_compatible": false,
"is_installed": true,
"url": "https://www.micro-shop.zeiss.com/en/us/shop/objectives/440640-9903-000/Objective-Plan-Apochromat-20x-0.8"
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-3i-csu-w1-spinning-disk--20x_air (catalogue ID, not a physical asset tag).
Zeiss · Objective
LD C-APOCHROMAT 40x/1.1 W M27
Installed - as recorded
3i CSU-W1 Spinning Disk
Product code: 421867-9970
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 40x
- Numerical aperture (NA)
- 1.1
- Immersion
- Water
- Working distance (as recorded)
- 0.62 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room 5149.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-3i-csu-w1-spinning-disk; objective: 40x_water
{
"id": "40x_water",
"manufacturer": "Zeiss",
"model": "LD C-APOCHROMAT 40x/1.1 W M27",
"product_code": "421867-9970",
"magnification": 40.0,
"numerical_aperture": 1.1,
"working_distance": "0.62 mm",
"immersion": "water",
"correction": "apochromat",
"afc_compatible": false,
"is_installed": true,
"specialties": [
"coverslip_correction",
"ir_transmission"
],
"url": "https://www.micro-shop.zeiss.com/en/us/shop/objectives/421867-9970-000/Objective-LD-C-Apochromat-40x-1.1-W-Corr-M27"
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-3i-csu-w1-spinning-disk--40x_water (catalogue ID, not a physical asset tag).
Zeiss · Objective
Plan-Apochromat 63x/1.4 Oil DIC M27
Installed - as recorded
3i CSU-W1 Spinning Disk
Product code: 420782-9900
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 63x
- Numerical aperture (NA)
- 1.4
- Immersion
- Oil
- Working distance (as recorded)
- 0.19 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room 5149.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-3i-csu-w1-spinning-disk; objective: 63x_oil
{
"id": "63x_oil",
"manufacturer": "Zeiss",
"model": "Plan-Apochromat 63x/1.4 Oil DIC M27",
"product_code": "420782-9900",
"magnification": 63.0,
"numerical_aperture": 1.4,
"working_distance": "0.19 mm",
"immersion": "oil",
"correction": "plan_apochromat",
"afc_compatible": false,
"is_installed": true,
"specialties": [
"dic"
],
"url": "https://www.micro-shop.zeiss.com/en/us/shop/objectives/420782-9900-799/Objective-Plan-Apochromat-63x-1.4-Oil-DIC-M27"
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-3i-csu-w1-spinning-disk--63x_oil (catalogue ID, not a physical asset tag).
Zeiss · Objective
Plan-Apochromat 100x/1.4 Oil DIC M27
Installed - as recorded
3i CSU-W1 Spinning Disk
Product code: 420792-9901
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 100x
- Numerical aperture (NA)
- 1.4
- Immersion
- Oil
- Working distance (as recorded)
- 0.17 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room 5149.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-3i-csu-w1-spinning-disk; objective: 100x_oil
{
"id": "100x_oil",
"manufacturer": "Zeiss",
"model": "Plan-Apochromat 100x/1.4 Oil DIC M27",
"product_code": "420792-9901",
"magnification": 100.0,
"numerical_aperture": 1.4,
"working_distance": "0.17 mm",
"immersion": "oil",
"correction": "plan_apochromat",
"afc_compatible": false,
"is_installed": true,
"specialties": [
"dic"
],
"url": "https://www.micro-shop.zeiss.com/en/us/shop/objectives/420792-9901-000/Objective-Plan-Apochromat-100x-1.4-Oil-DIC-M27"
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-3i-csu-w1-spinning-disk--100x_oil (catalogue ID, not a physical asset tag).
Zeiss · Objective
LD LCI Plan-APOCHROMAT 25x/0.8 Imm Korr DIC (UV)VIS-IR
Associated - not installed
3i CSU-W1 Spinning Disk
Product code: 420852-9871
Recorded note: Optional objective. Multi-immersion correction-collar objective.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 25x
- Numerical aperture (NA)
- 0.8
- Immersion
- Multi-Immersion
- Working distance (as recorded)
- 0.57 mm at cover glass 0.17
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room 5149.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-3i-csu-w1-spinning-disk; objective: 25x_multi
{
"id": "25x_multi",
"manufacturer": "Zeiss",
"model": "LD LCI Plan-APOCHROMAT 25x/0.8 Imm Korr DIC (UV)VIS-IR",
"product_code": "420852-9871",
"magnification": 25.0,
"numerical_aperture": 0.8,
"working_distance": "0.57 mm at cover glass 0.17",
"immersion": "multi",
"correction": "plan_apochromat",
"afc_compatible": false,
"is_installed": false,
"specialties": [
"dic",
"ir_transmission",
"correction_collar"
],
"notes": "Optional objective. Multi-immersion correction-collar objective.",
"url": "https://www.micro-shop.zeiss.com/en/us/shop/objectives/420852-9871-799/Objective-LD-LCI-Plan-Apochromat-25x-0.8-Imm-Corr-DIC-M27"
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-3i-csu-w1-spinning-disk--25x_multi (catalogue ID, not a physical asset tag).
Zeiss · Objective
C-APOCHROMAT 63x/1.2 W Korr UV-VIS-IR
Associated - not installed
3i CSU-W1 Spinning Disk
Product code: 421787-9970
Recorded note: Optional objective. Water-immersion correction-collar objective.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 63x
- Numerical aperture (NA)
- 1.2
- Immersion
- Water
- Working distance (as recorded)
- 0.28 mm at cover glass 0.17
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room 5149.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-3i-csu-w1-spinning-disk; objective: 63x_water_c_apo
{
"id": "63x_water_c_apo",
"manufacturer": "Zeiss",
"model": "C-APOCHROMAT 63x/1.2 W Korr UV-VIS-IR",
"product_code": "421787-9970",
"magnification": 63.0,
"numerical_aperture": 1.2,
"working_distance": "0.28 mm at cover glass 0.17",
"immersion": "water",
"correction": "apochromat",
"afc_compatible": false,
"is_installed": false,
"specialties": [
"ir_transmission",
"correction_collar"
],
"notes": "Optional objective. Water-immersion correction-collar objective.",
"url": "https://www.micro-shop.zeiss.com/en/us/shop/objectives/421787-9970-799/Objective-C-Apochromat-63x-1.2-W-Corr-M27"
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-3i-csu-w1-spinning-disk--63x_water_c_apo (catalogue ID, not a physical asset tag).
Zeiss · Objective
EC Plan-Neofluar 5x/0.16 NA Ph1
Installed - as recorded
3i Marianas CSU-W1 Spinning Disk Med C
Product code: 420331-9911-000
Recorded note: Ph1. Without immersion.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 5x
- Numerical aperture (NA)
- 0.16
- Immersion
- Air
- Working distance (as recorded)
- 18.5 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: Medisiina C, 2nd floor, room C242.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-3i-csu-w1-spinning-disk-med-c; objective: 5x_air
{
"id": "5x_air",
"manufacturer": "Zeiss",
"model": "EC Plan-Neofluar 5x/0.16 NA Ph1",
"product_code": "420331-9911-000",
"magnification": 5.0,
"numerical_aperture": 0.16,
"working_distance": "18.5 mm",
"immersion": "air",
"correction": "plan_fluorite",
"afc_compatible": false,
"is_installed": true,
"specialties": [
"phase"
],
"notes": "Ph1. Without immersion.",
"url": "https://www.micro-shop.zeiss.com/en/us/shop/objectives/420331-9911-000/Objective-EC-Plan-Neofluar-5x-0.16-Ph1-M27"
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-3i-csu-w1-spinning-disk-med-c--5x_air (catalogue ID, not a physical asset tag).
Zeiss · Objective
Plan-Apochromat 10x/0.45 NA Ph1
Installed - as recorded
3i Marianas CSU-W1 Spinning Disk Med C
Product code: 420641-9910-000
Recorded note: Ph1. Without immersion.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 10x
- Numerical aperture (NA)
- 0.45
- Immersion
- Air
- Working distance (as recorded)
- 2.0 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: Medisiina C, 2nd floor, room C242.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-3i-csu-w1-spinning-disk-med-c; objective: 10x_air
{
"id": "10x_air",
"manufacturer": "Zeiss",
"model": "Plan-Apochromat 10x/0.45 NA Ph1",
"product_code": "420641-9910-000",
"magnification": 10.0,
"numerical_aperture": 0.45,
"working_distance": "2.0 mm",
"immersion": "air",
"correction": "plan_apochromat",
"afc_compatible": false,
"is_installed": true,
"specialties": [
"phase"
],
"notes": "Ph1. Without immersion.",
"url": "https://www.micro-shop.zeiss.com/en/us/shop/objectives/420641-9910-000/Objective-Plan-Apochromat-10x-0.45-Ph1-M27"
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-3i-csu-w1-spinning-disk-med-c--10x_air (catalogue ID, not a physical asset tag).
Zeiss · Objective
Plan-Apochromat 20x/0.8 NA
Installed - as recorded
3i Marianas CSU-W1 Spinning Disk Med C
Product code: 420650-9902-000
Recorded note: Without immersion.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 20x
- Numerical aperture (NA)
- 0.8
- Immersion
- Air
- Working distance (as recorded)
- 0.55 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: Medisiina C, 2nd floor, room C242.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-3i-csu-w1-spinning-disk-med-c; objective: 20x_air
{
"id": "20x_air",
"manufacturer": "Zeiss",
"model": "Plan-Apochromat 20x/0.8 NA",
"product_code": "420650-9902-000",
"magnification": 20.0,
"numerical_aperture": 0.8,
"working_distance": "0.55 mm",
"immersion": "air",
"correction": "plan_apochromat",
"afc_compatible": true,
"is_installed": true,
"notes": "Without immersion.",
"url": "https://www.micro-shop.zeiss.com/en/us/shop/objectives/420650-9902-000/Objective-Plan-Apochromat-20x-0.8-M27"
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-3i-csu-w1-spinning-disk-med-c--20x_air (catalogue ID, not a physical asset tag).
Zeiss · Objective
LD Plan-Neofluar 20x/0.4 NA Corr
Installed - as recorded
3i Marianas CSU-W1 Spinning Disk Med C
Product code: 421350-9971-000
Recorded note: Correction collar for 0-1.5 mm glass. Without immersion.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 20x
- Numerical aperture (NA)
- 0.4
- Immersion
- Air
- Working distance (as recorded)
- 7.9 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: Medisiina C, 2nd floor, room C242.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-3i-csu-w1-spinning-disk-med-c; objective: 20x_air_2
{
"id": "20x_air_2",
"manufacturer": "Zeiss",
"model": "LD Plan-Neofluar 20x/0.4 NA Corr",
"product_code": "421350-9971-000",
"magnification": 20.0,
"numerical_aperture": 0.4,
"working_distance": "7.9 mm",
"immersion": "air",
"correction": "plan_fluorite",
"afc_compatible": true,
"is_installed": true,
"specialties": [
"correction_collar"
],
"notes": "Correction collar for 0-1.5 mm glass. Without immersion.",
"url": "https://www.micro-shop.zeiss.com/en/us/shop/objectives/421350-9971-000/Objective-LD-Plan-Neofluar-20x-0.4-Corr-M27"
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-3i-csu-w1-spinning-disk-med-c--20x_air_2 (catalogue ID, not a physical asset tag).
Zeiss · Objective
LD Plan-Neofluar 40x/0.6 NA Corr
Installed - as recorded
3i Marianas CSU-W1 Spinning Disk Med C
Product code: 421360-9971-000
Recorded note: Correction collar for 0-1.5 mm glass. Without immersion.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 40x
- Numerical aperture (NA)
- 0.6
- Immersion
- Air
- Working distance (as recorded)
- 2.9 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: Medisiina C, 2nd floor, room C242.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-3i-csu-w1-spinning-disk-med-c; objective: 40x_air
{
"id": "40x_air",
"manufacturer": "Zeiss",
"model": "LD Plan-Neofluar 40x/0.6 NA Corr",
"product_code": "421360-9971-000",
"magnification": 40.0,
"numerical_aperture": 0.6,
"working_distance": "2.9 mm",
"immersion": "air",
"correction": "plan_fluorite",
"afc_compatible": true,
"is_installed": true,
"specialties": [
"correction_collar"
],
"notes": "Correction collar for 0-1.5 mm glass. Without immersion.",
"url": "https://www.micro-shop.zeiss.com/en/no/shop/objectives/421360-9971-000/Objective-LD-Plan-Neofluar-40x-0.6-Corr-M27"
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-3i-csu-w1-spinning-disk-med-c--40x_air (catalogue ID, not a physical asset tag).
Zeiss · Objective
C-Apochromat 40x/1.2 W Corr
Installed - as recorded
3i Marianas CSU-W1 Spinning Disk Med C
Product code: 421767-9970-000
Recorded note: Correction ring for 0.17 mm cover glass. Immersion: Water.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 40x
- Numerical aperture (NA)
- 1.2
- Immersion
- Water
- Working distance (as recorded)
- 0.28 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: Medisiina C, 2nd floor, room C242.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-3i-csu-w1-spinning-disk-med-c; objective: 40x_water
{
"id": "40x_water",
"manufacturer": "Zeiss",
"model": "C-Apochromat 40x/1.2 W Corr",
"product_code": "421767-9970-000",
"magnification": 40.0,
"numerical_aperture": 1.2,
"working_distance": "0.28 mm",
"immersion": "water",
"correction": "apochromat",
"afc_compatible": true,
"is_installed": true,
"specialties": [
"correction_collar"
],
"notes": "Correction ring for 0.17 mm cover glass. Immersion: Water.",
"url": "https://www.micro-shop.zeiss.com/en/us/shop/objectives/421767-9970-000/Objective-C-Apochromat-40x-1.2-W-Corr-M27"
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-3i-csu-w1-spinning-disk-med-c--40x_water (catalogue ID, not a physical asset tag).
Zeiss · Objective
Plan-Apochromat 63x/1.4 NA Oil
Installed - as recorded
3i Marianas CSU-W1 Spinning Disk Med C
Product code: 420780-9900-000
Recorded note: Immersion: Oil.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 63x
- Numerical aperture (NA)
- 1.4
- Immersion
- Oil
- Working distance (as recorded)
- 0.19 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: Medisiina C, 2nd floor, room C242.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-3i-csu-w1-spinning-disk-med-c; objective: 63x_oil
{
"id": "63x_oil",
"manufacturer": "Zeiss",
"model": "Plan-Apochromat 63x/1.4 NA Oil",
"product_code": "420780-9900-000",
"magnification": 63.0,
"numerical_aperture": 1.4,
"working_distance": "0.19 mm",
"immersion": "oil",
"correction": "plan_apochromat",
"afc_compatible": true,
"is_installed": true,
"notes": "Immersion: Oil.",
"url": "https://www.micro-shop.zeiss.com/en/us/shop/objectives/420780-9900-000/Objective-Plan-Apochromat-63x-1.4-Oil-M27"
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-3i-csu-w1-spinning-disk-med-c--63x_oil (catalogue ID, not a physical asset tag).
Zeiss · Objective
alpha Plan-Apochromat 100x/1.46 NA Oil DIC
Installed - as recorded
3i Marianas CSU-W1 Spinning Disk Med C
Product code: 420792-9800-000
Recorded note: Immersion: Oil.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 100x
- Numerical aperture (NA)
- 1.46
- Immersion
- Oil
- Working distance (as recorded)
- 0.11 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: Medisiina C, 2nd floor, room C242.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-3i-csu-w1-spinning-disk-med-c; objective: 100x_oil
{
"id": "100x_oil",
"manufacturer": "Zeiss",
"model": "alpha Plan-Apochromat 100x/1.46 NA Oil DIC",
"product_code": "420792-9800-000",
"magnification": 100.0,
"numerical_aperture": 1.46,
"working_distance": "0.11 mm",
"immersion": "oil",
"correction": "plan_apochromat",
"afc_compatible": true,
"is_installed": true,
"specialties": [
"dic"
],
"notes": "Immersion: Oil.",
"url": "https://www.micro-shop.zeiss.com/en/us/shop/objectives/420792-9800-000/Objective-alpha-Plan-Apochromat-100x-1.46-Oil-DIC-M27"
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-3i-csu-w1-spinning-disk-med-c--100x_oil (catalogue ID, not a physical asset tag).
Olympus · Objective
LMPlanFL N 20x/0.40
Installed - as recorded
Abberior STED
Product code: 1-U2N345
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 20x
- Numerical aperture (NA)
- 0.4
- Immersion
- Air
- Working distance (as recorded)
- 12.0 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, BioPhysics room 5086.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-1e33f909; objective: 20x_air
{
"id": "20x_air",
"manufacturer": "Olympus",
"model": "LMPlanFL N 20x/0.40",
"product_code": "1-U2N345",
"magnification": 20.0,
"numerical_aperture": 0.4,
"working_distance": "12.0 mm",
"immersion": "air",
"correction": "plan_fluorite",
"is_installed": true
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-1e33f909--20x_air (catalogue ID, not a physical asset tag).
Olympus · Objective
UPlanSApo 60x/1.2 W
Installed - as recorded
Abberior STED
Product code: N6432600
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 60x
- Numerical aperture (NA)
- 1.2
- Immersion
- Water
- Working distance (as recorded)
- 0.28 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, BioPhysics room 5086.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-1e33f909; objective: 60x_water
{
"id": "60x_water",
"manufacturer": "Olympus",
"model": "UPlanSApo 60x/1.2 W",
"product_code": "N6432600",
"magnification": 60.0,
"numerical_aperture": 1.2,
"working_distance": "0.28 mm",
"immersion": "water",
"correction": "plan_apochromat",
"is_installed": true
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-1e33f909--60x_water (catalogue ID, not a physical asset tag).
Olympus · Objective
UPlanSApo 100x/1.40 Oil
Installed - as recorded
Abberior STED
Product code: 1-U2B836
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 100x
- Numerical aperture (NA)
- 1.4
- Immersion
- Oil
- Working distance (as recorded)
- 0.13 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, BioPhysics room 5086.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-1e33f909; objective: 100x_oil
{
"id": "100x_oil",
"manufacturer": "Olympus",
"model": "UPlanSApo 100x/1.40 Oil",
"product_code": "1-U2B836",
"magnification": 100.0,
"numerical_aperture": 1.4,
"working_distance": "0.13 mm",
"immersion": "oil",
"correction": "plan_apochromat",
"is_installed": true
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-1e33f909--100x_oil (catalogue ID, not a physical asset tag).
Agilent · Objective
10x Objective
Installed - as recorded
Agilent xCELLigence RTCA eSight
Product code: Not recorded
Recorded note: Default. Resolution: 1.72 µm/pixel. FOV: 1.68 x 1.40 mm.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 10x
- Numerical aperture (NA)
- 0.3
- Immersion
- Air
- Working distance (as recorded)
- Not recorded
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-agilent-rtca-esight; objective: 10x_air
{
"id": "10x_air",
"manufacturer": "Agilent",
"model": "10x Objective",
"magnification": 10.0,
"numerical_aperture": 0.3,
"immersion": "air",
"correction": "plan_achromat",
"afc_compatible": true,
"is_installed": true,
"notes": "Default. Resolution: 1.72 µm/pixel. FOV: 1.68 x 1.40 mm."
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-agilent-rtca-esight--10x_air (catalogue ID, not a physical asset tag).
Andor · Objective
2X Plan Achromat
Installed - as recorded
Andor BC43 Benchtop Confocal
Product code: INS-OBJ-02-006
Recorded note: Included with the BC43 base system.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 2x
- Numerical aperture (NA)
- 0.06
- Immersion
- Air
- Working distance (as recorded)
- 7.5 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room 5149.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-andor-bc43; objective: 2x_air
{
"id": "2x_air",
"manufacturer": "Andor",
"model": "2X Plan Achromat",
"product_code": "INS-OBJ-02-006",
"magnification": 2.0,
"numerical_aperture": 0.06,
"working_distance": "7.5 mm",
"immersion": "air",
"correction": "plan_achromat",
"afc_compatible": true,
"is_installed": true,
"notes": "Included with the BC43 base system."
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-andor-bc43--2x_air (catalogue ID, not a physical asset tag).
Nikon · Objective
10X Plan Apo LD Air
Installed - as recorded
Andor BC43 Benchtop Confocal
Product code: INS-OBJ-10D-045
Recorded note: Optical family: Lambda D.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 10x
- Numerical aperture (NA)
- 0.45
- Immersion
- Air
- Working distance (as recorded)
- 4.0 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room 5149.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-andor-bc43; objective: 10x_air
{
"id": "10x_air",
"manufacturer": "Nikon",
"model": "10X Plan Apo LD Air",
"product_code": "INS-OBJ-10D-045",
"magnification": 10.0,
"numerical_aperture": 0.45,
"working_distance": "4.0 mm",
"immersion": "air",
"correction": "plan_apochromat",
"afc_compatible": true,
"is_installed": true,
"notes": "Optical family: Lambda D."
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-andor-bc43--10x_air (catalogue ID, not a physical asset tag).
Nikon · Objective
20X Plan Apo LD Air
Installed - as recorded
Andor BC43 Benchtop Confocal
Product code: INS-OBJ-20D-080
Recorded note: Optical family: Lambda D.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 20x
- Numerical aperture (NA)
- 0.8
- Immersion
- Air
- Working distance (as recorded)
- 0.8 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room 5149.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-andor-bc43; objective: 20x_air
{
"id": "20x_air",
"manufacturer": "Nikon",
"model": "20X Plan Apo LD Air",
"product_code": "INS-OBJ-20D-080",
"magnification": 20.0,
"numerical_aperture": 0.8,
"working_distance": "0.8 mm",
"immersion": "air",
"correction": "plan_apochromat",
"afc_compatible": true,
"is_installed": true,
"notes": "Optical family: Lambda D."
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-andor-bc43--20x_air (catalogue ID, not a physical asset tag).
Nikon · Objective
40X Plan Apo LD Air
Installed - as recorded
Andor BC43 Benchtop Confocal
Product code: INS-OBJ-40D-095
Recorded note: Optical family: Lambda D.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 40x
- Numerical aperture (NA)
- 0.95
- Immersion
- Air
- Working distance (as recorded)
- 0.21 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room 5149.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-andor-bc43; objective: 40x_air
{
"id": "40x_air",
"manufacturer": "Nikon",
"model": "40X Plan Apo LD Air",
"product_code": "INS-OBJ-40D-095",
"magnification": 40.0,
"numerical_aperture": 0.95,
"working_distance": "0.21 mm",
"immersion": "air",
"correction": "plan_apochromat",
"afc_compatible": true,
"is_installed": true,
"notes": "Optical family: Lambda D."
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-andor-bc43--40x_air (catalogue ID, not a physical asset tag).
Nikon · Objective
40X Plan Apo LS Sil Oil
Installed - as recorded
Andor BC43 Benchtop Confocal
Product code: INS-OBJ-40S-125-SIL
Recorded note: Optical family: Lambda S.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 40x
- Numerical aperture (NA)
- 1.25
- Immersion
- Silicone
- Working distance (as recorded)
- 0.3 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room 5149.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-andor-bc43; objective: 40x_silicone
{
"id": "40x_silicone",
"manufacturer": "Nikon",
"model": "40X Plan Apo LS Sil Oil",
"product_code": "INS-OBJ-40S-125-SIL",
"magnification": 40.0,
"numerical_aperture": 1.25,
"working_distance": "0.3 mm",
"immersion": "silicone",
"correction": "plan_apochromat",
"afc_compatible": true,
"is_installed": true,
"notes": "Optical family: Lambda S."
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-andor-bc43--40x_silicone (catalogue ID, not a physical asset tag).
Nikon · Objective
60X Plan Apo LD Oil
Installed - as recorded
Andor BC43 Benchtop Confocal
Product code: INS-OBJ-60D-142-O
Recorded note: Optical family: Lambda D.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 60x
- Numerical aperture (NA)
- 1.42
- Immersion
- Oil
- Working distance (as recorded)
- 0.15 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room 5149.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-andor-bc43; objective: 60x_oil
{
"id": "60x_oil",
"manufacturer": "Nikon",
"model": "60X Plan Apo LD Oil",
"product_code": "INS-OBJ-60D-142-O",
"magnification": 60.0,
"numerical_aperture": 1.42,
"working_distance": "0.15 mm",
"immersion": "oil",
"correction": "plan_apochromat",
"afc_compatible": true,
"is_installed": true,
"notes": "Optical family: Lambda D."
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-andor-bc43--60x_oil (catalogue ID, not a physical asset tag).
Nikon · Objective
100x Plan Apo LD Oil
Installed - as recorded
Andor BC43 Benchtop Confocal
Product code: INS-OBJ-100D-145-O
Recorded note: Optical family: Lambda D.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 100x
- Numerical aperture (NA)
- 1.45
- Immersion
- Oil
- Working distance (as recorded)
- 0.13 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room 5149.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-andor-bc43; objective: 100x_oil
{
"id": "100x_oil",
"manufacturer": "Nikon",
"model": "100x Plan Apo LD Oil",
"product_code": "INS-OBJ-100D-145-O",
"magnification": 100.0,
"numerical_aperture": 1.45,
"working_distance": "0.13 mm",
"immersion": "oil",
"correction": "plan_apochromat",
"afc_compatible": true,
"is_installed": true,
"notes": "Optical family: Lambda D."
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-andor-bc43--100x_oil (catalogue ID, not a physical asset tag).
Olympus · Objective
Plan Apo N
Associated - not installed
Deltavision OMX
Product code: Not recorded
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 60x
- Numerical aperture (NA)
- 1.42
- Immersion
- Oil
- Working distance (as recorded)
- 0.15 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room 5149.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-deltavision-omx; objective: 60x_oil
{
"id": "60x_oil",
"manufacturer": "Olympus",
"model": "Plan Apo N",
"magnification": 60.0,
"numerical_aperture": 1.42,
"working_distance": "0.15 mm",
"immersion": "oil",
"correction": "plan_apochromat",
"afc_compatible": false,
"is_installed": false,
"specialties": [
"sim"
]
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-deltavision-omx--60x_oil (catalogue ID, not a physical asset tag).
Olympus · Objective
APO N TIRF
Installed - as recorded
Deltavision OMX
Product code: Not recorded
Recorded note: Equipped with correction collar.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 60x
- Numerical aperture (NA)
- 1.49
- Immersion
- Oil
- Working distance (as recorded)
- 0.10 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room 5149.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-deltavision-omx; objective: 60x_oil_2
{
"id": "60x_oil_2",
"manufacturer": "Olympus",
"model": "APO N TIRF",
"magnification": 60.0,
"numerical_aperture": 1.49,
"working_distance": "0.10 mm",
"immersion": "oil",
"correction": "apochromat",
"afc_compatible": false,
"is_installed": true,
"specialties": [
"tirf"
],
"notes": "Equipped with correction collar."
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-deltavision-omx--60x_oil_2 (catalogue ID, not a physical asset tag).
Olympus · Objective
U Plan FL N 4x/0.13 PhP
Installed - as recorded
EVOS fl
Product code: Not recorded
Recorded note: PhP
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 4x
- Numerical aperture (NA)
- 0.13
- Immersion
- Air
- Working distance (as recorded)
- 16.4 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: Local Cell Culture Lab, Biocity 5th Floor.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-evos-fl; objective: 4x_air
{
"id": "4x_air",
"manufacturer": "Olympus",
"model": "U Plan FL N 4x/0.13 PhP",
"magnification": 4.0,
"numerical_aperture": 0.13,
"working_distance": "16.4 mm",
"immersion": "air",
"correction": "fluorite",
"afc_compatible": false,
"is_installed": true,
"specialties": [
"phase"
],
"notes": "PhP"
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-evos-fl--4x_air (catalogue ID, not a physical asset tag).
AMG (Thermo Fisher) · Objective
Plan Fluor 10x/0.3
Installed - as recorded
EVOS fl
Product code: AMG-AMEP 4623
Recorded note: Fluorite (FL)
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 10x
- Numerical aperture (NA)
- 0.3
- Immersion
- Air
- Working distance (as recorded)
- 8.3 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: Local Cell Culture Lab, Biocity 5th Floor.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-evos-fl; objective: 10x_air
{
"id": "10x_air",
"manufacturer": "AMG (Thermo Fisher)",
"model": "Plan Fluor 10x/0.3",
"product_code": "AMG-AMEP 4623",
"magnification": 10.0,
"numerical_aperture": 0.3,
"working_distance": "8.3 mm",
"immersion": "air",
"correction": "plan_fluorite",
"afc_compatible": false,
"is_installed": true,
"notes": "Fluorite (FL)"
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-evos-fl--10x_air (catalogue ID, not a physical asset tag).
AMG (Thermo Fisher) · Objective
Plan Fluor 20x/0.45
Installed - as recorded
EVOS fl
Product code: AMG-AMEP 4624
Recorded note: Fluorite (FL)
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 20x
- Numerical aperture (NA)
- 0.45
- Immersion
- Air
- Working distance (as recorded)
- 7.1 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: Local Cell Culture Lab, Biocity 5th Floor.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-evos-fl; objective: 20x_air
{
"id": "20x_air",
"manufacturer": "AMG (Thermo Fisher)",
"model": "Plan Fluor 20x/0.45",
"product_code": "AMG-AMEP 4624",
"magnification": 20.0,
"numerical_aperture": 0.45,
"working_distance": "7.1 mm",
"immersion": "air",
"correction": "plan_fluorite",
"afc_compatible": false,
"is_installed": true,
"notes": "Fluorite (FL)"
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-evos-fl--20x_air (catalogue ID, not a physical asset tag).
AMG (Thermo Fisher) · Objective
Plan Fluor 40x/0.65
Installed - as recorded
EVOS fl
Product code: AMG-AMEP 4625
Recorded note: Fluorite (FL)
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 40x
- Numerical aperture (NA)
- 0.65
- Immersion
- Air
- Working distance (as recorded)
- 2.8 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: Local Cell Culture Lab, Biocity 5th Floor.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-evos-fl; objective: 40x_air
{
"id": "40x_air",
"manufacturer": "AMG (Thermo Fisher)",
"model": "Plan Fluor 40x/0.65",
"product_code": "AMG-AMEP 4625",
"magnification": 40.0,
"numerical_aperture": 0.65,
"working_distance": "2.8 mm",
"immersion": "air",
"correction": "plan_fluorite",
"afc_compatible": false,
"is_installed": true,
"notes": "Fluorite (FL)"
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-evos-fl--40x_air (catalogue ID, not a physical asset tag).
Zeiss · Objective
LD-Plan NEOFLUAR 20x/0.4 Ph2 Korr
Installed - as recorded
Lambert FLIM
Product code: 421351-9970
Recorded note: Korr (correction collar)
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 20x
- Numerical aperture (NA)
- 0.4
- Immersion
- Air
- Working distance (as recorded)
- 7.9 mm at cover glass 0.75
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room 5149.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-lambert-flim-frequency-domain; objective: 20x_air_ph2
{
"id": "20x_air_ph2",
"manufacturer": "Zeiss",
"model": "LD-Plan NEOFLUAR 20x/0.4 Ph2 Korr",
"product_code": "421351-9970",
"magnification": 20.0,
"numerical_aperture": 0.4,
"working_distance": "7.9 mm at cover glass 0.75",
"immersion": "air",
"correction": "plan_fluorite",
"afc_compatible": false,
"is_installed": true,
"specialties": [
"phase",
"correction_collar"
],
"notes": "Korr (correction collar)",
"url": "https://www.micro-shop.zeiss.com/en/ts/shop/objectives/421351-9970-000/Objective-LD-Plan-Neofluar-20x-0.4-Corr-Ph2-M27"
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-lambert-flim-frequency-domain--20x_air_ph2 (catalogue ID, not a physical asset tag).
Zeiss · Objective
LD Plan-Neofluar 40x/0.6 Corr Ph2 M27
Installed - as recorded
Lambert FLIM
Product code: 421361-9970
Recorded note: Korr (correction collar)
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 40x
- Numerical aperture (NA)
- 0.6
- Immersion
- Air
- Working distance (as recorded)
- 2.9 mm at cover glass 0.75
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room 5149.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-lambert-flim-frequency-domain; objective: 40x_air_ph2
{
"id": "40x_air_ph2",
"manufacturer": "Zeiss",
"model": "LD Plan-Neofluar 40x/0.6 Corr Ph2 M27",
"product_code": "421361-9970",
"magnification": 40.0,
"numerical_aperture": 0.6,
"working_distance": "2.9 mm at cover glass 0.75",
"immersion": "air",
"correction": "plan_fluorite",
"afc_compatible": false,
"is_installed": true,
"specialties": [
"phase",
"correction_collar"
],
"notes": "Korr (correction collar)",
"url": "https://www.micro-shop.zeiss.com/zh/us/shop/objectives/421361-9970-000/Objective-LD-Plan-Neofluar-40x-0.6-Corr-Ph2-M27"
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-lambert-flim-frequency-domain--40x_air_ph2 (catalogue ID, not a physical asset tag).
Zeiss · Objective
Plan APOCHROMAT 63x/1.4 Oil
Installed - as recorded
Lambert FLIM
Product code: 420780-9900
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 63x
- Numerical aperture (NA)
- 1.4
- Immersion
- Oil
- Working distance (as recorded)
- 0.19 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room 5149.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-lambert-flim-frequency-domain; objective: 63x_oil
{
"id": "63x_oil",
"manufacturer": "Zeiss",
"model": "Plan APOCHROMAT 63x/1.4 Oil",
"product_code": "420780-9900",
"magnification": 63.0,
"numerical_aperture": 1.4,
"working_distance": "0.19 mm",
"immersion": "oil",
"correction": "plan_apochromat",
"afc_compatible": false,
"is_installed": true,
"url": "https://www.micro-shop.zeiss.com/en/us/shop/objectives/420780-9900-000/Objective-Plan-Apochromat-63x-1.4-Oil-M27"
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-lambert-flim-frequency-domain--63x_oil (catalogue ID, not a physical asset tag).
Leica · Objective
PL FLUOTAR 10x/0.30 PH1
Installed - as recorded
Leica DM IRBE
Product code: 506010
Recorded note: Working distance verified against an exact 506010 legacy objective listing.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 10x
- Numerical aperture (NA)
- 0.3
- Immersion
- Air
- Working distance (as recorded)
- 3.8 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 2nd floor, room 2076.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-leica-dm-irbe; objective: 10x_air
{
"id": "10x_air",
"manufacturer": "Leica",
"model": "PL FLUOTAR 10x/0.30 PH1",
"product_code": "506010",
"magnification": 10.0,
"numerical_aperture": 0.3,
"working_distance": "3.8 mm",
"immersion": "air",
"correction": "plan_fluorite",
"afc_compatible": false,
"is_installed": true,
"specialties": [
"phase"
],
"notes": "Working distance verified against an exact 506010 legacy objective listing.",
"url": "https://www.bristol.ac.uk/media-library/sites/wolfson-bioimaging/documents/widefield-4%20tech%20specs.pdf"
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-leica-dm-irbe--10x_air (catalogue ID, not a physical asset tag).
Leica · Objective
PL FLUOTAR 20x/0.50 PH2
Installed - as recorded
Leica DM IRBE
Product code: 506013
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 20x
- Numerical aperture (NA)
- 0.5
- Immersion
- Air
- Working distance (as recorded)
- Not recorded
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 2nd floor, room 2076.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-leica-dm-irbe; objective: 20x_air
{
"id": "20x_air",
"manufacturer": "Leica",
"model": "PL FLUOTAR 20x/0.50 PH2",
"product_code": "506013",
"magnification": 20.0,
"numerical_aperture": 0.5,
"immersion": "air",
"correction": "plan_fluorite",
"afc_compatible": false,
"is_installed": true,
"specialties": [
"phase"
]
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-leica-dm-irbe--20x_air (catalogue ID, not a physical asset tag).
Leica · Objective
PL FLUOTAR 40x/0.70 PH2
Installed - as recorded
Leica DM IRBE
Product code: 506014
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 40x
- Numerical aperture (NA)
- 0.7
- Immersion
- Air
- Working distance (as recorded)
- Not recorded
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 2nd floor, room 2076.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-leica-dm-irbe; objective: 40x_air
{
"id": "40x_air",
"manufacturer": "Leica",
"model": "PL FLUOTAR 40x/0.70 PH2",
"product_code": "506014",
"magnification": 40.0,
"numerical_aperture": 0.7,
"immersion": "air",
"correction": "plan_fluorite",
"afc_compatible": false,
"is_installed": true,
"specialties": [
"phase"
]
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-leica-dm-irbe--40x_air (catalogue ID, not a physical asset tag).
Leica · Objective
PL FLUOTAR 63x/0.70 CORR PH2
Installed - as recorded
Leica DM IRBE
Product code: 506062
Recorded note: Working-distance range cross-checked against an exact 506062 legacy objective listing.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 63x
- Numerical aperture (NA)
- 0.7
- Immersion
- Air
- Working distance (as recorded)
- 2.6-1.8 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 2nd floor, room 2076.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-leica-dm-irbe; objective: 63x_air
{
"id": "63x_air",
"manufacturer": "Leica",
"model": "PL FLUOTAR 63x/0.70 CORR PH2",
"product_code": "506062",
"magnification": 63.0,
"numerical_aperture": 0.7,
"working_distance": "2.6-1.8 mm",
"immersion": "air",
"correction": "plan_fluorite",
"afc_compatible": false,
"is_installed": true,
"specialties": [
"phase",
"correction_collar"
],
"notes": "Working-distance range cross-checked against an exact 506062 legacy objective listing.",
"url": "https://www.spachoptics.com/Leica-Pl-Fluotar-L-63x-PH2-Objective-p/leica-506062.htm"
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-leica-dm-irbe--63x_air (catalogue ID, not a physical asset tag).
Leica · Objective
PL FLUOTAR 10x/0.30
Installed - as recorded
Leica DM RB
Product code: 506000
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 10x
- Numerical aperture (NA)
- 0.3
- Immersion
- Air
- Working distance (as recorded)
- Not recorded
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 2nd floor, room 2076.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-leica-dm-rb; objective: 10x_air
{
"id": "10x_air",
"manufacturer": "Leica",
"model": "PL FLUOTAR 10x/0.30",
"product_code": "506000",
"magnification": 10.0,
"numerical_aperture": 0.3,
"immersion": "air",
"correction": "plan_fluorite",
"afc_compatible": false,
"is_installed": true
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-leica-dm-rb--10x_air (catalogue ID, not a physical asset tag).
Leica · Objective
HC PL APO 20x/0.70 CS
Installed - as recorded
Leica DM RB
Product code: 506513
Recorded note: Working distance cross-checked against Leica HCS legacy objective documentation for product 506513.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 20x
- Numerical aperture (NA)
- 0.7
- Immersion
- Air
- Working distance (as recorded)
- 0.59 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 2nd floor, room 2076.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-leica-dm-rb; objective: 20x_air
{
"id": "20x_air",
"manufacturer": "Leica",
"model": "HC PL APO 20x/0.70 CS",
"product_code": "506513",
"magnification": 20.0,
"numerical_aperture": 0.7,
"working_distance": "0.59 mm",
"immersion": "air",
"correction": "plan_apochromat",
"afc_compatible": false,
"is_installed": true,
"notes": "Working distance cross-checked against Leica HCS legacy objective documentation for product 506513.",
"url": "https://wie-tec.de/mediafiles/Sonstiges/Mikroskop/Leica/leica_delta_hc.pdf"
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-leica-dm-rb--20x_air (catalogue ID, not a physical asset tag).
Leica · Objective
PL FLUOTAR 40x/1.00-0.50 OIL
Installed - as recorded
Leica DM RB
Product code: 506007
Recorded note: NA range 1.00-0.50. Note that this has an adjustable iris diaphragm. Working distance matches the exact 506007 record in the AIC objective-pool source.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 40x
- Numerical aperture (NA)
- 1.0
- Immersion
- Oil
- Working distance (as recorded)
- 0.08 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 2nd floor, room 2076.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-leica-dm-rb; objective: 40x_oil
{
"id": "40x_oil",
"manufacturer": "Leica",
"model": "PL FLUOTAR 40x/1.00-0.50 OIL",
"product_code": "506007",
"magnification": 40.0,
"numerical_aperture": 1.0,
"working_distance": "0.08 mm",
"immersion": "oil",
"correction": "plan_fluorite",
"afc_compatible": false,
"is_installed": true,
"notes": "NA range 1.00-0.50. Note that this has an adjustable iris diaphragm. Working distance matches the exact 506007 record in the AIC objective-pool source."
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-leica-dm-rb--40x_oil (catalogue ID, not a physical asset tag).
Leica · Objective
HCX PL APO 63x/1.32-0.6 OIL
Installed - as recorded
Leica DM RB
Product code: 506180
Recorded note: NA range 1.32-0.6. Has an adjustable iris diaphragm for darkfield.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 63x
- Numerical aperture (NA)
- 1.32
- Immersion
- Oil
- Working distance (as recorded)
- Not recorded
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 2nd floor, room 2076.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-leica-dm-rb; objective: 63x_oil
{
"id": "63x_oil",
"manufacturer": "Leica",
"model": "HCX PL APO 63x/1.32-0.6 OIL",
"product_code": "506180",
"magnification": 63.0,
"numerical_aperture": 1.32,
"immersion": "oil",
"correction": "plan_apochromat",
"afc_compatible": false,
"is_installed": true,
"notes": "NA range 1.32-0.6. Has an adjustable iris diaphragm for darkfield."
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-leica-dm-rb--63x_oil (catalogue ID, not a physical asset tag).
Leica · Objective
PL APO 100x/1.40-0.7 OIL
Installed - as recorded
Leica DM RB
Product code: 506038
Recorded note: NA range 1.40-0.7. Has an adjustable iris diaphragm for darkfield.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 100x
- Numerical aperture (NA)
- 1.4
- Immersion
- Oil
- Working distance (as recorded)
- 0.09 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 2nd floor, room 2076.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-leica-dm-rb; objective: 100x_oil
{
"id": "100x_oil",
"manufacturer": "Leica",
"model": "PL APO 100x/1.40-0.7 OIL",
"product_code": "506038",
"magnification": 100.0,
"numerical_aperture": 1.4,
"working_distance": "0.09 mm",
"immersion": "oil",
"correction": "plan_apochromat",
"afc_compatible": false,
"is_installed": true,
"notes": "NA range 1.40-0.7. Has an adjustable iris diaphragm for darkfield.",
"url": "https://wie-tec.de/leica-microscope-objective-hcx-pl-apo-100x14007-oil-cs-506038"
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-leica-dm-rb--100x_oil (catalogue ID, not a physical asset tag).
Leica · Objective
HC PL FLUOTAR 10x/0.30 PH1
Installed - as recorded
Leica DM RE
Product code: 506507
Recorded note: The facility Leica DMRE getting-started record identifies the installed 10x as article 506507 with PH1. Independent exact-code specifications give an 11.0 mm working distance.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 10x
- Numerical aperture (NA)
- 0.3
- Immersion
- Air
- Working distance (as recorded)
- 11.0 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 2nd floor, room 2076.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-leica-dmre; objective: 10x_air
{
"id": "10x_air",
"manufacturer": "Leica",
"model": "HC PL FLUOTAR 10x/0.30 PH1",
"product_code": "506507",
"magnification": 10.0,
"numerical_aperture": 0.3,
"working_distance": "11.0 mm",
"immersion": "air",
"correction": "plan_fluorite",
"is_installed": true,
"specialties": [
"phase",
"dic"
],
"notes": "The facility Leica DMRE getting-started record identifies the installed 10x as article 506507 with PH1. Independent exact-code specifications give an 11.0 mm working distance.",
"url": "https://wie-tec.de/?a=17775&lang=eng"
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-leica-dmre--10x_air (catalogue ID, not a physical asset tag).
Leica · Objective
HC PL FLUOTAR 20x/0.50 PH2
Installed - as recorded
Leica DM RE
Product code: 506506
Recorded note: Working distance verified against an exact 506506 facility technical specification.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 20x
- Numerical aperture (NA)
- 0.5
- Immersion
- Air
- Working distance (as recorded)
- 1.15 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 2nd floor, room 2076.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-leica-dmre; objective: 20x_air
{
"id": "20x_air",
"manufacturer": "Leica",
"model": "HC PL FLUOTAR 20x/0.50 PH2",
"product_code": "506506",
"magnification": 20.0,
"numerical_aperture": 0.5,
"working_distance": "1.15 mm",
"immersion": "air",
"correction": "plan_fluorite",
"afc_compatible": false,
"is_installed": true,
"specialties": [
"phase",
"dic"
],
"notes": "Working distance verified against an exact 506506 facility technical specification.",
"url": "https://www.bristol.ac.uk/media-library/sites/wolfson-bioimaging/documents/TIRF.pdf"
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-leica-dmre--20x_air (catalogue ID, not a physical asset tag).
Leica · Objective
PL FLUOTAR 40x/0.70 PH2
Installed - as recorded
Leica DM RE
Product code: 506014
Recorded note: The facility DMRE getting-started record labels this installed 506014 objective as Ph3, but independent exact-code listings identify 506014 as Ph2, and facility staff confirmed Ph2 on 28 September 2026. The getting-started record is in error on this point. Working distance remains unknown.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 40x
- Numerical aperture (NA)
- 0.7
- Immersion
- Air
- Working distance (as recorded)
- Not recorded
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 2nd floor, room 2076.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-leica-dmre; objective: 40x_air
{
"id": "40x_air",
"manufacturer": "Leica",
"model": "PL FLUOTAR 40x/0.70 PH2",
"product_code": "506014",
"magnification": 40.0,
"numerical_aperture": 0.7,
"immersion": "air",
"correction": "plan_fluorite",
"afc_compatible": false,
"is_installed": true,
"specialties": [
"phase",
"dic"
],
"notes": "The facility DMRE getting-started record labels this installed 506014 objective as Ph3, but independent exact-code listings identify 506014 as Ph2, and facility staff confirmed Ph2 on 28 September 2026. The getting-started record is in error on this point. Working distance remains unknown."
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-leica-dmre--40x_air (catalogue ID, not a physical asset tag).
Leica · Objective
PL APO 63x/1.32 OIL PH3
Installed - as recorded
Leica DM RE
Product code: 506082
Recorded note: Working distance is 0.07 mm; 0.17 mm is the cover-glass specification and must not be used as WD.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 63x
- Numerical aperture (NA)
- 1.32
- Immersion
- Oil
- Working distance (as recorded)
- 0.07 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 2nd floor, room 2076.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-leica-dmre; objective: 63x_oil
{
"id": "63x_oil",
"manufacturer": "Leica",
"model": "PL APO 63x/1.32 OIL PH3",
"product_code": "506082",
"magnification": 63.0,
"numerical_aperture": 1.32,
"working_distance": "0.07 mm",
"immersion": "oil",
"correction": "plan_apochromat",
"afc_compatible": false,
"is_installed": true,
"specialties": [
"phase",
"dic"
],
"notes": "Working distance is 0.07 mm; 0.17 mm is the cover-glass specification and must not be used as WD.",
"url": "https://www.bristol.ac.uk/media-library/sites/wolfson-bioimaging/documents/widefield-1%20tech%20specs.pdf"
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-leica-dmre--63x_oil (catalogue ID, not a physical asset tag).
Leica · Objective
PL FLUOTAR 100x/1.30 OIL PH3
Installed - as recorded
Leica DM RE
Product code: 506017
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 100x
- Numerical aperture (NA)
- 1.3
- Immersion
- Oil
- Working distance (as recorded)
- Not recorded
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 2nd floor, room 2076.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-leica-dmre; objective: 100x_oil
{
"id": "100x_oil",
"manufacturer": "Leica",
"model": "PL FLUOTAR 100x/1.30 OIL PH3",
"product_code": "506017",
"magnification": 100.0,
"numerical_aperture": 1.3,
"immersion": "oil",
"correction": "plan_fluorite",
"afc_compatible": false,
"is_installed": true,
"specialties": [
"phase",
"dic"
]
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-leica-dmre--100x_oil (catalogue ID, not a physical asset tag).
Leica Microsystems · Objective
HC PL APO 10x/0.40 CS2
Installed - as recorded
Leica STELLARIS 8 FALCON FLIM
Product code: 15506424
Recorded note: Installed objective listed in local quotation.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 10x
- Numerical aperture (NA)
- 0.4
- Immersion
- Air
- Working distance (as recorded)
- 2.56 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room 5149.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-leica-stellaris-8-falcon-flim-resonant; objective: obj_10x_air_0_40
{
"id": "obj_10x_air_0_40",
"manufacturer": "Leica Microsystems",
"model": "HC PL APO 10x/0.40 CS2",
"product_code": "15506424",
"magnification": 10.0,
"numerical_aperture": 0.4,
"working_distance": "2.56 mm",
"immersion": "air",
"correction": "apochromat",
"afc_compatible": true,
"is_installed": true,
"notes": "Installed objective listed in local quotation."
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-leica-stellaris-8-falcon-flim-resonant--obj_10x_air_0_40 (catalogue ID, not a physical asset tag).
Leica Microsystems · Objective
HC PL APO 20x/0.75 CS2
Installed - as recorded
Leica STELLARIS 8 FALCON FLIM
Product code: 15506517
Recorded note: Installed objective listed in local quotation.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 20x
- Numerical aperture (NA)
- 0.75
- Immersion
- Air
- Working distance (as recorded)
- 0.62 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room 5149.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-leica-stellaris-8-falcon-flim-resonant; objective: obj_20x_air_0_75
{
"id": "obj_20x_air_0_75",
"manufacturer": "Leica Microsystems",
"model": "HC PL APO 20x/0.75 CS2",
"product_code": "15506517",
"magnification": 20.0,
"numerical_aperture": 0.75,
"working_distance": "0.62 mm",
"immersion": "air",
"correction": "apochromat",
"afc_compatible": true,
"is_installed": true,
"notes": "Installed objective listed in local quotation."
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-leica-stellaris-8-falcon-flim-resonant--obj_20x_air_0_75 (catalogue ID, not a physical asset tag).
Leica Microsystems · Objective
HC PL APO 40x/1.25 GLYC CORR CS2
Installed - as recorded
Leica STELLARIS 8 FALCON FLIM
Product code: 15506422
Recorded note: Installed objective listed in local quotation. Uses Type G immersion liquid, product code 15513910.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 40x
- Numerical aperture (NA)
- 1.25
- Immersion
- Glycerol
- Working distance (as recorded)
- 0.35 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room 5149.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-leica-stellaris-8-falcon-flim-resonant; objective: obj_40x_glycerol_1_25_corr
{
"id": "obj_40x_glycerol_1_25_corr",
"manufacturer": "Leica Microsystems",
"model": "HC PL APO 40x/1.25 GLYC CORR CS2",
"product_code": "15506422",
"magnification": 40.0,
"numerical_aperture": 1.25,
"working_distance": "0.35 mm",
"immersion": "glycerol",
"correction": "apochromat",
"afc_compatible": true,
"is_installed": true,
"specialties": [
"correction_collar"
],
"notes": "Installed objective listed in local quotation. Uses Type G immersion liquid, product code 15513910."
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-leica-stellaris-8-falcon-flim-resonant--obj_40x_glycerol_1_25_corr (catalogue ID, not a physical asset tag).
Leica Microsystems · Objective
HC PL APO 63x/1.40 OIL CS2
Installed - as recorded
Leica STELLARIS 8 FALCON FLIM
Product code: 15506350
Recorded note: Installed objective listed in local quotation. Uses Type F immersion liquid, ISO 8036, product code 15513859.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 63x
- Numerical aperture (NA)
- 1.4
- Immersion
- Oil
- Working distance (as recorded)
- 0.14 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room 5149.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-leica-stellaris-8-falcon-flim-resonant; objective: obj_63x_oil_1_40
{
"id": "obj_63x_oil_1_40",
"manufacturer": "Leica Microsystems",
"model": "HC PL APO 63x/1.40 OIL CS2",
"product_code": "15506350",
"magnification": 63.0,
"numerical_aperture": 1.4,
"working_distance": "0.14 mm",
"immersion": "oil",
"correction": "apochromat",
"afc_compatible": true,
"is_installed": true,
"notes": "Installed objective listed in local quotation. Uses Type F immersion liquid, ISO 8036, product code 15513859."
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-leica-stellaris-8-falcon-flim-resonant--obj_63x_oil_1_40 (catalogue ID, not a physical asset tag).
Leica Microsystems · Objective
HC PL APO 86x/1.20 W motCORR STED W
Installed - as recorded
Leica STELLARIS 8 FALCON FLIM
Product code: 15506333
Recorded note: Installed water objective listed in local quotation. Associated motCORR board product code 15525212 and water immersion micro dispenser product code 15640019. Included because it is installed, even though this instrument record does not currently declare a STED modality.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 86x
- Numerical aperture (NA)
- 1.2
- Immersion
- Water
- Working distance (as recorded)
- 0.3 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room 5149.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-leica-stellaris-8-falcon-flim-resonant; objective: obj_86x_water_1_20_motcorr_sted
{
"id": "obj_86x_water_1_20_motcorr_sted",
"manufacturer": "Leica Microsystems",
"model": "HC PL APO 86x/1.20 W motCORR STED W",
"product_code": "15506333",
"magnification": 86.0,
"numerical_aperture": 1.2,
"working_distance": "0.3 mm",
"immersion": "water",
"correction": "apochromat",
"afc_compatible": true,
"is_installed": true,
"specialties": [
"correction_collar",
"sted"
],
"notes": "Installed water objective listed in local quotation. Associated motCORR board product code 15525212 and water immersion micro dispenser product code 15640019. Included because it is installed, even though this instrument record does not currently declare a STED modality."
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-leica-stellaris-8-falcon-flim-resonant--obj_86x_water_1_20_motcorr_sted (catalogue ID, not a physical asset tag).
Leica · Objective
HCX APO L
Historical record: Installed - as recorded
Leica TCS SP5 Multiphoton
Product code: Not recorded
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 20x
- Numerical aperture (NA)
- 1.0
- Immersion
- Water
- Working distance (as recorded)
- 1.95 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Historical instrument location: Not recorded.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-leica-tcs-sp5-multiphoton; objective: 20x_water
{
"id": "20x_water",
"manufacturer": "Leica",
"model": "HCX APO L",
"magnification": 20.0,
"numerical_aperture": 1.0,
"working_distance": "1.95 mm",
"immersion": "water",
"correction": "apochromat",
"afc_compatible": false,
"is_installed": true
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-leica-tcs-sp5-multiphoton--20x_water (catalogue ID, not a physical asset tag).
Leica · Objective
HCX IR APO L
Historical record: Installed - as recorded
Leica TCS SP5 Multiphoton
Product code: Not recorded
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 25x
- Numerical aperture (NA)
- 0.95
- Immersion
- Water
- Working distance (as recorded)
- 2.50 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Historical instrument location: Not recorded.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-leica-tcs-sp5-multiphoton; objective: 25x_water
{
"id": "25x_water",
"manufacturer": "Leica",
"model": "HCX IR APO L",
"magnification": 25.0,
"numerical_aperture": 0.95,
"working_distance": "2.50 mm",
"immersion": "water",
"correction": "apochromat",
"afc_compatible": false,
"is_installed": true
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-leica-tcs-sp5-multiphoton--25x_water (catalogue ID, not a physical asset tag).
Leica · Objective
N PLAN 5x/0.12 PH 0
Installed - as recorded
Leica Thunder
Product code: 11506303
Recorded note: FN 22
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 5x
- Numerical aperture (NA)
- 0.12
- Immersion
- Air
- Working distance (as recorded)
- 14.0 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room Dunkel.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-leica-thunder; objective: 5x_air
{
"id": "5x_air",
"manufacturer": "Leica",
"model": "N PLAN 5x/0.12 PH 0",
"product_code": "11506303",
"magnification": 5.0,
"numerical_aperture": 0.12,
"working_distance": "14.0 mm",
"immersion": "air",
"correction": "plan_achromat",
"afc_compatible": false,
"is_installed": true,
"specialties": [
"phase",
"dic",
"uv_transmission"
],
"notes": "FN 22",
"url": "https://www.leica-microsystems.com/objectivefinder/detail/objective/506303/"
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-leica-thunder--5x_air (catalogue ID, not a physical asset tag).
Leica · Objective
HC PL APO 10x/0.45
Installed - as recorded
Leica Thunder
Product code: 11506410
Recorded note: FN 25
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 10x
- Numerical aperture (NA)
- 0.45
- Immersion
- Air
- Working distance (as recorded)
- 2.8 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room Dunkel.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-leica-thunder; objective: 10x_air
{
"id": "10x_air",
"manufacturer": "Leica",
"model": "HC PL APO 10x/0.45",
"product_code": "11506410",
"magnification": 10.0,
"numerical_aperture": 0.45,
"working_distance": "2.8 mm",
"immersion": "air",
"correction": "plan_apochromat",
"afc_compatible": true,
"is_installed": true,
"specialties": [
"dic",
"uv_transmission"
],
"notes": "FN 25",
"url": "https://www.leica-microsystems.com/objectivefinder/detail/objective/506410/"
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-leica-thunder--10x_air (catalogue ID, not a physical asset tag).
Leica · Objective
HC PL FLUOTAR L 20x/0.40 CORR
Installed - as recorded
Leica Thunder
Product code: 11506242
Recorded note: FN 25
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 20x
- Numerical aperture (NA)
- 0.4
- Immersion
- Air
- Working distance (as recorded)
- 7.5 - 6.2 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room Dunkel.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-leica-thunder; objective: 20x_air
{
"id": "20x_air",
"manufacturer": "Leica",
"model": "HC PL FLUOTAR L 20x/0.40 CORR",
"product_code": "11506242",
"magnification": 20.0,
"numerical_aperture": 0.4,
"working_distance": "7.5 - 6.2 mm",
"immersion": "air",
"correction": "fluorite",
"afc_compatible": true,
"is_installed": true,
"specialties": [
"correction_collar",
"dic",
"uv_transmission"
],
"notes": "FN 25",
"url": "https://www.leica-microsystems.com/objectivefinder/detail/objective/506242/"
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-leica-thunder--20x_air (catalogue ID, not a physical asset tag).
Leica · Objective
HC PL APO 20x/0.70 IMM CORR
Installed - as recorded
Leica Thunder
Product code: 11506326
Recorded note: FN 25; W/O/G Immersion
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 20x
- Numerical aperture (NA)
- 0.7
- Immersion
- Multi-Immersion
- Working distance (as recorded)
- 0.66 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room Dunkel.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-leica-thunder; objective: 20x_multi
{
"id": "20x_multi",
"manufacturer": "Leica",
"model": "HC PL APO 20x/0.70 IMM CORR",
"product_code": "11506326",
"magnification": 20.0,
"numerical_aperture": 0.7,
"working_distance": "0.66 mm",
"immersion": "multi",
"correction": "plan_apochromat",
"afc_compatible": false,
"is_installed": true,
"specialties": [
"correction_collar",
"dic",
"uv_transmission"
],
"notes": "FN 25; W/O/G Immersion",
"url": "https://www.leica-microsystems.com/objectivefinder/detail/objective/506326/"
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-leica-thunder--20x_multi (catalogue ID, not a physical asset tag).
Leica · Objective
HC PL APO 20x/0.80
Installed - as recorded
Leica Thunder
Product code: 11506529
Recorded note: FN 25
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 20x
- Numerical aperture (NA)
- 0.8
- Immersion
- Air
- Working distance (as recorded)
- 0.4 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room Dunkel.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-leica-thunder; objective: 20x_air_2
{
"id": "20x_air_2",
"manufacturer": "Leica",
"model": "HC PL APO 20x/0.80",
"product_code": "11506529",
"magnification": 20.0,
"numerical_aperture": 0.8,
"working_distance": "0.4 mm",
"immersion": "air",
"correction": "plan_apochromat",
"afc_compatible": true,
"is_installed": true,
"specialties": [
"dic",
"uv_transmission"
],
"notes": "FN 25",
"url": "https://www.leica-microsystems.com/objectivefinder/detail/objective/506529/"
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-leica-thunder--20x_air_2 (catalogue ID, not a physical asset tag).
Leica · Objective
HC PL APO 63x/1.40 OIL CS2
Installed - as recorded
Leica Thunder
Product code: 11506350
Recorded note: FN 25
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 63x
- Numerical aperture (NA)
- 1.4
- Immersion
- Oil
- Working distance (as recorded)
- 0.14 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room Dunkel.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-leica-thunder; objective: 63x_oil
{
"id": "63x_oil",
"manufacturer": "Leica",
"model": "HC PL APO 63x/1.40 OIL CS2",
"product_code": "11506350",
"magnification": 63.0,
"numerical_aperture": 1.4,
"working_distance": "0.14 mm",
"immersion": "oil",
"correction": "plan_apochromat",
"afc_compatible": true,
"is_installed": true,
"specialties": [
"dic",
"uv_transmission"
],
"notes": "FN 25",
"url": "https://www.leica-microsystems.com/objectivefinder/detail/objective/506350/"
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-leica-thunder--63x_oil (catalogue ID, not a physical asset tag).
Leica · Objective
HC FLUOTAR L 16x/0.60 IMM CORR VISIR
Associated - not installed
Leica Thunder
Product code: 506533
Recorded note: FN 20
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 16x
- Numerical aperture (NA)
- 0.6
- Immersion
- Multi-Immersion
- Working distance (as recorded)
- 2.5 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room Dunkel.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-leica-thunder; objective: 16x_multi
{
"id": "16x_multi",
"manufacturer": "Leica",
"model": "HC FLUOTAR L 16x/0.60 IMM CORR VISIR",
"product_code": "506533",
"magnification": 16.0,
"numerical_aperture": 0.6,
"working_distance": "2.5 mm",
"immersion": "multi",
"correction": "fluorite",
"afc_compatible": true,
"is_installed": false,
"specialties": [
"correction_collar",
"ir_transmission",
"dic"
],
"notes": "FN 20",
"url": "https://www.leica-microsystems.com/objectivefinder/detail/objective/506533/"
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-leica-thunder--16x_multi (catalogue ID, not a physical asset tag).
Leica · Objective
HC PL APO FLUOTAR 10x/0.30 PH 1
Associated - not installed
Leica Thunder
Product code: 11506507
Recorded note: FN 25; from SP5?
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 10x
- Numerical aperture (NA)
- 0.3
- Immersion
- Air
- Working distance (as recorded)
- 11.0 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room Dunkel.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-leica-thunder; objective: 10x_air_2
{
"id": "10x_air_2",
"manufacturer": "Leica",
"model": "HC PL APO FLUOTAR 10x/0.30 PH 1",
"product_code": "11506507",
"magnification": 10.0,
"numerical_aperture": 0.3,
"working_distance": "11.0 mm",
"immersion": "air",
"correction": "plan_apochromat",
"afc_compatible": false,
"is_installed": false,
"specialties": [
"phase",
"dic",
"uv_transmission"
],
"notes": "FN 25; from SP5?",
"url": "https://www.leica-microsystems.com/objectivefinder/detail/objective/506507/"
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-leica-thunder--10x_air_2 (catalogue ID, not a physical asset tag).
Leica · Objective
HC PL APO 100x/1.40 OIL STED
Associated - not installed
Leica Thunder
Product code: 11506316
Recorded note: FN 25; from SP5?
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 100x
- Numerical aperture (NA)
- 1.4
- Immersion
- Oil
- Working distance (as recorded)
- 0.13 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room Dunkel.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-leica-thunder; objective: 100x_oil
{
"id": "100x_oil",
"manufacturer": "Leica",
"model": "HC PL APO 100x/1.40 OIL STED",
"product_code": "11506316",
"magnification": 100.0,
"numerical_aperture": 1.4,
"working_distance": "0.13 mm",
"immersion": "oil",
"correction": "plan_apochromat",
"afc_compatible": false,
"is_installed": false,
"specialties": [
"sted",
"dic",
"uv_transmission"
],
"notes": "FN 25; from SP5?",
"url": "https://www.leica-microsystems.com/objectivefinder/detail/objective/506316/"
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-leica-thunder--100x_oil (catalogue ID, not a physical asset tag).
Special Optics · Objective
54-10-12 Airy beam dipping objective
Installed - as recorded
MSquared Aurora Airy Beam
Product code: 54-10-12
Recorded note: Excitation and detection objectives designed for dipping media with refractive index range 1.33-1.56 (NA 0.37-0.43), magnification range 15.3x-17.9x across RI. FOV 1.2 mm diameter.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 17x
- Numerical aperture (NA)
- 0.4
- Immersion
- Multi-Immersion
- Working distance (as recorded)
- 12 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room 5149.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-msquared-aurora-airy-beam; objective: 17x_multi
{
"id": "17x_multi",
"manufacturer": "Special Optics",
"model": "54-10-12 Airy beam dipping objective",
"product_code": "54-10-12",
"magnification": 17.0,
"numerical_aperture": 0.4,
"working_distance": "12 mm",
"immersion": "multi",
"correction": "fluorite",
"afc_compatible": false,
"is_installed": true,
"specialties": [
"cleared_tissue_imaging"
],
"notes": "Excitation and detection objectives designed for dipping media with refractive index range 1.33-1.56 (NA 0.37-0.43), magnification range 15.3x-17.9x across RI. FOV 1.2 mm diameter."
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-msquared-aurora-airy-beam--17x_multi (catalogue ID, not a physical asset tag).
Nikon · Objective
Plan UW 2x/0.06
Installed - as recorded
Nikon Eclipse Ti2-E
Product code: MRL00022
Recorded note: Mode suitability: BF recommended; FLUO (VIS) possible; polarization possible.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 2x
- Numerical aperture (NA)
- 0.06
- Immersion
- Air
- Working distance (as recorded)
- 7.5 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room Dunkel.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-nikon-eclipse-ti2-e; objective: 2x_air
{
"id": "2x_air",
"manufacturer": "Nikon",
"model": "Plan UW 2x/0.06",
"product_code": "MRL00022",
"magnification": 2.0,
"numerical_aperture": 0.06,
"working_distance": "7.5 mm",
"immersion": "air",
"correction": "plan_achromat",
"afc_compatible": false,
"is_installed": true,
"specialties": [
"polarization"
],
"notes": "Mode suitability: BF recommended; FLUO (VIS) possible; polarization possible."
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-nikon-eclipse-ti2-e--2x_air (catalogue ID, not a physical asset tag).
Nikon · Objective
Plan Fluor 4x/0.13
Installed - as recorded
Nikon Eclipse Ti2-E
Product code: MRH00041
Recorded note: Mode suitability: BF recommended; FLUO (VIS) recommended; FLUO (UV) recommended; polarization possible.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 4x
- Numerical aperture (NA)
- 0.13
- Immersion
- Air
- Working distance (as recorded)
- 17.2 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room Dunkel.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-nikon-eclipse-ti2-e; objective: 4x_air
{
"id": "4x_air",
"manufacturer": "Nikon",
"model": "Plan Fluor 4x/0.13",
"product_code": "MRH00041",
"magnification": 4.0,
"numerical_aperture": 0.13,
"working_distance": "17.2 mm",
"immersion": "air",
"correction": "plan_fluorite",
"afc_compatible": false,
"is_installed": true,
"specialties": [
"polarization"
],
"notes": "Mode suitability: BF recommended; FLUO (VIS) recommended; FLUO (UV) recommended; polarization possible."
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-nikon-eclipse-ti2-e--4x_air (catalogue ID, not a physical asset tag).
Nikon · Objective
Plan Apo λD 4x/0.20
Installed - as recorded
Nikon Eclipse Ti2-E
Product code: MRD70040
Recorded note: Optical family: Lambda D. Mode suitability: BF recommended; FLUO (VIS) recommended; FLUO (NIR) recommended.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 4x
- Numerical aperture (NA)
- 0.2
- Immersion
- Air
- Working distance (as recorded)
- 20.0 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room Dunkel.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-nikon-eclipse-ti2-e; objective: 4x_air_2
{
"id": "4x_air_2",
"manufacturer": "Nikon",
"model": "Plan Apo λD 4x/0.20",
"product_code": "MRD70040",
"magnification": 4.0,
"numerical_aperture": 0.2,
"working_distance": "20.0 mm",
"immersion": "air",
"correction": "plan_apochromat",
"afc_compatible": false,
"is_installed": true,
"notes": "Optical family: Lambda D. Mode suitability: BF recommended; FLUO (VIS) recommended; FLUO (NIR) recommended."
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-nikon-eclipse-ti2-e--4x_air_2 (catalogue ID, not a physical asset tag).
Nikon · Objective
Plan Fluor 10x/0.30 OFN 25 Ph1 DL
Installed - as recorded
Nikon Eclipse Ti2-E
Product code: MRH20101
Recorded note: OFN 25. Mode suitability: BF suitable; FLUO (VIS) suitable; FLUO (UV) suitable.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 10x
- Numerical aperture (NA)
- 0.3
- Immersion
- Air
- Working distance (as recorded)
- 15.2 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room Dunkel.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-nikon-eclipse-ti2-e; objective: 10x_air
{
"id": "10x_air",
"manufacturer": "Nikon",
"model": "Plan Fluor 10x/0.30 OFN 25 Ph1 DL",
"product_code": "MRH20101",
"magnification": 10.0,
"numerical_aperture": 0.3,
"working_distance": "15.2 mm",
"immersion": "air",
"correction": "plan_fluorite",
"afc_compatible": true,
"is_installed": true,
"specialties": [
"phase"
],
"notes": "OFN 25. Mode suitability: BF suitable; FLUO (VIS) suitable; FLUO (UV) suitable."
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-nikon-eclipse-ti2-e--10x_air (catalogue ID, not a physical asset tag).
Nikon · Objective
S Plan Fluor ELWD ADM 20x/0.45 DIC N1
Installed - as recorded
Nikon Eclipse Ti2-E
Product code: MRH08230
Recorded note: Mode suitability: BF recommended; FLUO (VIS) recommended; FLUO (UV) recommended; polarization suitable.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 20x
- Numerical aperture (NA)
- 0.45
- Immersion
- Air
- Working distance (as recorded)
- 8.2 - 6.9 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room Dunkel.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-nikon-eclipse-ti2-e; objective: 20x_air
{
"id": "20x_air",
"manufacturer": "Nikon",
"model": "S Plan Fluor ELWD ADM 20x/0.45 DIC N1",
"product_code": "MRH08230",
"magnification": 20.0,
"numerical_aperture": 0.45,
"working_distance": "8.2 - 6.9 mm",
"immersion": "air",
"correction": "plan_fluorite",
"afc_compatible": true,
"is_installed": true,
"specialties": [
"long_working_distance",
"dic",
"polarization"
],
"notes": "Mode suitability: BF recommended; FLUO (VIS) recommended; FLUO (UV) recommended; polarization suitable."
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-nikon-eclipse-ti2-e--20x_air (catalogue ID, not a physical asset tag).
Nikon · Objective
Plan Apo λ 20x/0.75 OFN25 DIC N2
Installed - as recorded
Nikon Eclipse Ti2-E
Product code: MRD00205
Recorded note: OFN 25. Optical family: Lambda. Mode suitability: BF recommended; FLUO (VIS) recommended; FLUO (UV) recommended; polarization possible.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 20x
- Numerical aperture (NA)
- 0.75
- Immersion
- Air
- Working distance (as recorded)
- 1.0 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room Dunkel.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-nikon-eclipse-ti2-e; objective: 20x_air_2
{
"id": "20x_air_2",
"manufacturer": "Nikon",
"model": "Plan Apo λ 20x/0.75 OFN25 DIC N2",
"product_code": "MRD00205",
"magnification": 20.0,
"numerical_aperture": 0.75,
"working_distance": "1.0 mm",
"immersion": "air",
"correction": "plan_apochromat",
"afc_compatible": true,
"is_installed": true,
"specialties": [
"dic",
"polarization"
],
"notes": "OFN 25. Optical family: Lambda. Mode suitability: BF recommended; FLUO (VIS) recommended; FLUO (UV) recommended; polarization possible."
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-nikon-eclipse-ti2-e--20x_air_2 (catalogue ID, not a physical asset tag).
Nikon · Objective
S Plan Fluor ELWD 40x/0.60 OFN22 Ph2
Installed - as recorded
Nikon Eclipse Ti2-E
Product code: MRH48430
Recorded note: OFN 22. Mode suitability: BF suitable; FLUO (VIS) suitable; FLUO (UV) suitable.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 40x
- Numerical aperture (NA)
- 0.6
- Immersion
- Air
- Working distance (as recorded)
- 3.6 - 2.8 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room Dunkel.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-nikon-eclipse-ti2-e; objective: 40x_air
{
"id": "40x_air",
"manufacturer": "Nikon",
"model": "S Plan Fluor ELWD 40x/0.60 OFN22 Ph2",
"product_code": "MRH48430",
"magnification": 40.0,
"numerical_aperture": 0.6,
"working_distance": "3.6 - 2.8 mm",
"immersion": "air",
"correction": "plan_fluorite",
"afc_compatible": true,
"is_installed": true,
"specialties": [
"long_working_distance",
"phase"
],
"notes": "OFN 22. Mode suitability: BF suitable; FLUO (VIS) suitable; FLUO (UV) suitable."
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-nikon-eclipse-ti2-e--40x_air (catalogue ID, not a physical asset tag).
Nikon · Objective
Plan Apo λ 60x/1.40 Oil OFN25 DIC N2
Installed - as recorded
Nikon Eclipse Ti2-E
Product code: MRD01605
Recorded note: OFN 25. Optical family: Lambda. Mode suitability: BF recommended; FLUO (VIS) recommended; FLUO (NIR) recommended; polarization suitable.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 60x
- Numerical aperture (NA)
- 1.4
- Immersion
- Oil
- Working distance (as recorded)
- 0.13 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room Dunkel.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-nikon-eclipse-ti2-e; objective: 60x_oil
{
"id": "60x_oil",
"manufacturer": "Nikon",
"model": "Plan Apo λ 60x/1.40 Oil OFN25 DIC N2",
"product_code": "MRD01605",
"magnification": 60.0,
"numerical_aperture": 1.4,
"working_distance": "0.13 mm",
"immersion": "oil",
"correction": "plan_apochromat",
"afc_compatible": true,
"is_installed": true,
"specialties": [
"dic",
"polarization"
],
"notes": "OFN 25. Optical family: Lambda. Mode suitability: BF recommended; FLUO (VIS) recommended; FLUO (NIR) recommended; polarization suitable."
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-nikon-eclipse-ti2-e--60x_oil (catalogue ID, not a physical asset tag).
Nikon · Objective
Apo TIRF 100x/1.49 Oil
Installed - as recorded
Nikon Eclipse Ti2-E
Product code: MRD01991
Recorded note: Mode suitability: BF recommended; FLUO (VIS) recommended; FLUO (UV) possible; polarization suitable.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 100x
- Numerical aperture (NA)
- 1.49
- Immersion
- Oil
- Working distance (as recorded)
- 0.16 - 0.10 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room Dunkel.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-nikon-eclipse-ti2-e; objective: 100x_oil
{
"id": "100x_oil",
"manufacturer": "Nikon",
"model": "Apo TIRF 100x/1.49 Oil",
"product_code": "MRD01991",
"magnification": 100.0,
"numerical_aperture": 1.49,
"working_distance": "0.16 - 0.10 mm",
"immersion": "oil",
"correction": "apochromat",
"afc_compatible": true,
"is_installed": true,
"specialties": [
"tirf",
"phase",
"dic",
"polarization"
],
"notes": "Mode suitability: BF recommended; FLUO (VIS) recommended; FLUO (UV) possible; polarization suitable."
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-nikon-eclipse-ti2-e--100x_oil (catalogue ID, not a physical asset tag).
Nikon · Objective
CFI Plan Apochromat Lambda D 4X
Installed - as recorded
Nikon Ti2-E Crest V3
Product code: MRD70040
Recorded note: Optical family: Lambda D. FOV 25.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 4x
- Numerical aperture (NA)
- 0.2
- Immersion
- Air
- Working distance (as recorded)
- 20.0 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room 5149.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-nikon-crest-v3; objective: 4x_air
{
"id": "4x_air",
"manufacturer": "Nikon",
"model": "CFI Plan Apochromat Lambda D 4X",
"product_code": "MRD70040",
"magnification": 4.0,
"numerical_aperture": 0.2,
"working_distance": "20.0 mm",
"immersion": "air",
"correction": "plan_apochromat",
"afc_compatible": false,
"is_installed": true,
"notes": "Optical family: Lambda D. FOV 25."
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-nikon-crest-v3--4x_air (catalogue ID, not a physical asset tag).
Nikon · Objective
CFI Plan Apochromat Lambda D 20X DIC N2
Installed - as recorded
Nikon Ti2-E Crest V3
Product code: MRD70270
Recorded note: Optical family: Lambda D. FOV 25. Requires DIC-prism N2.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 20x
- Numerical aperture (NA)
- 0.8
- Immersion
- Air
- Working distance (as recorded)
- 0.8 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room 5149.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-nikon-crest-v3; objective: 20x_air
{
"id": "20x_air",
"manufacturer": "Nikon",
"model": "CFI Plan Apochromat Lambda D 20X DIC N2",
"product_code": "MRD70270",
"magnification": 20.0,
"numerical_aperture": 0.8,
"working_distance": "0.8 mm",
"immersion": "air",
"correction": "plan_apochromat",
"afc_compatible": true,
"is_installed": true,
"specialties": [
"dic"
],
"notes": "Optical family: Lambda D. FOV 25. Requires DIC-prism N2."
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-nikon-crest-v3--20x_air (catalogue ID, not a physical asset tag).
Nikon · Objective
CFI Plan Apochromat Lambda S 25XC Sil DIC N2
Installed - as recorded
Nikon Ti2-E Crest V3
Product code: MRD73250
Recorded note: Optical family: Lambda S. Requires DIC-prism N2.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 25x
- Numerical aperture (NA)
- 1.05
- Immersion
- Silicone
- Working distance (as recorded)
- 0.55 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room 5149.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-nikon-crest-v3; objective: 25x_silicone
{
"id": "25x_silicone",
"manufacturer": "Nikon",
"model": "CFI Plan Apochromat Lambda S 25XC Sil DIC N2",
"product_code": "MRD73250",
"magnification": 25.0,
"numerical_aperture": 1.05,
"working_distance": "0.55 mm",
"immersion": "silicone",
"correction": "plan_apochromat",
"afc_compatible": true,
"is_installed": true,
"specialties": [
"dic"
],
"notes": "Optical family: Lambda S. Requires DIC-prism N2."
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-nikon-crest-v3--25x_silicone (catalogue ID, not a physical asset tag).
Nikon · Objective
CFI Apochromat LWD Lambda S 40XC WI DIC N2
Installed - as recorded
Nikon Ti2-E Crest V3
Product code: MRD77410
Recorded note: Optical family: Lambda S. Chromatic correction: 405-950nm. Requires DIC-prism N2.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 40x
- Numerical aperture (NA)
- 1.15
- Immersion
- Water
- Working distance (as recorded)
- 0.60 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room 5149.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-nikon-crest-v3; objective: 40x_water
{
"id": "40x_water",
"manufacturer": "Nikon",
"model": "CFI Apochromat LWD Lambda S 40XC WI DIC N2",
"product_code": "MRD77410",
"magnification": 40.0,
"numerical_aperture": 1.15,
"working_distance": "0.60 mm",
"immersion": "water",
"correction": "apochromat",
"afc_compatible": true,
"is_installed": true,
"specialties": [
"long_working_distance",
"dic"
],
"notes": "Optical family: Lambda S. Chromatic correction: 405-950nm. Requires DIC-prism N2."
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-nikon-crest-v3--40x_water (catalogue ID, not a physical asset tag).
Nikon · Objective
CFI Plan Apochromat Lambda S 60XC Sil DIC N2
Installed - as recorded
Nikon Ti2-E Crest V3
Product code: MRD73600
Recorded note: Optical family: Lambda S. Requires DIC-prism N2.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 60x
- Numerical aperture (NA)
- 1.3
- Immersion
- Silicone
- Working distance (as recorded)
- 0.30 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room 5149.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-nikon-crest-v3; objective: 60x_silicone
{
"id": "60x_silicone",
"manufacturer": "Nikon",
"model": "CFI Plan Apochromat Lambda S 60XC Sil DIC N2",
"product_code": "MRD73600",
"magnification": 60.0,
"numerical_aperture": 1.3,
"working_distance": "0.30 mm",
"immersion": "silicone",
"correction": "plan_apochromat",
"afc_compatible": true,
"is_installed": true,
"specialties": [
"dic"
],
"notes": "Optical family: Lambda S. Requires DIC-prism N2."
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-nikon-crest-v3--60x_silicone (catalogue ID, not a physical asset tag).
Nikon · Objective
CFI Plan Apochromat Lambda D 100x Oil
Installed - as recorded
Nikon Ti2-E Crest V3
Product code: MRD71970
Recorded note: Optical family: Lambda D. FOV 25.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 100x
- Numerical aperture (NA)
- 1.45
- Immersion
- Oil
- Working distance (as recorded)
- 0.13 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room 5149.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-nikon-crest-v3; objective: 100x_oil
{
"id": "100x_oil",
"manufacturer": "Nikon",
"model": "CFI Plan Apochromat Lambda D 100x Oil",
"product_code": "MRD71970",
"magnification": 100.0,
"numerical_aperture": 1.45,
"working_distance": "0.13 mm",
"immersion": "oil",
"correction": "plan_apochromat",
"afc_compatible": true,
"is_installed": true,
"notes": "Optical family: Lambda D. FOV 25."
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-nikon-crest-v3--100x_oil (catalogue ID, not a physical asset tag).
Nikon · Objective
Apo TIRF 100x/1.49 Oil DIC N2
Associated - not installed
Nikon Ti2-E Crest V3
Product code: MRD01991
Recorded note: Optional objective. Requires DIC-prism N2.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 100x
- Numerical aperture (NA)
- 1.49
- Immersion
- Oil
- Working distance (as recorded)
- 0.13 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room 5149.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-nikon-crest-v3; objective: 100x_oil_tirf
{
"id": "100x_oil_tirf",
"manufacturer": "Nikon",
"model": "Apo TIRF 100x/1.49 Oil DIC N2",
"product_code": "MRD01991",
"magnification": 100.0,
"numerical_aperture": 1.49,
"working_distance": "0.13 mm",
"immersion": "oil",
"correction": "apochromat",
"afc_compatible": true,
"is_installed": false,
"specialties": [
"tirf",
"dic"
],
"notes": "Optional objective. Requires DIC-prism N2."
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-nikon-crest-v3--100x_oil_tirf (catalogue ID, not a physical asset tag).
Olympus · Objective
PlanC 4x/0.10
Installed - as recorded
Olympus BX60
Product code: Not recorded
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 4x
- Numerical aperture (NA)
- 0.1
- Immersion
- Air
- Working distance (as recorded)
- 18.5 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: MediCity, BioCity 4th floor, room 4086.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-olympus-bx60; objective: 4x_air
{
"id": "4x_air",
"manufacturer": "Olympus",
"model": "PlanC 4x/0.10",
"magnification": 4.0,
"numerical_aperture": 0.1,
"working_distance": "18.5 mm",
"immersion": "air",
"correction": "plan_achromat",
"afc_compatible": false,
"is_installed": true
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-olympus-bx60--4x_air (catalogue ID, not a physical asset tag).
Olympus · Objective
UPlanFl 10x/0.30 Ph1
Installed - as recorded
Olympus BX60
Product code: Not recorded
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 10x
- Numerical aperture (NA)
- 0.3
- Immersion
- Air
- Working distance (as recorded)
- 10.0 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: MediCity, BioCity 4th floor, room 4086.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-olympus-bx60; objective: 10x_air
{
"id": "10x_air",
"manufacturer": "Olympus",
"model": "UPlanFl 10x/0.30 Ph1",
"magnification": 10.0,
"numerical_aperture": 0.3,
"working_distance": "10.0 mm",
"immersion": "air",
"correction": "plan_fluorite",
"afc_compatible": false,
"is_installed": true,
"specialties": [
"phase"
]
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-olympus-bx60--10x_air (catalogue ID, not a physical asset tag).
Olympus · Objective
UPlanFl 20x/0.50 Ph1
Installed - as recorded
Olympus BX60
Product code: Not recorded
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 20x
- Numerical aperture (NA)
- 0.5
- Immersion
- Air
- Working distance (as recorded)
- 2.1 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: MediCity, BioCity 4th floor, room 4086.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-olympus-bx60; objective: 20x_air
{
"id": "20x_air",
"manufacturer": "Olympus",
"model": "UPlanFl 20x/0.50 Ph1",
"magnification": 20.0,
"numerical_aperture": 0.5,
"working_distance": "2.1 mm",
"immersion": "air",
"correction": "plan_fluorite",
"afc_compatible": false,
"is_installed": true,
"specialties": [
"phase"
]
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-olympus-bx60--20x_air (catalogue ID, not a physical asset tag).
Olympus · Objective
UPlanFl 40x/0.75 Ph2
Installed - as recorded
Olympus BX60
Product code: Not recorded
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 40x
- Numerical aperture (NA)
- 0.75
- Immersion
- Air
- Working distance (as recorded)
- 0.51 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: MediCity, BioCity 4th floor, room 4086.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-olympus-bx60; objective: 40x_air
{
"id": "40x_air",
"manufacturer": "Olympus",
"model": "UPlanFl 40x/0.75 Ph2",
"magnification": 40.0,
"numerical_aperture": 0.75,
"working_distance": "0.51 mm",
"immersion": "air",
"correction": "plan_fluorite",
"afc_compatible": false,
"is_installed": true,
"specialties": [
"phase"
]
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-olympus-bx60--40x_air (catalogue ID, not a physical asset tag).
Olympus · Objective
UPlanApo 100x/1.35 Oil Iris Ph3
Installed - as recorded
Olympus BX60
Product code: Not recorded
Recorded note: Includes adjustable iris
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 100x
- Numerical aperture (NA)
- 1.35
- Immersion
- Oil
- Working distance (as recorded)
- 0.17 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: MediCity, BioCity 4th floor, room 4086.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-olympus-bx60; objective: 100x_oil
{
"id": "100x_oil",
"manufacturer": "Olympus",
"model": "UPlanApo 100x/1.35 Oil Iris Ph3",
"magnification": 100.0,
"numerical_aperture": 1.35,
"working_distance": "0.17 mm",
"immersion": "oil",
"correction": "plan_apochromat",
"afc_compatible": false,
"is_installed": true,
"specialties": [
"phase"
],
"notes": "Includes adjustable iris"
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-olympus-bx60--100x_oil (catalogue ID, not a physical asset tag).
Olympus · Objective
UPlanFl 60x/1.25 Oil Iris Ph3
Associated - not installed
Olympus BX60
Product code: Not recorded
Recorded note: Optional objective. Includes adjustable iris. Working distance cross-checked against an exact UPlanFl 60x/1.25 Oil Iris Ph3 listing.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 60x
- Numerical aperture (NA)
- 1.25
- Immersion
- Oil
- Working distance (as recorded)
- 0.12 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: MediCity, BioCity 4th floor, room 4086.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-olympus-bx60; objective: 60x_oil
{
"id": "60x_oil",
"manufacturer": "Olympus",
"model": "UPlanFl 60x/1.25 Oil Iris Ph3",
"magnification": 60.0,
"numerical_aperture": 1.25,
"working_distance": "0.12 mm",
"immersion": "oil",
"correction": "plan_fluorite",
"afc_compatible": false,
"is_installed": false,
"specialties": [
"phase"
],
"notes": "Optional objective. Includes adjustable iris. Working distance cross-checked against an exact UPlanFl 60x/1.25 Oil Iris Ph3 listing.",
"url": "https://wie-tec.de/Olympus-microscope-objective-UPlanFl-60x-125-Oil-Iris-Ph3-UPLFLN60XOI"
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-olympus-bx60--60x_oil (catalogue ID, not a physical asset tag).
Olympus · Objective
UPLXAPO100XO
Installed - as recorded
ONI Nanoimager
Product code: Not recorded
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 100x
- Numerical aperture (NA)
- 1.45
- Immersion
- Oil
- Working distance (as recorded)
- 0.13 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: Turku Bioscience, BioCity, 5th floor, room 5149.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-oni-nanoimager; objective: 100x_oil
{
"id": "100x_oil",
"manufacturer": "Olympus",
"model": "UPLXAPO100XO",
"magnification": 100.0,
"numerical_aperture": 1.45,
"working_distance": "0.13 mm",
"immersion": "oil",
"correction": "apochromat",
"afc_compatible": true,
"is_installed": true
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-oni-nanoimager--100x_oil (catalogue ID, not a physical asset tag).
Zeiss · Objective
PlanApo Z
Installed - as recorded
Zeiss AxioZoom.V16
Product code: Not recorded
Recorded note: System magnification range 3.5x-56x. Field of view range 66-4 mm. ApoTome compatible: No.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 0.5x
- Numerical aperture (NA)
- 0.125
- Immersion
- Air
- Working distance (as recorded)
- 114 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room Dunkel.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-zeiss-axiozoom-v16; objective: 0.5x_air
{
"id": "0.5x_air",
"manufacturer": "Zeiss",
"model": "PlanApo Z",
"magnification": 0.5,
"numerical_aperture": 0.125,
"working_distance": "114 mm",
"immersion": "air",
"correction": "plan_apochromat",
"afc_compatible": false,
"is_installed": true,
"notes": "System magnification range 3.5x-56x. Field of view range 66-4 mm. ApoTome compatible: No."
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-zeiss-axiozoom-v16--0.5x_air (catalogue ID, not a physical asset tag).
Zeiss · Objective
PlanApo Z
Installed - as recorded
Zeiss AxioZoom.V16
Product code: Not recorded
Recorded note: System magnification range 7x-112x. Field of view range 33-2 mm. ApoTome compatible from 40x-112x.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 1x
- Numerical aperture (NA)
- 0.125
- Immersion
- Air
- Working distance (as recorded)
- 56 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room Dunkel.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-zeiss-axiozoom-v16; objective: 1x_air
{
"id": "1x_air",
"manufacturer": "Zeiss",
"model": "PlanApo Z",
"magnification": 1.0,
"numerical_aperture": 0.125,
"working_distance": "56 mm",
"immersion": "air",
"correction": "plan_apochromat",
"afc_compatible": false,
"is_installed": true,
"notes": "System magnification range 7x-112x. Field of view range 33-2 mm. ApoTome compatible from 40x-112x."
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-zeiss-axiozoom-v16--1x_air (catalogue ID, not a physical asset tag).
Unknown · Objective
Placeholder
Installed - as recorded
Zeiss LSM 510 JPK AFM
Product code: Not recorded
Recorded note: Placeholder objective.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 10x
- Numerical aperture (NA)
- 0.3
- Immersion
- Air
- Working distance (as recorded)
- Not recorded
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, floor -1 (Basement).
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-zeiss-lsm-510-jpk-afm; objective: placeholder_objective
{
"id": "placeholder_objective",
"manufacturer": "Unknown",
"model": "Placeholder",
"magnification": 10.0,
"numerical_aperture": 0.3,
"immersion": "air",
"correction": "plan_achromat",
"afc_compatible": false,
"is_installed": true,
"notes": "Placeholder objective."
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-zeiss-lsm-510-jpk-afm--placeholder_objective (catalogue ID, not a physical asset tag).
Zeiss · Objective
Plan-APOCHROMAT 10x/0.3
Installed - as recorded
Zeiss LSM 880 with AiryScan
Product code: 420640-9800
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 10x
- Numerical aperture (NA)
- 0.3
- Immersion
- Air
- Working distance (as recorded)
- 2.0 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room 5149.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-zeiss-lsm-880-with-airyscan; objective: 10x_air
{
"id": "10x_air",
"manufacturer": "Zeiss",
"model": "Plan-APOCHROMAT 10x/0.3",
"product_code": "420640-9800",
"magnification": 10.0,
"numerical_aperture": 0.3,
"working_distance": "2.0 mm",
"immersion": "air",
"correction": "plan_apochromat",
"afc_compatible": false,
"is_installed": true,
"url": "https://www.micro-shop.zeiss.com/en/us/shop/objectives/420640-9800-000/Objective-Plan-Apochromat-10x-0.3-M27"
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-zeiss-lsm-880-with-airyscan--10x_air (catalogue ID, not a physical asset tag).
Zeiss · Objective
Plan-APOCHROMAT 20x/0.8
Installed - as recorded
Zeiss LSM 880 with AiryScan
Product code: 420650-9901
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 20x
- Numerical aperture (NA)
- 0.8
- Immersion
- Air
- Working distance (as recorded)
- 0.55 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room 5149.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-zeiss-lsm-880-with-airyscan; objective: 20x_air
{
"id": "20x_air",
"manufacturer": "Zeiss",
"model": "Plan-APOCHROMAT 20x/0.8",
"product_code": "420650-9901",
"magnification": 20.0,
"numerical_aperture": 0.8,
"working_distance": "0.55 mm",
"immersion": "air",
"correction": "plan_apochromat",
"afc_compatible": false,
"is_installed": true,
"url": "https://www.micro-shop.zeiss.com/zh/us/shop/objectives/420650-9901-000/Objective-Plan-Apochromat-20x-0.8-M27"
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-zeiss-lsm-880-with-airyscan--20x_air (catalogue ID, not a physical asset tag).
Zeiss · Objective
LD LCI Plan APOCHROMAT 40x/1.2 Imm Korr DIC (UV)VIS-IR
Installed - as recorded
Zeiss LSM 880 with AiryScan
Product code: 420862-9970
Recorded note: Imm Korr (multi-immersion, correction collar). Correction collar repaired during the 2026-05-13 to 2026-05-14 vendor preventive-maintenance visit (maintenance_id: maint_scope-zeiss-lsm-880-with-airyscan_20260513_preventive_maintenance); objective operational.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 40x
- Numerical aperture (NA)
- 1.2
- Immersion
- Multi-Immersion
- Working distance (as recorded)
- 0.41 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room 5149.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-zeiss-lsm-880-with-airyscan; objective: 40x_multi
{
"id": "40x_multi",
"manufacturer": "Zeiss",
"model": "LD LCI Plan APOCHROMAT 40x/1.2 Imm Korr DIC (UV)VIS-IR",
"product_code": "420862-9970",
"magnification": 40.0,
"numerical_aperture": 1.2,
"working_distance": "0.41 mm",
"immersion": "multi",
"correction": "plan_apochromat",
"afc_compatible": false,
"is_installed": true,
"specialties": [
"dic",
"ir_transmission"
],
"notes": "Imm Korr (multi-immersion, correction collar). Correction collar repaired during the 2026-05-13 to 2026-05-14 vendor preventive-maintenance visit (maintenance_id: maint_scope-zeiss-lsm-880-with-airyscan_20260513_preventive_maintenance); objective operational.",
"url": "https://www.micro-shop.zeiss.com/en/us/shop/objectives/420862-9970-790/Objective-LD-LCI-Plan-Apochromat-40x-1.2-Imm-autocorr-DIC-M27"
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-zeiss-lsm-880-with-airyscan--40x_multi (catalogue ID, not a physical asset tag).
Zeiss · Objective
C-Plan-APOCHROMAT 63x/1.4 Oil DIC UV-VIS-IR
Installed - as recorded
Zeiss LSM 880 with AiryScan
Product code: 421782-9900
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 63x
- Numerical aperture (NA)
- 1.4
- Immersion
- Oil
- Working distance (as recorded)
- 0.14 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room 5149.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-zeiss-lsm-880-with-airyscan; objective: 63x_oil
{
"id": "63x_oil",
"manufacturer": "Zeiss",
"model": "C-Plan-APOCHROMAT 63x/1.4 Oil DIC UV-VIS-IR",
"product_code": "421782-9900",
"magnification": 63.0,
"numerical_aperture": 1.4,
"working_distance": "0.14 mm",
"immersion": "oil",
"correction": "plan_apochromat",
"afc_compatible": false,
"is_installed": true,
"specialties": [
"dic",
"ir_transmission"
],
"url": "https://www.micro-shop.zeiss.com/en/us/shop/objectives/421782-9900-000/Objective-C-Plan-Apochromat-63x-1.4-Oil-DIC-M27"
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-zeiss-lsm-880-with-airyscan--63x_oil (catalogue ID, not a physical asset tag).
Zeiss · Objective
LD LCI Plan-APOCHROMAT 25x/0.8 Imm Korr DIC (UV)VIS-IR
Associated - not installed
Zeiss LSM 880 with AiryScan
Product code: 420852-9871
Recorded note: Optional objective. Imm Korr (Multi-immersion, correction collar)
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 25x
- Numerical aperture (NA)
- 0.8
- Immersion
- Multi-Immersion
- Working distance (as recorded)
- 0.57 mm at cover glass 0.17
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room 5149.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-zeiss-lsm-880-with-airyscan; objective: 25x_multi
{
"id": "25x_multi",
"manufacturer": "Zeiss",
"model": "LD LCI Plan-APOCHROMAT 25x/0.8 Imm Korr DIC (UV)VIS-IR",
"product_code": "420852-9871",
"magnification": 25.0,
"numerical_aperture": 0.8,
"working_distance": "0.57 mm at cover glass 0.17",
"immersion": "multi",
"correction": "plan_apochromat",
"afc_compatible": false,
"is_installed": false,
"specialties": [
"dic",
"ir_transmission"
],
"notes": "Optional objective. Imm Korr (Multi-immersion, correction collar)",
"url": "https://www.micro-shop.zeiss.com/en/us/shop/objectives/420852-9871-799/Objective-LD-LCI-Plan-Apochromat-25x-0.8-Imm-Corr-DIC-M27"
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-zeiss-lsm-880-with-airyscan--25x_multi (catalogue ID, not a physical asset tag).
Zeiss · Objective
C-APOCHROMAT 63x/1.2 W Korr UV-VIS-IR
Associated - not installed
Zeiss LSM 880 with AiryScan
Product code: 421787-9970
Recorded note: Optional objective. W Korr (Water immersion, correction collar)
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 63x
- Numerical aperture (NA)
- 1.2
- Immersion
- Water
- Working distance (as recorded)
- 0.28 mm at cover glass 0.17
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 5th floor, room 5149.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-zeiss-lsm-880-with-airyscan; objective: 63x_water
{
"id": "63x_water",
"manufacturer": "Zeiss",
"model": "C-APOCHROMAT 63x/1.2 W Korr UV-VIS-IR",
"product_code": "421787-9970",
"magnification": 63.0,
"numerical_aperture": 1.2,
"working_distance": "0.28 mm at cover glass 0.17",
"immersion": "water",
"correction": "apochromat",
"afc_compatible": false,
"is_installed": false,
"specialties": [
"ir_transmission"
],
"notes": "Optional objective. W Korr (Water immersion, correction collar)",
"url": "https://www.micro-shop.zeiss.com/en/us/shop/objectives/421787-9970-799/Objective-C-Apochromat-63x-1.2-W-Corr-M27"
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-zeiss-lsm-880-with-airyscan--63x_water (catalogue ID, not a physical asset tag).
Zeiss · Objective
EC Epiplan-Neofluar
Installed - as recorded
Zeiss TIRF
Product code: Not recorded
Recorded note: Pre-existing ledger record, kept as installed. The current facility OpenIRIS objective list (10x/20x/40x/63x/100x) does not include a 2.5x objective; whether it is still on the microscope is an open staff question, not a confirmed removal.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 2.5x
- Numerical aperture (NA)
- 0.06
- Immersion
- Air
- Working distance (as recorded)
- 15.1 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 2nd floor, room 2209.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-zeiss-tirf; objective: 2.5x_air
{
"id": "2.5x_air",
"manufacturer": "Zeiss",
"model": "EC Epiplan-Neofluar",
"magnification": 2.5,
"numerical_aperture": 0.06,
"working_distance": "15.1 mm",
"immersion": "air",
"correction": "plan_fluorite",
"afc_compatible": false,
"is_installed": true,
"notes": "Pre-existing ledger record, kept as installed. The current facility OpenIRIS objective list (10x/20x/40x/63x/100x) does not include a 2.5x objective; whether it is still on the microscope is an open staff question, not a confirmed removal."
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-zeiss-tirf--2.5x_air (catalogue ID, not a physical asset tag).
Zeiss · Objective
EC Plan-Neofluar 10x/0.3
Installed - as recorded
Zeiss TIRF
Product code: 420340-9901
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 10x
- Numerical aperture (NA)
- 0.3
- Immersion
- Air
- Working distance (as recorded)
- 5.2 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 2nd floor, room 2209.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-zeiss-tirf; objective: 10x_air
{
"id": "10x_air",
"manufacturer": "Zeiss",
"model": "EC Plan-Neofluar 10x/0.3",
"product_code": "420340-9901",
"magnification": 10.0,
"numerical_aperture": 0.3,
"working_distance": "5.2 mm",
"immersion": "air",
"correction": "plan_fluorite",
"is_installed": true,
"url": "https://www.micro-shop.zeiss.com/en/us/shop/objectives/420340-9901-000/Objective-EC-Plan-Neofluar-10x-0.30-M27"
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-zeiss-tirf--10x_air (catalogue ID, not a physical asset tag).
Zeiss · Objective
Plan-Apochromat 20x/0.8
Installed - as recorded
Zeiss TIRF
Product code: 420650-9901
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 20x
- Numerical aperture (NA)
- 0.8
- Immersion
- Air
- Working distance (as recorded)
- 0.55 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 2nd floor, room 2209.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-zeiss-tirf; objective: 20x_air
{
"id": "20x_air",
"manufacturer": "Zeiss",
"model": "Plan-Apochromat 20x/0.8",
"product_code": "420650-9901",
"magnification": 20.0,
"numerical_aperture": 0.8,
"working_distance": "0.55 mm",
"immersion": "air",
"correction": "plan_apochromat",
"is_installed": true,
"url": "https://www.micro-shop.zeiss.com/en/us/shop/objectives/420650-9901-000/Objective-Plan-Apochromat-20x-0.8-M27"
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-zeiss-tirf--20x_air (catalogue ID, not a physical asset tag).
Zeiss · Objective
LD Achroplan 40x/0.60 Korr Ph2
Installed - as recorded
Zeiss TIRF
Product code: 440865
Recorded note: Objective listed for this microscope in the facility OpenIRIS record; working distance cross-checked against ZEISS Axiovert 200 documentation.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 40x
- Numerical aperture (NA)
- 0.6
- Immersion
- Air
- Working distance (as recorded)
- 1.8 mm at cover glass 1.0
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 2nd floor, room 2209.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-zeiss-tirf; objective: 40x_air
{
"id": "40x_air",
"manufacturer": "Zeiss",
"model": "LD Achroplan 40x/0.60 Korr Ph2",
"product_code": "440865",
"magnification": 40.0,
"numerical_aperture": 0.6,
"working_distance": "1.8 mm at cover glass 1.0",
"immersion": "air",
"correction": "plan_achromat",
"is_installed": true,
"specialties": [
"phase",
"correction_collar"
],
"notes": "Objective listed for this microscope in the facility OpenIRIS record; working distance cross-checked against ZEISS Axiovert 200 documentation.",
"url": "https://www.zeiss.com/content/dam/rms/countries/united-states/downloads/end-of-service/inverted/inverted-axiovert-200-axiovert-200m.pdf/_jcr_content/renditions/original./inverted-axiovert-200-axiovert-200m.pdf"
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-zeiss-tirf--40x_air (catalogue ID, not a physical asset tag).
Zeiss · Objective
alpha Plan-Apochromat 63x/1.46 Oil Corr TIRF
Installed - as recorded
Zeiss TIRF
Product code: 420780-9970
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 63x
- Numerical aperture (NA)
- 1.46
- Immersion
- Oil
- Working distance (as recorded)
- 0.10 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 2nd floor, room 2209.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-zeiss-tirf; objective: 63x_oil
{
"id": "63x_oil",
"manufacturer": "Zeiss",
"model": "alpha Plan-Apochromat 63x/1.46 Oil Corr TIRF",
"product_code": "420780-9970",
"magnification": 63.0,
"numerical_aperture": 1.46,
"working_distance": "0.10 mm",
"immersion": "oil",
"correction": "plan_apochromat",
"is_installed": true,
"specialties": [
"tirf"
],
"url": "https://www.micro-shop.zeiss.com/en/pl/shop/objectives/420780-9970-000/Objective-alpha-Plan-Apochromat-63x-1.46-Oil-Corr-M27"
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-zeiss-tirf--63x_oil (catalogue ID, not a physical asset tag).
Zeiss · Objective
alpha Plan-Apochromat 100x/1.46 Oil DIC (UV) VIS-IR
Installed - as recorded
Zeiss TIRF
Product code: 420792-9800
Recorded note: Local OpenIRIS lists 420792-9800 as 100x/1.45 Oil DIC (UV) VIS-IR. The matching ZEISS 420792-9800-000 UV-VIS-IR variant specifies NA 1.46 and a structured Free Working Distance of 0.11 mm. The same ZEISS page describes FWD as 0.10 mm in prose; the explicit specification-table value is used here.
Not assessed by this catalogue
Installation status is not a serviceability check. See the microscope record and staff for current status.
- Magnification
- 100x
- Numerical aperture (NA)
- 1.46
- Immersion
- Oil
- Working distance (as recorded)
- 0.11 mm
- Availability
- Ask staff; not a loan offer
Details and source record
Recorded instrument location: BioCity, 2nd floor, room 2209.
This objective is associated with the microscope record; that does not mean it is available to move or borrow. Identical models in separate records may represent different physical objectives.
Instrument record:
Microscope record: scope-zeiss-tirf; objective: 100x_oil
{
"id": "100x_oil",
"manufacturer": "Zeiss",
"model": "alpha Plan-Apochromat 100x/1.46 Oil DIC (UV) VIS-IR",
"product_code": "420792-9800",
"magnification": 100.0,
"numerical_aperture": 1.46,
"working_distance": "0.11 mm",
"immersion": "oil",
"correction": "plan_apochromat",
"is_installed": true,
"specialties": [
"tirf"
],
"notes": "Local OpenIRIS lists 420792-9800 as 100x/1.45 Oil DIC (UV) VIS-IR. The matching ZEISS 420792-9800-000 UV-VIS-IR variant specifies NA 1.46 and a structured Free Working Distance of 0.11 mm. The same ZEISS page describes FWD as 0.10 mm in prose; the explicit specification-table value is used here.",
"url": "https://www.micro-shop.zeiss.com/en/us/shop/objectives/420792-9800-000/Objective-Plan-Apochromat-100x-1.46-Oil-DIC-M27"
}
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: objective-scope-zeiss-tirf--100x_oil (catalogue ID, not a physical asset tag).
ZEISS · Objective
LD Plan-NEOFLUAR 63x/0.75 Ph2 Korr
Spare-pool listing
Product code: 441371-9970
Not assessed
No problem noted in the source; this is not a serviceability check.
- Magnification
- 63x
- Numerical aperture (NA)
- 0.75
- Immersion
- Dry
- Working distance (mm)
- 0,75
- Mounting (source group)
- Thread M27/0.75
- Availability
- Availability unconfirmed
Details and enquiry
Storage: Not recorded; ask staff.
Quantity: Not verified.
Microscope compatibility: Not verified.
Original source, page 1:
ZEISS Thread M27/0.75 441371-9970 LD Plan-NEOFLUAR 63x/0.75 Ph2 Korr WD 0,75
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: pool-zeiss-441371-9970 (catalogue ID, not a physical asset tag).
ZEISS · Objective
Plan-NEOFLUAR 40x/0.75
Spare-pool listing
Product code: 44 03 50
Not assessed
No problem noted in the source; this is not a serviceability check.
- Magnification
- 40x
- Numerical aperture (NA)
- 0.75
- Immersion
- Dry
- Working distance (mm)
- 0.71
- Mounting (source group)
- Thread M27/0.75
- Availability
- Availability unconfirmed
Details and enquiry
Storage: Not recorded; ask staff.
Quantity: Not verified.
Microscope compatibility: Not verified.
Original source, page 1:
ZEISS Thread M27/0.75 44 03 50 Plan-NEOFLUAR 40x/0.75 WD 0.71
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: pool-zeiss-44-03-50 (catalogue ID, not a physical asset tag).
ZEISS · Objective
LD Plan-NEOFLUAR 40x/0.6 Ph2 Korr
Spare-pool listing
Product code: 441351-9970
Not assessed
No problem noted in the source; this is not a serviceability check.
- Magnification
- 40x
- Numerical aperture (NA)
- 0.6
- Immersion
- Dry
- Working distance (mm)
- 2,9 at cover glass 0,75
- Mounting (source group)
- Thread M27/0.75
- Availability
- Availability unconfirmed
Details and enquiry
Storage: Not recorded; ask staff.
Quantity: Not verified.
Microscope compatibility: Not verified.
Original source, page 1:
ZEISS Thread M27/0.75 441351-9970 LD Plan-NEOFLUAR 40x/0.6 Ph2 Korr WD 2,9 at cover glass 0,75
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: pool-zeiss-441351-9970 (catalogue ID, not a physical asset tag).
ZEISS · Objective
Plan-APOCHROMAT 20x/0.8
Spare-pool listing
Product code: 420650-9901
Not assessed
No problem noted in the source; this is not a serviceability check.
- Magnification
- 20x
- Numerical aperture (NA)
- 0.8
- Immersion
- Dry
- Working distance (mm)
- 0.55
- Mounting (source group)
- Thread M27/0.75
- Availability
- Availability unconfirmed
Details and enquiry
Storage: Not recorded; ask staff.
Quantity: Not verified.
Microscope compatibility: Not verified.
Original source, page 1:
ZEISS Thread M27/0.75 420650-9901 Plan-APOCHROMAT 20x/0.8 WD 0.55
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: pool-zeiss-420650-9901 (catalogue ID, not a physical asset tag).
ZEISS · Objective
LD A-Plan 20x/0.30 Ph1 Var1
Spare-pool listing
Product code: 1006-592
Not assessed
No problem noted in the source; this is not a serviceability check.
- Magnification
- 20x
- Numerical aperture (NA)
- 0.30
- Immersion
- Dry
- Working distance (mm)
- 4,3
- Mounting (source group)
- Thread M27/0.75
- Availability
- Availability unconfirmed
Details and enquiry
Storage: Not recorded; ask staff.
Quantity: Not verified.
Microscope compatibility: Not verified.
Original source, page 1:
ZEISS Thread M27/0.75 1006-592 LD A-Plan 20x/0.30 Ph1 Var1 WD 4,3
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: pool-zeiss-1006-592 (catalogue ID, not a physical asset tag).
ZEISS · Objective
Plan-NEOFLUAR 10x/0.30
Spare-pool listing
Product code: 44 03 30
Not assessed
No problem noted in the source; this is not a serviceability check.
- Magnification
- 10x
- Numerical aperture (NA)
- 0.30
- Immersion
- Dry
- Working distance (mm)
- 5,2
- Mounting (source group)
- Thread M27/0.75
- Availability
- Availability unconfirmed
Details and enquiry
Storage: Not recorded; ask staff.
Quantity: Not verified.
Microscope compatibility: Not verified.
Original source, page 1:
ZEISS Thread M27/0.75 44 03 30 Plan-NEOFLUAR 10x/0.30 WD 5,2
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: pool-zeiss-44-03-30 (catalogue ID, not a physical asset tag).
ZEISS · Objective
EC Plan-NEOFLUAR 10x/0.3
Spare-pool listing
Product code: 420340-9901
Not assessed
No problem noted in the source; this is not a serviceability check.
- Magnification
- 10x
- Numerical aperture (NA)
- 0.3
- Immersion
- Dry
- Working distance (mm)
- 5,2
- Mounting (source group)
- Thread M27/0.75
- Availability
- Availability unconfirmed
Details and enquiry
Storage: Not recorded; ask staff.
Quantity: Not verified.
Microscope compatibility: Not verified.
Original source, page 1:
ZEISS Thread M27/0.75 420340-9901 EC Plan-NEOFLUAR 10x/0.3 WD 5,2
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: pool-zeiss-420340-9901 (catalogue ID, not a physical asset tag).
ZEISS · Objective
EC Epiplan-NEOFLUAR 2.5x/0.06 HD
Spare-pool listing
Product code: 422320-9960
Not assessed
No problem noted in the source; this is not a serviceability check.
- Magnification
- 2.5x
- Numerical aperture (NA)
- 0.06
- Immersion
- Dry
- Working distance (mm)
- 15,1
- Mounting (source group)
- Thread M27/0.75
- Availability
- Availability unconfirmed
Details and enquiry
Storage: Not recorded; ask staff.
Quantity: Not verified.
Microscope compatibility: Not verified.
Original source, page 1:
ZEISS Thread M27/0.75 422320-9960 EC Epiplan-NEOFLUAR 2.5x/0.06 HD WD 15,1
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: pool-zeiss-422320-9960 (catalogue ID, not a physical asset tag).
ZEISS · Objective
EC Plan-NEOFLUAR 1x/0.025
Spare-pool listing
Product code: 420300-9900
Not assessed
No problem noted in the source; this is not a serviceability check.
- Magnification
- 1x
- Numerical aperture (NA)
- 0.025
- Immersion
- Dry
- Working distance (mm)
- 2,9
- Mounting (source group)
- Thread M27/0.75
- Availability
- Availability unconfirmed
Details and enquiry
Storage: Not recorded; ask staff.
Quantity: Not verified.
Microscope compatibility: Not verified.
Original source, page 1:
ZEISS Thread M27/0.75 420300-9900 EC Plan-NEOFLUAR 1x/0.025 WD 2,9
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: pool-zeiss-420300-9900 (catalogue ID, not a physical asset tag).
ZEISS · Objective
C-APOCHROMAT 63x/1.2 W Korr UV-VIS-IR
Spare-pool listing
Product code: 421787–9970
Not assessed
No problem noted in the source; this is not a serviceability check.
- Magnification
- 63x
- Numerical aperture (NA)
- 1.2
- Immersion
- Water immersion
- Working distance (mm)
- 0.28
- Mounting (source group)
- Thread M27/0.75
- Availability
- Availability unconfirmed
Details and enquiry
Storage: Not recorded; ask staff.
Quantity: Not verified.
Microscope compatibility: Not verified.
Original source, page 1:
ZEISS Thread M27/0.75 421787–9970 C-APOCHROMAT 63x/1.2 W Korr UV-VIS-IR WD 0.28
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: pool-zeiss-421787-9970 (catalogue ID, not a physical asset tag).
ZEISS · Objective
LD C-APOCHROMAT 63x/1.15 W Korr UV-VIS-IR
Spare-pool listing
Product code: 421887–9970
Not assessed
No problem noted in the source; this is not a serviceability check.
- Magnification
- 63x
- Numerical aperture (NA)
- 1.15
- Immersion
- Water immersion
- Working distance (mm)
- 0,60
- Mounting (source group)
- Thread M27/0.75
- Availability
- Availability unconfirmed
Details and enquiry
Storage: Not recorded; ask staff.
Quantity: Not verified.
Microscope compatibility: Not verified.
Original source, page 1:
ZEISS Thread M27/0.75 421887–9970 LD C-APOCHROMAT 63x/1.15 W Korr UV-VIS-IR WD 0,60
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: pool-zeiss-421887-9970 (catalogue ID, not a physical asset tag).
ZEISS · Objective
Plan-APOCHROMAT 100x/1.4 Oil DIC
Spare-pool listing
Product code: 440782-9902
Not assessed
No problem noted in the source; this is not a serviceability check.
- Magnification
- 100x
- Numerical aperture (NA)
- 1.4
- Immersion
- Oil immersion
- Working distance (mm)
- 0,17
- Mounting (source group)
- Thread M27/0.75
- Availability
- Availability unconfirmed
Details and enquiry
Storage: Not recorded; ask staff.
Quantity: Not verified.
Microscope compatibility: Not verified.
Original source, page 1:
ZEISS Thread M27/0.75 440782-9902 Plan-APOCHROMAT 100x/1.4 Oil DIC WD 0,17
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: pool-zeiss-440782-9902 (catalogue ID, not a physical asset tag).
ZEISS · Objective
Plan-NEOFLUAR 63x/1.25 Oil PH3
Spare-pool listing
Product code: 44 04 61
Not assessed
No problem noted in the source; this is not a serviceability check.
- Magnification
- 63x
- Numerical aperture (NA)
- 1.25
- Immersion
- Oil immersion
- Working distance (mm)
- 0,10
- Mounting (source group)
- Thread M27/0.75
- Availability
- Availability unconfirmed
Details and enquiry
Storage: Not recorded; ask staff.
Quantity: Not verified.
Microscope compatibility: Not verified.
Original source, page 1:
ZEISS Thread M27/0.75 44 04 61 Plan-NEOFLUAR 63x/1.25 Oil PH3 WD 0,10
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: pool-zeiss-44-04-61 (catalogue ID, not a physical asset tag).
ZEISS · Objective
Plan-APOCHROMAT 63x/1.4 Oil
Spare-pool listing
Product code: 44 07 60 (1100-829)
Not assessed
No problem noted in the source; this is not a serviceability check.
- Magnification
- 63x
- Numerical aperture (NA)
- 1.4
- Immersion
- Oil immersion
- Working distance (mm)
- 0,19
- Mounting (source group)
- Thread M27/0.75
- Availability
- Availability unconfirmed
Details and enquiry
Storage: Not recorded; ask staff.
Quantity: Not verified.
Microscope compatibility: Not verified.
Original source, page 1:
ZEISS Thread M27/0.75 44 07 60 (1100-829) Plan-APOCHROMAT 63x/1.4 Oil WD 0,19
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: pool-zeiss-44-07-60 (catalogue ID, not a physical asset tag).
ZEISS · Objective
Plan-APOCHROMAT 63x/1.4 Oil DIC
Spare-pool listing
Product code: 440762-9904
Not assessed
No problem noted in the source; this is not a serviceability check.
- Magnification
- 63x
- Numerical aperture (NA)
- 1.4
- Immersion
- Oil immersion
- Working distance (mm)
- 0,19
- Mounting (source group)
- Thread M27/0.75
- Availability
- Availability unconfirmed
Details and enquiry
Storage: Not recorded; ask staff.
Quantity: Not verified.
Microscope compatibility: Not verified.
Original source, page 1:
ZEISS Thread M27/0.75 440762-9904 Plan-APOCHROMAT 63x/1.4 Oil DIC WD 0,19
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: pool-zeiss-440762-9904 (catalogue ID, not a physical asset tag).
ZEISS · Objective
Plan-NEOFLUAR 40x/1.3 Oil
Spare-pool listing
Product code: 1022-818 (1080-398)
Reported problem: Inner lenses with droplets!
Do not use until staff have reviewed the reported problem.
- Magnification
- 40x
- Numerical aperture (NA)
- 1.3
- Immersion
- Oil immersion
- Working distance (mm)
- 0,21
- Mounting (source group)
- Thread M27/0.75
- Availability
- Availability unconfirmed
Details and enquiry
Storage: Not recorded; ask staff.
Quantity: Not verified.
Microscope compatibility: Not verified.
Original source, page 1:
ZEISS Thread M27/0.75 1022-818 (1080-398) Plan-NEOFLUAR 40x/1.3 Oil WD 0,21 Inner lenses with droplets!
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: pool-zeiss-1022-818 (catalogue ID, not a physical asset tag).
ZEISS · Objective
LD LCI Plan-APOCHROMAT 25x/0.8 Imm Korr DIC (UV)-VIS-IR
Spare-pool listing
Product code: 420852-9871
Not assessed
No problem noted in the source; this is not a serviceability check.
- Magnification
- 25x
- Numerical aperture (NA)
- 0.8
- Immersion
- Universal immersion
- Working distance (mm)
- 0,57
- Mounting (source group)
- Thread M27/0.75
- Availability
- Availability unconfirmed
Details and enquiry
Storage: Not recorded; ask staff.
Quantity: Not verified.
Microscope compatibility: Not verified.
Original source, page 1:
ZEISS Thread M27/0.75 420852-9871 LD LCI Plan-APOCHROMAT 25x/0.8 Imm WD 0,57 Korr DIC (UV)-VIS-IR
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: pool-zeiss-420852-9871 (catalogue ID, not a physical asset tag).
ZEISS · Calibration item
APO Calibration LSM (SN 53811)
Spare-pool listing
Product code: 420639-9000-700
Not assessed
No problem noted in the source; this is not a serviceability check.
- Magnification
- Not recorded
- Numerical aperture (NA)
- Not recorded
- Immersion
- Not recorded
- Working distance (mm)
- Not recorded
- Mounting (source group)
- Thread M27/0.75
- Availability
- Availability unconfirmed
Details and enquiry
Storage: Not recorded; ask staff.
Quantity: Not verified.
Microscope compatibility: Not verified.
Original source, page 1:
ZEISS Thread M27/0.75 420639-9000-700 APO Calibration LSM (SN 53811)
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: pool-zeiss-420639-9000-700 (catalogue ID, not a physical asset tag).
Leica · Objective
HC Plan Apo 20x/0.70 PH2
Spare-pool listing
Product code: 506170
Not assessed
No problem noted in the source; this is not a serviceability check.
- Magnification
- 20x
- Numerical aperture (NA)
- 0.70
- Immersion
- Dry
- Working distance (mm)
- 0.59
- Working-distance verification
- The pool source leaves WD blank; the exact 506170 objective is independently documented with a 0.59 mm working distance. Evidence: University of Bristol Confocal 9 technical specification.
- Mounting (source group)
- Thread M25
- Availability
- Availability unconfirmed
Details and enquiry
Storage: Not recorded; ask staff.
Quantity: Not verified.
Microscope compatibility: Not verified.
Original source, page 2:
Leica Thread M25 506170 HC Plan Apo 20x/0.70 PH2 WD
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: pool-leica-506170 (catalogue ID, not a physical asset tag).
Leica · Objective
L 20x/0.50 W U-V-I
Spare-pool listing
Product code: 506147
Not assessed
No problem noted in the source; this is not a serviceability check.
- Magnification
- 20x
- Numerical aperture (NA)
- 0.50
- Immersion
- Water dipping
- Working distance (mm)
- 3,5
- Mounting (source group)
- Thread M25
- Availability
- Availability unconfirmed
Details and enquiry
Storage: Not recorded; ask staff.
Quantity: Not verified.
Microscope compatibility: Not verified.
Original source, page 2:
Leica Thread M25 506147 L 20x/0.50 W U-V-I WD 3,5
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: pool-leica-506147 (catalogue ID, not a physical asset tag).
Leica · Objective
L 40x/0.80 W U-V-I
Spare-pool listing
Product code: 506155
Not assessed
No problem noted in the source; this is not a serviceability check.
- Magnification
- 40x
- Numerical aperture (NA)
- 0.80
- Immersion
- Water dipping
- Working distance (mm)
- 3,3
- Mounting (source group)
- Thread M25
- Availability
- Availability unconfirmed
Details and enquiry
Storage: Not recorded; ask staff.
Quantity: Not verified.
Microscope compatibility: Not verified.
Original source, page 2:
Leica Thread M25 506155 L 40x/0.80 W U-V-I WD 3,3
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: pool-leica-506155 (catalogue ID, not a physical asset tag).
Leica · Objective
PL APO 63x/1.20 W CORR
Spare-pool listing
Product code: 506131
Not assessed
No problem noted in the source; this is not a serviceability check.
- Magnification
- 63x
- Numerical aperture (NA)
- 1.20
- Immersion
- Water immersion
- Working distance (mm)
- 0,22
- Mounting (source group)
- Thread M25
- Availability
- Availability unconfirmed
Details and enquiry
Storage: Not recorded; ask staff.
Quantity: Not verified.
Microscope compatibility: Not verified.
Original source, page 2:
Leica Thread M25 506131 PL APO 63x/1.20 W CORR WD 0,22
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: pool-leica-506131 (catalogue ID, not a physical asset tag).
Leica · Objective
HCX PL APO 63x/1.20 W CORR CS
Spare-pool listing
Product code: 506279
Not assessed
No problem noted in the source; this is not a serviceability check.
- Magnification
- 63x
- Numerical aperture (NA)
- 1.20
- Immersion
- Water immersion
- Working distance (mm)
- 0,22
- Mounting (source group)
- Thread M25
- Availability
- Availability unconfirmed
Details and enquiry
Storage: Not recorded; ask staff.
Quantity: Not verified.
Microscope compatibility: Not verified.
Original source, page 2:
Leica Thread M25 506279 HCX PL APO 63x/1.20 W CORR CS WD 0,22
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: pool-leica-506279 (catalogue ID, not a physical asset tag).
Leica · Objective
PL FLUOTAR 25x/0.75 OIL
Spare-pool listing
Product code: 506006
Not assessed
No problem noted in the source; this is not a serviceability check.
- Magnification
- 25x
- Numerical aperture (NA)
- 0.75
- Immersion
- Oil immersion
- Working distance (mm)
- 0,18
- Mounting (source group)
- Thread M25
- Availability
- Availability unconfirmed
Details and enquiry
Storage: Not recorded; ask staff.
Quantity: Not verified.
Microscope compatibility: Not verified.
Original source, page 2:
Leica Thread M25 506006 PL FLUOTAR 25x/0.75 OIL WD 0,18
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: pool-leica-506006 (catalogue ID, not a physical asset tag).
Leica · Objective
PL FLUOTAR 40x/1.00-0.50 OIL
Spare-pool listing
Product code: 506007
Reported problem: iris diaphragm stuck
Do not use until staff have reviewed the reported problem.
- Magnification
- 40x
- Numerical aperture (NA)
- 1.00-0.50
- Immersion
- Oil immersion
- Working distance (mm)
- 0,08
- Mounting (source group)
- Thread M25
- Availability
- Availability unconfirmed
Details and enquiry
Storage: Not recorded; ask staff.
Quantity: Not verified.
Microscope compatibility: Not verified.
Original source, page 2:
Leica Thread M25 506007 PL FLUOTAR 40x/1.00-0.50 OIL WD 0,08 iris diaphragm stuck
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: pool-leica-506007 (catalogue ID, not a physical asset tag).
Leica · Objective
PL APO 63x/1.32 OIL PH3
Spare-pool listing
Product code: 506082
Reported problem: problem with UV transmission
Do not use until staff have reviewed the reported problem.
- Magnification
- 63x
- Numerical aperture (NA)
- 1.32
- Immersion
- Oil immersion
- Working distance (mm)
- 0.07
- Working-distance verification
- The pool source records WD 0,17, but the exact 506082 objective is independently documented with WD 0.07 mm; 0.17 mm is the cover-glass specification. Evidence: University of Bristol Wide-field imaging system 1 technical specification.
- Mounting (source group)
- Thread M25
- Availability
- Availability unconfirmed
Details and enquiry
Storage: Not recorded; ask staff.
Quantity: Not verified.
Microscope compatibility: Not verified.
Original source, page 2:
Leica Thread M25 506082 PL APO 63x/1.32 OIL PH3 WD 0,17 problem with UV transmission
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: pool-leica-506082 (catalogue ID, not a physical asset tag).
Leica · Objective
HCX PL APO 63x/1.40-0.60 OIL CS
Spare-pool listing
Product code: 506188
Not assessed
No problem noted in the source; this is not a serviceability check.
- Magnification
- 63x
- Numerical aperture (NA)
- 1.40-0.60
- Immersion
- Oil immersion
- Working distance (mm)
- 0,14
- Mounting (source group)
- Thread M25
- Availability
- Availability unconfirmed
Details and enquiry
Storage: Not recorded; ask staff.
Quantity: Not verified.
Microscope compatibility: Not verified.
Original source, page 2:
Leica Thread M25 506188 HCX PL APO 63x/1.40-0.60 OIL CS WD 0,14
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: pool-leica-506188 (catalogue ID, not a physical asset tag).
Leica · Objective
PL APO 100x/1.40-0.70 OIL
Spare-pool listing
Product code: 506316
Reported problem: iris diaphragm stuck
Do not use until staff have reviewed the reported problem.
- Magnification
- 100x
- Numerical aperture (NA)
- 1.40-0.70
- Immersion
- Oil immersion
- Working distance (mm)
- 0,09
- Mounting (source group)
- Thread M25
- Availability
- Availability unconfirmed
Details and enquiry
Storage: Not recorded; ask staff.
Quantity: Not verified.
Microscope compatibility: Not verified.
Original source, page 2:
Leica Thread M25 506316 PL APO 100x/1.40-0.70 OIL WD 0,09 iris diaphragm stuck
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: pool-leica-506316 (catalogue ID, not a physical asset tag).
Leica · Objective
PL FLUOTAR 16x/0.50 IMM
Spare-pool listing
Product code: 506002
Not assessed
No problem noted in the source; this is not a serviceability check.
- Magnification
- 16x
- Numerical aperture (NA)
- 0.50
- Immersion
- Universal immersion
- Working distance (mm)
- 0,15
- Mounting (source group)
- Thread M25
- Availability
- Availability unconfirmed
Details and enquiry
Storage: Not recorded; ask staff.
Quantity: Not verified.
Microscope compatibility: Not verified.
Original source, page 2:
Leica Thread M25 506002 PL FLUOTAR 16x/0.50 IMM WD 0,15
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: pool-leica-506002 (catalogue ID, not a physical asset tag).
OLYMPUS, Japan · Objective
A10x/0.25
Spare-pool listing
Product code: Not recorded
Not assessed
No problem noted in the source; this is not a serviceability check.
- Magnification
- 10x
- Numerical aperture (NA)
- 0.25
- Immersion
- Not recorded
- Working distance (mm)
- Not recorded
- Mounting (source group)
- thread 20 (as written)
- Availability
- Availability unconfirmed
Details and enquiry
Storage: Not recorded; ask staff.
Quantity: Not verified.
Microscope compatibility: Not verified.
Original source, page 2:
OLYMPUS, Japan -tubus length 160, thread 20 A10x/0.25
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: pool-olympus-a10x-0-25 (catalogue ID, not a physical asset tag).
OLYMPUS, Japan · Objective
LWD CDPlan 20x/0.40 PL
Spare-pool listing
Product code: Not recorded
Reported problem: correction collar stuck
Do not use until staff have reviewed the reported problem.
- Magnification
- 20x
- Numerical aperture (NA)
- 0.40
- Immersion
- Not recorded
- Working distance (mm)
- Not recorded
- Mounting (source group)
- thread 20 (as written)
- Availability
- Availability unconfirmed
Details and enquiry
Storage: Not recorded; ask staff.
Quantity: Not verified.
Microscope compatibility: Not verified.
Original source, page 2:
OLYMPUS, Japan -tubus length 160, thread 20 LWD CDPlan 20x/0.40 PL phase, correction collar stuck
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: pool-olympus-lwd-cdplan-20x-0-40-pl (catalogue ID, not a physical asset tag).
OLYMPUS, Japan · Objective
LWD CDPlan 40x/0.55 PL
Spare-pool listing
Product code: Not recorded
Reported problem: correction collar stuck
Do not use until staff have reviewed the reported problem.
- Magnification
- 40x
- Numerical aperture (NA)
- 0.55
- Immersion
- Not recorded
- Working distance (mm)
- Not recorded
- Mounting (source group)
- thread 20 (as written)
- Availability
- Availability unconfirmed
Details and enquiry
Storage: Not recorded; ask staff.
Quantity: Not verified.
Microscope compatibility: Not verified.
Original source, page 2:
OLYMPUS, Japan -tubus length 160, thread 20 LWD CDPlan 40x/0.55 PL phase, correction collar stuck
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: pool-olympus-lwd-cdplan-40x-0-55-pl (catalogue ID, not a physical asset tag).
IncuCyte by ESSEN BIOSCIENCE · Objective
10x/0.30
Spare-pool listing
Product code: 4628
Reported unusable: LENSES TOTALLY RUINED!
Recorded as unusable. Not offered for imaging.
- Magnification
- 10x
- Numerical aperture (NA)
- 0.30
- Immersion
- Not recorded
- Working distance (mm)
- Not recorded
- Mounting (source group)
- thread -23 (as written)
- Availability
- Availability unconfirmed
Details and enquiry
Storage: Not recorded; ask staff.
Quantity: Not verified.
Microscope compatibility: Not verified.
Original source, page 2:
IncuCyte by ESSEN BIOSCIENCE -thread -23 4628 10x/0.30 LENSES TOTALLY RUINED!
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: pool-incucyte-4628 (catalogue ID, not a physical asset tag).
IncuCyte by ESSEN BIOSCIENCE · Objective
20x/0.45
Spare-pool listing
Product code: 4629
Reported problem: LENSES IN POOR CONDITION!
Do not use until staff have reviewed the reported problem.
- Magnification
- 20x
- Numerical aperture (NA)
- 0.45
- Immersion
- Not recorded
- Working distance (mm)
- Not recorded
- Mounting (source group)
- thread -23 (as written)
- Availability
- Availability unconfirmed
Details and enquiry
Storage: Not recorded; ask staff.
Quantity: Not verified.
Microscope compatibility: Not verified.
Original source, page 2:
IncuCyte by ESSEN BIOSCIENCE -thread -23 4629 20x/0.45 LENSES IN POOR CONDITION!
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: pool-incucyte-4629 (catalogue ID, not a physical asset tag).
Nikon, Japan · Objective
Plan Fluo 4x/0.13 OFN 25
Spare-pool listing
Product code: MRH 00041
Not assessed
No problem noted in the source; this is not a serviceability check.
- Magnification
- 4x
- Numerical aperture (NA)
- 0.13
- Immersion
- Not recorded
- Working distance (mm)
- 17,2
- Mounting (source group)
- Not recorded
- Availability
- Availability unconfirmed
Details and enquiry
Storage: Not recorded; ask staff.
Quantity: Not verified.
Microscope compatibility: Not verified.
Original source, page 2:
Nikon, Japan MRH 00041 Plan Fluo 4x/0.13 OFN 25 WD 17,2
Copying an enquiry does not send anything; you can edit it before contacting staff. Record ID: pool-nikon-mrh-00041 (catalogue ID, not a physical asset tag).
Sources, units and limitations
Microscope entries come from their existing objective records rather than being copied into the spare pool. Explicit installed/not-installed flags are preserved; missing flags remain unconfirmed. Retired-instrument associations are historical, not current locations or spare-stock declarations.
Pool source: ZEISSThread M27.docx, compiled by Jari Korhonen. Date as written: 020426 (date format not yet confirmed). Original pool working-distance values are preserved verbatim; their confirmed unit is mm. Where an exact product-code check establishes a corrected or previously missing working distance, the catalogue shows that value separately with its evidence and keeps the original source text in Details. Microscope working distances retain their own recorded units. A catalogue record is not a verified count of physical copies.
Spare records are not added to the Methods Generator or Virtual Microscope. This combined catalogue does not change either tool's installed-hardware data.